Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Nucl Med ; 20(6): 409-16, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16922469

RESUMO

OBJECTIVES: Pinhole SPECT which permits in vivo high resolution 3D imaging of physiological functions in small animals facilitates objective assessment of pharmaceutical development and regenerative therapy in pre-clinical trials. For handiness and mobility, the miniature size of the SPECT system is useful. We developed a small animal SPECT system based on a compact high-resolution gamma camera fitted to a pinhole collimator and an object-rotating unit. This study was aimed at evaluating the basic performance of the detection system and the feasibility of small animal SPECT imaging. METHODS: The gamma camera consists of a 22 x 22 pixellated scintillator array of 1.8 mm x 1.8 mm x 5 mm NaI(Tl crystals with 0.2-mm gap between the crystals coupled to a 2" flat panel position-sensitive photomultiplier tube (Hamamatsu H8500) with 64 channels. The active imaging region of the camera was 43.8 mm x 43.8 mm. Data acquisition is controlled by a personal computer (Microsoft Windows) through the camera controller. Projection data over 360 degrees for SPECT images are obtained by synchronizing with the rotating unit. The knife-edge pinhole collimators made of tungsten are attached on the camera and have 0.5-mm and 1.0-mm apertures. The basic performance of the detection system was evaluated with 99mTc and 201Tl solutions. Energy resolution, system spatial resolution and linearity of count rate were measured. Rat myocardial perfusion SPECT scans were sequentially performed following intravenous injection of 201TlCl. Projection data were reconstructed using a previously validated pinhole 3D-OSEM method. RESULTS: The energy resolution at 140 keV was 14.8% using a point source. The system spatial resolutions were 2.8-mm FWHM and 2.5-mm FWHM for 99mTc and 201Tl line sources, respectively, at 30-mm source distance (magnification factor of 1.3) using a 1.0-mm pinhole. The linearity between the activity and count rate was good up to 10 kcps. In a rat study, the left ventricular walls were clearly visible in all scans. CONCLUSIONS: We developed a compact SPECT system using compact gamma camera for small animals and evaluated basic physical performances. The present system may be of use for quantitation of biological functions such as myocardial blood flow in small animals.


Assuntos
Câmaras gama , Ventrículos do Coração/diagnóstico por imagem , Aumento da Imagem/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/veterinária , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/métodos , Masculino , Miniaturização , Imagens de Fantasmas , Ratos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador , Tomografia Computadorizada de Emissão de Fóton Único/métodos
2.
Ann Nucl Med ; 20(3): 245-51, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16715958

RESUMO

Recently, small animal imaging by pinhole SPECT has been widely investigated by several researchers. We developed a pinhole SPECT system specially designed for small animal imaging. The system consists of a rotation unit for a small animal and a SPECT camera attached with a pinhole collimator. In order to acquire complete data of the projections, the system has two orbits with angles of 90 degrees and 45 degrees with respect to the object. In this system, the position of the SPECT camera is kept fixed, and the animal is rotated in order to avoid misalignment of the center of rotation (COR). We implemented a three dimensional OSEM algorithm for the reconstruction of data acquired by the system from both the orbitals. A point source experiment revealed no significant COR misalignment using the proposed system. Experiments with a line phantom clearly indicated that our system succeeded in minimizing the misalignment of the COR. We performed a study with a rat and 99mTc-HMDP, an agent for bone scan, and demonstrated a dramatic improvement in the spatial resolution and uniformity achieved by our system in comparison with the conventional Feldkamp algorithm with one set of orbital data.


Assuntos
Aumento da Imagem/instrumentação , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia por Emissão de Pósitrons/veterinária , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/métodos , Imagens de Fantasmas , Ratos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Eur J Nucl Med Mol Imaging ; 31(8): 1166-72, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15029462

