Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Crit Ultrasound J ; 4(1): 2, 2012 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-22883311

RESUMO

BACKGROUND: Recent studies support high success rates after a short learning period of ultrasound IV technique, and increased patient and provider satisfaction when using ultrasound as an adjunct to peripheral IV placement. No study to date has addressed the efficacy for instructing ultrasound-naive providers. We studied the introduction of ultrasound to the teaching technique of peripheral IV insertion on first- and second-year medical students. METHODS: This was a prospective, randomized, and controlled trial. A total of 69 medical students were randomly assigned to the control group with a classic, landmark-based approach (n = 36) or the real-time ultrasound-guided group (n = 33). Both groups observed a 20-min tutorial on IV placement using both techniques and then attempted vein cannulation. Students were given a survey to report their results and observations by a 10-cm visual analog scale. The survey response rate was 100%. RESULTS: In the two groups, 73.9% stated that they attempted an IV previously, and 63.7% of students had used an ultrasound machine prior to the study. None had used ultrasound for IV access prior to our session. The average number of attempts at cannulation was 1.42 in either group. There was no difference between the control and ultrasound groups in terms of number of attempts (p = 0.31). In both groups, 66.7% of learners were able to cannulate in one attempt, 21.7% in two attempts, and 11.6% in three attempts. The study group commented that they felt they gained more knowledge from the experience (p < 0.005) and that it was easier with ultrasound guidance (p < 0.005). CONCLUSION: Medical students feel they learn more when using ultrasound after a 20-min tutorial to place IVs and cannulation of the vein feels easier. Success rates are comparable between the traditional and ultrasound teaching approaches.

2.
J Emerg Med ; 41(6): 658-60, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21820258

RESUMO

BACKGROUND: Massive pulmonary embolism (PE) is a common consideration in unstable patients presenting to the emergency department (ED) with chest pain, dyspnea, or cardiac arrest. It is a potentially lethal condition necessitating prompt recognition and aggressive management. Conventional diagnostic modalities in the ED, including chest computed tomography angiography and ventilation-perfusion scanning, require the unstable patient to leave the department, and raise concerns over renal injury. Several case reports document findings of massive PE on echocardiography performed in the ED; however, none was performed, interpreted, and acted upon in the form of thrombolytic therapy by an emergency physician without the additional benefit of a cardiologist's interpretation or a confirmatory imaging study. OBJECTIVE: We present a case that illustrates the utility of ED focused bedside echocardiography in suspected massive PE and briefly review direct and indirect ultrasound findings of acute PE. CASE REPORT: A case of massive PE in a 61-year-old woman is reported. In this patient with marked dyspnea, progressive hemodynamic instability, and contraindications to definitive imaging, ED focused bedside echocardiography provided valuable information that strongly suggested the diagnosis and led to alteplase administration. To our knowledge, this case represents the first report of thrombolytic therapy administration for acute massive PE based solely on clinical presentation and an emergency physician-performed bedside echocardiogram. CONCLUSION: In the hands of an experienced emergency physician ultrasonographer, ED focused bedside echocardiography provides a safe, rapid, and non-invasive diagnostic adjunct for evaluation of the patient suspected of having massive PE.


Assuntos
Serviço Hospitalar de Emergência , Sistemas Automatizados de Assistência Junto ao Leito , Embolia Pulmonar/diagnóstico por imagem , Doença Aguda , Dor no Peito/diagnóstico , Feminino , Humanos , Pessoa de Meia-Idade , Ultrassonografia
3.
Emerg Med Clin North Am ; 29(3): 553-67, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21782074

RESUMO

The emergency medicine (EM) specialist has a wide-ranging armamentarium of imaging modalities available for use in the patient with genitourinary complaints. This article covers the various imaging options, with a discussion of the advantages and disadvantages of each of these different modalities. Special emphasis is placed on point-of-care EM ultrasound performed by the EM specialist at the patient bedside.


Assuntos
Diagnóstico por Imagem/métodos , Técnicas de Diagnóstico Urológico , Serviço Hospitalar de Emergência , Doenças Urogenitais Femininas/diagnóstico , Doenças Urogenitais Masculinas/diagnóstico , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes
4.
Acad Emerg Med ; 16(5): 429-35, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19388924

RESUMO

OBJECTIVES: In this study, an endovaginal ultrasound (US) task trainer was combined with a high-fidelity US mannequin to create a hybrid simulation model. In a scenario depicting a patient with ectopic pregnancy and hemorrhagic shock, this model was compared with a standard high-fidelity simulation during training sessions with emergency medicine (EM) residents. The authors hypothesized that use of the hybrid model would increase both the residents' self-reported educational experience and the faculty's self-reported ability to evaluate the residents' skills. METHODS: A total of 45 EM residents at two institutions were randomized into two groups. Each group was assigned to one of two formats involving an ectopic pregnancy scenario. One format incorporated the new hybrid model, in which residents had to manipulate an endovaginal US probe in a task trainer; the other used the standard high-fidelity simulation mannequin together with static photo images. After finishing the scenario, residents self-rated their overall learning experience and how well the scenario evaluated their ability to interpret endovaginal US images. Faculty members reviewed video recordings of the other institution's residents and rated their own ability to evaluate residents' skills in interpreting endovaginal US images and diagnosing and managing the case scenario. Visual analog scales (VAS) were used for the self-ratings. RESULTS: Compared to the residents assigned to the standard simulation scenario, residents assigned to the hybrid model reported an increase in their overall educational experience (Delta VAS = 10, 95% confidence interval [CI] = 4 to 18) and felt the hybrid model was a better measure of their ability to interpret endovaginal US images (Delta VAS = 17, 95% CI = 7 to 28). Faculty members found the hybrid model to be better than the standard simulation for evaluating residents' skills in interpreting endovaginal US images (Delta VAS = 13, 95% CI = 6 to 20) and diagnosing and managing the case (Delta VAS = 10, 95% CI = 2 to 18). Time to reach a diagnosis was similar in both groups (p = 0.053). CONCLUSIONS: Use of a hybrid simulation model combining a high-fidelity simulation with an endovaginal US task trainer improved residents' educational experience and improved faculty's ability to evaluate residents' endovaginal US and clinical skills. This novel hybrid tool should be considered for future education and evaluation of EM residents.


Assuntos
Medicina de Emergência/educação , Internato e Residência , Simulação de Paciente , Gravidez Ectópica/diagnóstico por imagem , Competência Clínica , Feminino , Humanos , Manequins , Obstetrícia/educação , Gravidez , Ensino/métodos , Fatores de Tempo , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA