2.
Acta Ophthalmol ; 97(1): e57-e63, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30284403

RESUMO

PURPOSE: Develop an algorithm to predict the success of laser peripheral iridotomy (LPI) in primary angle closure suspect (PACS), using pretreatment anterior segment optical coherence tomography (ASOCT) scans. METHODS: A total of 69 eyes with PACS underwent LPI and time-domain ASOCT scans (temporal and nasal cuts) were performed before and after LPI. After LPI, success is defined as one or more angles changed from closed to open. All the pretreatment ASOCT scans were analysed using the Anterior Segment Analysis Program to derive anterior chamber angle (ACA) measurements. The measurements for each angle were ordered along with angle-independent measurements totalling to 42 measurements which serve as features for the prediction algorithm. Two masked glaucoma fellowship-trained ophthalmologists graded the pre-LPI ASOCT scans to determine whether LPI was likely to successful. RESULTS: There were 42 (60.9%) eyes that fulfilled the criteria for success after LPI. Iris concavity, angle recess area (750 µm) and iris concavity ratio showed the highest predictive score and were selected using correlation-based subset selection method. These features were classified into two ('successful' and 'unsuccessful') categories using a Bayes classifier. The algorithm predicted the success of LPI with 79.28% cross validation accuracy, which was superior to the predictive accuracy of the ophthalmologists (kappa 0.497 and 0.636 respectively). CONCLUSION: Using pretreatment ASOCT scans, our algorithm was superior to ophthalmologists in predicting the success of LPI for PACS eyes. This novel algorithm could aid decision making in offering LPI as a prophylaxis for PACS.


Assuntos
Algoritmos , Segmento Anterior do Olho/diagnóstico por imagem , Glaucoma de Ângulo Fechado/cirurgia , Iridectomia/métodos , Terapia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Tomografia de Coerência Óptica/métodos , Feminino , Seguimentos , Glaucoma de Ângulo Fechado/diagnóstico , Glaucoma de Ângulo Fechado/fisiopatologia , Gonioscopia , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
3.
J Med Syst ; 42(6): 107, 2018 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-29704138

RESUMO

Develop an algorithm to predict the success of laser peripheral iridotomy (LPI) in primary angle closure suspect (PACS), using pre-treatment anterior segment optical coherence tomography (ASOCT) scans. A total of 116 eyes with PACS underwent LPI and time-domain ASOCT scans (temporal and nasal cuts) were performed before and 1 month after LPI. All the post-treatment scans were classified to one of the following categories: (a) both angles open, (b) one of two angles open and (c) both angles closed. After LPI, success is defined as one or more angles changed from close to open. In this proposed method, the pre and post-LPI ASOCT scans were registered at the corresponding angles based on similarities between the respective local descriptor features and random sample consensus technique was used to identify the largest consensus set of correspondences between the pre and post-LPI ASOCT scans. Subsequently, features such as correlation co-efficient (CC) and structural similarity index (SSIM) were extracted and correlated with the success of LPI. We included 116 eyes and 91 (78.44%) eyes fulfilled the criteria for success after LPI. Using the CC and SSIM index scores from this training set of ASOCT images, our algorithm showed that the success of LPI in eyes with narrow angles can be predicted with 89.7% accuracy, specificity of 95.2% and sensitivity of 36.4% based on pre-LPI ASOCT scans only. Using pre-LPI ASOCT scans, our proposed algorithm showed good accuracy in predicting the success of LPI for PACS eyes. This fully-automated algorithm could aid decision making in offering LPI as a prophylactic treatment for PACS.


Assuntos
Algoritmos , Glaucoma de Ângulo Fechado/cirurgia , Iridectomia/métodos , Terapia a Laser/métodos , Tomografia de Coerência Óptica/métodos , Idoso , Câmara Anterior/patologia , Feminino , Humanos , Pressão Intraocular , Lasers de Estado Sólido , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade
4.
Clin Ophthalmol ; 10: 757-64, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27175058

