1.
Appl Radiat Isot ; 199: 110874, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37285758

RESUMO

The objective of this work was to investigate the luminescent properties of CaSO4:Mn synthesized by slow evaporation route. The crystalline structure, morphology, thermal and optical properties of the phosphors were characterized by X-ray diffraction analysis (XRD), Scanning electron microscopy (SEM), photoluminescence (PL) and thermogravimetric analysis (TGA). Moreover, using thermoluminescence (TL) and optically stimulated luminescence (OSL) techniques, the dosimetric properties of the phosphors, such as emission spectra, glow curve reproducibility, dose-response linearity, fading of the luminescent signal, variation of the TL intensity with the heating rate, OSL decay curves, correlation between TL and OSL emissions and minimum detectable dose (MDD) were comprehensively investigated. For dosimetric analyses, the samples were irradiated with doses from 169 mGy to 10 Gy. The emission band fits with the characteristic line of the Mn2+ emission features, ascribed to 6A1→4T1 transition. CaSO4:Mn pellets present a TL glow curve with a single typical peak centered around 494 nm, an OSL decay curve with predominance of a fast decay component, and a MDD on the order of mGy. The luminescent signals showed to be linear and reproducible in the studied dose range. The trapping centers located between 0.83 eV and 1.07 eV were revealed for different heating rates in the TL study. The high TL sensitivity of CaSO4:Mn was proven when comparing with commercially available dosimeters. The luminescent signals exhibit a smaller fading than described in the literature for CaSO4:Mn produced by other methods.

2.
Appl Radiat Isot ; 85: 11-3, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24362457

RESUMO

(90)Sr+(90)Y clinical applicators are used for brachytherapy in Brazilian clinics even though they are not manufactured anymore. Such sources must be calibrated periodically, and one of the calibration methods in use is ionometry with extrapolation ionization chambers. (90)Sr+(90)Y clinical applicators were calibrated using an extrapolation minichamber developed at the Calibration Laboratory at IPEN. The obtained results agree satisfactorily with the data provided in calibration certificates of the sources.


Assuntos
Braquiterapia/instrumentação , Braquiterapia/normas , Radiometria/instrumentação , Radiometria/normas , Radioisótopos de Estrôncio/administração & dosagem , Radioisótopos de Ítrio/administração & dosagem , Partículas beta/uso terapêutico , Brasil , Calibragem/normas , Oftalmopatias/radioterapia , Humanos , Dosagem Radioterapêutica , Dermatopatias/radioterapia , Radioisótopos de Estrôncio/normas , Radioisótopos de Estrôncio/uso terapêutico , Radioisótopos de Ítrio/normas , Radioisótopos de Ítrio/uso terapêutico
3.
Appl Radiat Isot ; 70(4): 790-3, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22304964

RESUMO

Clinical applicators are used in brachytherapy to treat superficial lesions of skin and eye. They should be periodically calibrated according to quality control programs and international recommendations. Thin CaSO(4):Dy thermoluminescent dosimeters were used to calibrate various applicators with a dermatological applicator as a reference. The obtained absorbed dose rates were compared with those quoted in their calibration certificates. Depth-dose curves were constructed for all the applicators. A mail dosimetry system was developed for calibration of clinical applicators.


Assuntos
Radioisótopos de Estrôncio , Dosimetria Termoluminescente/normas , Itérbio , Braquiterapia/métodos , Braquiterapia/normas , Sulfato de Cálcio , Calibragem , Humanos , Radioisótopos
4.
Appl Radiat Isot ; 70(2): 388-91, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22055844

RESUMO

Two secondary standard systems of beta radiation were used to calibrate a PTW extrapolation chamber Model 23391. Three (90)Sr+(90)Y sources of different activities were used in this calibration procedure. Medium-term stability of the response of the chamber was also studied. The calibration was performed with and without field-flattening filters. The relative standard deviation of the obtained calibration factors was 8.3% for the aluminum collecting electrode and 4.1% for the graphite collecting electrode.


Assuntos
Radiometria/métodos , Radioisótopos de Estrôncio/normas , Radioisótopos de Ítrio/normas , Alumínio , Partículas beta , Calibragem , Eletrodos , Filtração/instrumentação , Grafite , Radiometria/normas , Reprodutibilidade dos Testes