Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Intensive Care Med ; 35(10): 1123-1128, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30572756

RESUMO

PURPOSE: Passive leg raise (PLR), in combination with technologies capable of capturing stroke volume changes, has been widely adopted in the management of shock. However, dedicated evaluation of safety, feasibility, and receptiveness of patients and nursing staff to PLR maneuver is missing. METHODS: A noninterventional, prospective trial recruited adult patients with onset of undifferentiated shock within 24 hours with persistent vasopressor requirements despite fluid resuscitation. A standardized PLR maneuver was used to compare two noninvasive hemodynamic monitoring systems, each without significant impact on the performance of the maneuver. Safety and efficacy of the PLR were evaluated via subjective and objective measures. Objective measures of patient comfort and tolerance were evaluated through changes in vital signs, sedation, and analgesia requirements. Nurses and awake patients completed surveys on their experience. RESULTS: Seventy-nine patients were enrolled. Testing was aborted in 2 cases for medical reasons (one patient developed rapid atrial fibrillation, second had profound desaturation). Of all, 5.4% of patients required additional vasopressor support after completion of the PLR maneuver due to persistent hypotension and 4.1% of patients required additional sedation. Among awake patients (N = 35), 6% reported pain and 29% reported discomfort. A total of 11% of nurses reported minor technical difficulties with the maneuver. CONCLUSION: Passive leg raise maneuver leads to a few serious but reversible complications in a selected population of hemodynamically unstable patients. Although it provides relevant diagnostic information, it may impact patient care. Treating physician should be aware of infrequent but possible complications and appreciate the impact of the maneuver on patients' comfort and nursing workload.


Assuntos
Cuidados Críticos/métodos , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Posicionamento do Paciente/métodos , Choque/terapia , Idoso , Analgesia/estatística & dados numéricos , Estudos de Viabilidade , Feminino , Hemodinâmica , Humanos , Hipnóticos e Sedativos/uso terapêutico , Unidades de Terapia Intensiva , Perna (Membro) , Masculino , Pessoa de Meia-Idade , Postura , Estudos Prospectivos , Choque/fisiopatologia , Resultado do Tratamento
2.
Crit Care Med ; 46(11): e1040-e1046, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30134304

RESUMO

OBJECTIVES: Adequate assessment of fluid responsiveness in shock necessitates correct interpretation of hemodynamic changes induced by preload challenge. This study evaluates the accuracy of point-of-care Doppler ultrasound assessment of the change in carotid corrected flow time induced by a passive leg raise maneuver as a predictor of fluid responsiveness. Noninvasive cardiac output monitoring (NICOM, Cheetah Medical, Newton Center, MA) system based on a bioreactance method was used. DESIGN: Prospective, noninterventional study. SETTING: ICU at a large academic center. PATIENTS: Patients with new, undifferentiated shock, and vasopressor requirements despite fluid resuscitation were included. Patients with significant cardiac disease and conditions that precluded adequate passive leg raising were excluded. INTERVENTIONS: Carotid corrected flow time was measured via ultrasound before and after a passive leg raise maneuver. Predicted fluid responsiveness was defined as greater than 10% increase in stroke volume on noninvasive cardiac output monitoring following passive leg raise. Images and measurements were reanalyzed by a second, blinded physician. The accuracy of change in carotid corrected flow time to predict fluid responsiveness was evaluated using receiver operating characteristic analysis. MEASUREMENTS AND MAIN RESULTS: Seventy-seven subjects were enrolled with 54 (70.1%) classified as fluid responders by noninvasive cardiac output monitoring. The average change in carotid corrected flow time after passive leg raise for fluid responders was 14.1 ± 18.7 ms versus -4.0 ± 8 ms for nonresponders (p < 0.001). Receiver operating characteristic analysis demonstrated that change in carotid corrected flow time is an accurate predictor of fluid responsiveness status (area under the curve, 0.88; 95% CI, 0.80-0.96) and a 7 ms increase in carotid corrected flow time post passive leg raise was shown to have a 97% positive predictive value and 82% accuracy in detecting fluid responsiveness using noninvasive cardiac output monitoring as a reference standard. Mechanical ventilation, respiratory rate, and high positive end-expiratory pressure had no significant impact on test performance. Post hoc blinded evaluation of bedside acquired measurements demonstrated agreement between evaluators. CONCLUSIONS: Change in carotid corrected flow time can predict fluid responsiveness status after a passive leg raise maneuver. Using point-of-care ultrasound to assess change in carotid corrected flow time is an acceptable and reproducible method for noninvasive identification of fluid responsiveness in critically ill patients with undifferentiated shock.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Hidratação/métodos , Hemodinâmica/fisiologia , Fluxo Sanguíneo Regional/fisiologia , Choque Séptico/diagnóstico por imagem , Idoso , Estado Terminal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Estudos Prospectivos , Choque Séptico/fisiopatologia , Ultrassonografia Doppler/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...