RESUMO

PURPOSE: To investigate the efficacy and safety of a punctum plug-based sustained drug release system for a prostaglandin analog, travoprost (OTX-TP), for intraocular pressure (IOP) reduction in an Asian population. METHODS: This is an initial feasibility, prospective, single-arm study involving 26 eyes and a bioresorbable punctum plug containing OTX-TP. An OTX-TP was placed in the vertical portion of the superior or inferior canaliculus of patients with primary open-angle glaucoma or ocular hypertension. The main outcome measure was the IOP-lowering efficacy of OTX-TP at 3 (8 am) and 10, 20, and 30 days (8 am, 10 am, and 4 pm), compared to baseline. RESULTS: A total of 26 OTX-TP were inserted for 17 subjects. The mean (standard deviation) age was 57.2 (13.8) years. At 10 days, all plugs were still present, and the IOP reduction from baseline was 6.2 (23%), 5.4 (21%), and 7.5 mmHg (28%) at 8 am, 10 am, and 4 pm, respectively. At 10 days, the mean IOP (standard error of mean) was 21.2 (1.2), 20.4 (0.8), and 19.7 (1.0) at 8 am, 10 am, and 4 pm, respectively, showing no discernible IOP trend during the course of the day. At 30 days, plug retention had declined to 42%, and the overall IOP reduction had decreased to 16%. CONCLUSION: The sustained-release OTX-TP is able to reduce IOP by 24% (day 10) and 15.6% (day 30), respectively. It is a potentially well-tolerable ocular hypotensive for glaucoma patients with a history of poor compliance.

5.
Br J Ophthalmol ; 100(4): 542-8, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26294102

RESUMO

PURPOSE: To compare the effect of argon laser peripheral iridoplasty (ALPI) and conventional medical therapy in the immediate treatment of acute primary angle closure (APAC) using anterior segment optical coherence tomography (ASOCT). METHODS: In this single tertiary centre, prospective comparative study, we randomised 30 consecutive patients with unilateral APAC into two groups: ALPI and medical treatment (n=15 each). Immediately before and 1 h after either intervention, ASOCT imaging was performed. Custom software was used to measure pupil diameter, anterior chamber depth, iris curvature (I-Curv), iris area (I-Area), and the angle opening distance (AOD750), trabecular iris space area (TISA750) and the iris thickness at 750 µm from the scleral spur. The main outcome measure was the change in anterior segment biometrical parameters. RESULTS: The mean age of the patients was 62.8±7.7 years; 13 (43.3%) were male. APAC eyes treated with ALPI had a larger increase in AOD750 (p=0.002) and TISA750 (p=0.006); a smaller increase in I-Area (p=0.004) and a decrease in I-Curv (p=0.001) after treatment compared with those eyes which received medical therapy. An optimal model consisting of age, gender, pretreatment and post-treatment pupil diameter, treatment modality and pretreatment I-Curv explained 53.2% of the variance in AOD750 change after treatment, with the treatment modality accounting for 35.0% and I-Curv accounting for 12.4% of the variability. CONCLUSIONS: We observed a greater increase in angle width after ALPI compared with after medical treatment in eyes with APAC. Treatment modality and pretreatment I-Curv were the most significant predictors of angle width change after treatment.


Assuntos
Segmento Anterior do Olho/patologia , Anti-Hipertensivos/uso terapêutico , Coagulação com Plasma de Argônio , Glaucoma de Ângulo Fechado/terapia , Iridectomia , Iris/cirurgia , Doença Aguda , Idoso , Tartarato de Brimonidina/uso terapêutico , Feminino , Glaucoma de Ângulo Fechado/tratamento farmacológico , Glaucoma de Ângulo Fechado/cirurgia , Gonioscopia , Humanos , Pressão Intraocular/efeitos dos fármacos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Soluções Oftálmicas , Pilocarpina/uso terapêutico , Estudos Prospectivos , Centros de Atenção Terciária , Timolol/uso terapêutico , Tomografia de Coerência Óptica , Tonometria Ocular
6.
Clin Exp Ophthalmol ; 43(1): 40-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-24811050

RESUMO

BACKGROUND: The aim of this study was to compare the efficacy and safety of micropulse and continuous wave diode transscleral cyclophotocoagulation in refractory glaucoma. DESIGN: Randomized, comparative, exploratory study in a tertiary hospital setting. PARTICIPANTS: Patients with refractory, end-stage glaucoma. METHODS: Forty-eight patients were randomized to either treatment. The intraocular pressure, visual acuity, number of medicines and repeat treatment were monitored for 18 months. Complications that include visual acuity decline, prolonged anterior chamber inflammation, phthisis bulbi, scleral thinning and ocular pain were noted. MAIN OUTCOME MEASURE: Intraocular pressure between 6 and 21 mmHg and at least a 30% reduction with or without anti-glaucoma medications after 18 months. RESULTS: A successful primary outcome was achieved in 75% of patients who underwent micropulse cyclophotocoagulation and 29% of patients who received continuous wave cyclophotocoagulation after 12 months (P < 0.01). At 18 months, successful outcome was 52% and 30% (P = 0.13), respectively. The mean intraocular pressure was reduced by 45% in both groups (P = 0.70) from a baseline of 36.5 mmHg and 35.0 mmHg (P = 0.50) after 17.5 ± 1.6 months (range 16-19) follow up. No significant difference in retreatment rates or number of intraocular pressure lowering medications was noted. The ocular complication rate was higher in continuous wave treated eyes (P = 0.01). CONCLUSION: Diode transscleral cyclophotocoagulation in both micropulse and continuous modes was effective in lowering intraocular pressure. The micropulse mode provided a more consistent and predictable effect in lowering intraocular pressure with minimal ocular complications.


