1.
Physiol Meas ; 28(6): 639-49, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17664618

RESUMO

Oxygen and acid-base status during exercise is well established for the lungs, large arteries and veins. However, values for these parameters in exercising muscle are less frequently reported. In this study we examined the relationship between intramuscular PO(2), pH, PCO(2) and the comparable venous values during rhythmic isometric handgrip exercise at target levels of 15%, 30% and 45% of maximum voluntary contraction (MVC). A small fiber optic sensor was inserted into the flexor digitorum profundus (FDP) muscle for continuous measurement of intramuscular (IM) PO(2), pH and PCO(2). Venous blood samples were taken from the forearm every minute during each exercise bout. IM pH and PCO(2) were similar to their venous counterparts at baseline, but the difference between IM and venous values increased when exercise exceeded 30% MVC. During exercise at 15% MVC and greater, venous PO(2) declined from 40 to 21 Torr (approximately 5.3 to 2.8 kPa). IM PO(2) declined from 24 to 8 Torr with 15% MVC, and approached 0 Torr at 30% MVC and 45% MVC. IM pH declined rapidly when IM PO(2) reached 10 Torr and continued to decrease with increasing exertion, despite an IM PO(2) near 0 Torr.


Assuntos
Dióxido de Carbono/metabolismo , Exercício Físico/fisiologia , Força da Mão/fisiologia , Músculo Esquelético/fisiologia , Oxigênio/metabolismo , Veias/metabolismo , Adulto , Dióxido de Carbono/sangue , Feminino , Humanos , Concentração de Íons de Hidrogênio , Ácido Láctico/sangue , Masculino , Oxigênio/sangue , Pressão Parcial , Temperatura , Fatores de Tempo
2.
Opt Lett ; 30(17): 2269-71, 2005 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-16190440

RESUMO

We have demonstrated simultaneous correction for the optical interference of skin and fat in tissue spectra by using a two-distance fiber-optic probe. We obtained the correction by orthogonalizing the spectra collected at a long source-detector distance (SD) to the spectra collected at a short SD and mapped to the long SD space. The method was validated in tissuelike three-layer phantoms as well as preliminarily in human tissue. After the correction, a partial-least-squares model of the phantoms showed enhanced prediction performance.


Assuntos
Tecido Adiposo/química , Algoritmos , Tecnologia de Fibra Óptica/instrumentação , Músculo Esquelético/química , Pigmentação da Pele/fisiologia , Espectroscopia de Infravermelho com Transformada de Fourier/instrumentação , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Tecido Adiposo/fisiologia , Artefatos , Desenho de Equipamento , Análise de Falha de Equipamento , Tecnologia de Fibra Óptica/métodos , Humanos , Músculo Esquelético/fisiologia , Fibras Ópticas , Imagens de Fantasmas , Projetos Piloto , Transdutores