RESUMO

Pinhole single-photon emission computed tomography (SPECT) is able to provide information on the biodistribution of several radioligands in small laboratory animals, but has limitations associated with non-uniform spatial resolution or axial blurring. We have hypothesised that this blurring is due to incompleteness of the projection data acquired by a single circular pinhole orbit, and have evaluated a new strategy for accurate image reconstruction with better spatial resolution uniformity. A pinhole SPECT system using two circular orbits and a dedicated three-dimensional ordered subsets expectation maximisation (3D-OSEM) reconstruction method were developed. In this system, not the camera but the object rotates, and the two orbits are at 90 degrees and 45 degrees relative to the object's axis. This system satisfies Tuy's condition, and is thus able to provide complete data for 3D pinhole SPECT reconstruction within the whole field of view (FOV). To evaluate this system, a series of experiments was carried out using a multiple-disk phantom filled with 99mTc solution. The feasibility of the proposed method for small animal imaging was tested with a mouse bone study using 99mTc-hydroxymethylene diphosphonate. Feldkamp's filtered back-projection (FBP) method and the 3D-OSEM method were applied to these data sets, and the visual and statistical properties were examined. Axial blurring, which was still visible at the edge of the FOV even after applying the conventional 3D-OSEM instead of FBP for single-orbit data, was not visible after application of 3D-OSEM using two-orbit data. 3D-OSEM using two-orbit data dramatically reduced the resolution non-uniformity and statistical noise, and also demonstrated considerably better image quality in the mouse scan. This system may be of use in quantitative assessment of bio-physiological functions in small animals.


Assuntos
Algoritmos , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Imageamento Tridimensional/instrumentação , Camundongos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Ann Nucl Med ; 17(2): 99-106, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12790357

RESUMO

OBJECTIVES: Accurate mu maps are important for quantitative image reconstruction in SPECT. The Compton scatter energy window (CSW) technique has been proposed to define the outline of objects. In this technique, a lower energy window image is acquired in addition to the main photo-peak energy window. The image of the lower energy window is used to estimate the edge of the scanned object to produce a constant attenuation map. The aim of this study was to investigate the dependency of CSW on the spatial and energy distribution of radioisotope to predict the edges of objects. METHODS: Two particular cases of brain study were considered, namely uniform distribution and non-uniform distribution using Monte Carlo simulation and experiments with uniform cylindrical phantom and hotspot phantom. The phantoms were filled with water and a radioactive solution of 99mTc. For each phantom, 20%, 30%, 40% and 50% thresholds of the mean profile were applied to estimate Ewt, the energy window for minimum difference between the estimated and true edge of objects. RESULTS: The Ewt's were 100-120 keV with a 40% threshold and 92-114 keV with a 30% threshold for uniform and hotspot phantoms, respectively. CONCLUSIONS: Edge of the objects with CSW technique varies with energy window and thresholds. Careful setting of the energy window is required to use the CSW technique.


Assuntos
Algoritmos , Encéfalo/diagnóstico por imagem , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Modelos Biológicos , Reconhecimento Automatizado de Padrão , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Simulação por Computador , Transferência de Energia , Humanos , Imagens de Fantasmas , Fótons , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
5.
Phys Med Biol ; 48(8): 995-1008, 2003 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-12741497

RESUMO

In quantitative pinhole SPECT, photon penetration through the collimator edges (penetration), and photon scattering by the object (object scatter) and collimator (collimator scatter) have not been investigated rigorously. Monte Carlo simulation was used to evaluate these three physical processes for different tungsten knife-edge pinhole collimators using uniform, hotspot and donut phantoms filled with 201Tl, 99mTc, 123I and 131I solutions. For the hotspot phantom, the penetration levels with respect to total counts for a 1 mm pinhole aperture were 78%, 28% and 23% for 131I, 123I and 99mTc, respectively. For a 2 mm aperture, these values were 65% for 131I, 16% for 123I and 12% for 99mTc. For all pinholes, 201Tl penetration was less than 4%. The evaluated scatter (from object and collimator) with a hotspot phantom for the 1 mm pinhole was 24%, 16%, 18% and 13% for 201Tl, 99mTc, 123I and 131I, respectively. Summation of the object and collimator scatter for the uniform phantom was approximately 20% higher than that for the hotspot phantom. Significant counts due to penetration and object and collimator scatter in the reconstructed image were observed inside the core of the donut phantom. The collimator scatter can be neglected for all isotopes used in this study except for 131I. Object scatter correction for all radionuclides used in this study is necessary and correction for the penetration contribution is necessary for all radionuclides but 201Tl.


Assuntos
Análise de Falha de Equipamento , Método de Monte Carlo , Radioisótopos/análise , Radiometria/métodos , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Absorção , Simulação por Computador , Testes de Sensibilidade Microbiana , Imagens de Fantasmas , Controle de Qualidade , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...