Assuntos
Corpo Ciliar/cirurgia , Glaucoma/cirurgia , Fotocoagulação a Laser/métodos , Lasers Semicondutores/uso terapêutico , Idoso , Corpo Ciliar/fisiopatologia , Feminino , Glaucoma/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Esclera , Centros de Atenção Terciária , Tonometria Ocular , Acuidade Visual/fisiologia
7.
Ophthalmology ; 121(1): 119-125, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24183421

RESUMO

OBJECTIVE: To describe anterior segment optical coherence tomography (ASOCT) parameters during acute primary angle closure (APAC) before therapeutic interventions and comparative analyses of biometric parameters of APAC eyes with fellow eyes. DESIGN: Prospective, comparative case series. PARTICIPANTS: Thirty-one consecutive patients with APAC. METHODS: All patients underwent ASOCT imaging of both eyes during the attack, before therapeutic interventions were administered. Custom software was used to measure anterior chamber depth (ACD), anterior chamber area (ACA), anterior chamber volume (ACV), iris curvature (I-Curv), iris area (I-Area), lens vault (LV), and angle opening distance (AOD750), trabecular iris space area (TISA750), and iris thickness (IT750) at 750 µm from the scleral spur. Multivariate logistic regression modeling using forward selection was used to determine the most important biometric variables associated with APAC compared with the fellow eye during the attack. MAIN OUTCOME MEASURES: Anterior segment biometric parameters associated with APAC. RESULTS: The mean age of the patients was 60.9±7.5 years, and 11 patients (35.5%) were male. The mean intraocular pressure was 3.8±9.2 mmHg in the APAC eye and 4.2±4.3 mmHg in the fellow eye before treatment (P <0.001). After adjustment for pupil diameter, APAC eyes had smaller ACD, ACA, ACV, I-Curv (all P <0.001), AOD750 (P = 0.037), TISA750 (P = 0.043), I-Area (P = 0.027), and IT750 (P = 0.002) and larger LV (P = 0.041) than fellow eyes. An optimal model consisting of 3 variables (pupil diameter, ACD, and I-Curv) explained 36.7% of the variance in APAC occurrence, with ACD accounting for 18.1% and I-Curv accounting for 14.1% of this variance. CONCLUSIONS: Shallower ACD and smaller I-Curv were the 2 main anterior segment biometric parameters associated with APAC during the attack. These findings present new insights into the anterior segment biometric parameters of APAC and fellow eyes before therapeutic interventions. Anatomic changes in the anterior segment explained only about one third of the variance in APAC occurrence, and the role of nonanatomic factors require further investigation.


Assuntos
Segmento Anterior do Olho/patologia , Glaucoma de Ângulo Fechado/diagnóstico , Tomografia de Coerência Óptica , Doença Aguda , Biometria , Feminino , Gonioscopia , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tonometria Ocular
8.
Indian J Ophthalmol ; 59 Suppl: S82-7, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21150039

RESUMO

Primary angle closure glaucoma (PACG) is equally prevalent in Indian in Asian population as the primary open angle glaucoma. Eighty-six percent of people with PACG are in Asia, with approximately 48.0% in China, 23.9% in India and 14.1% in southeast Asia. To understand PACG, it is mandatory to understand its classification and type of presentation with the underlying pathophysiology. The treatment options are medical, laser and/or surgical. The present article provides an overview of PACG.


Assuntos
Anti-Hipertensivos/uso terapêutico , Glaucoma de Ângulo Fechado/tratamento farmacológico , Glaucoma de Ângulo Fechado/cirurgia , Iris/cirurgia , Procedimentos Cirúrgicos Oftalmológicos , Doença Aguda , Ásia/epidemiologia , China/epidemiologia , Doença Crônica , Glaucoma de Ângulo Fechado/epidemiologia , Humanos , Terapia a Laser , Prevalência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...