Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Appl Physiol (1985) ; 116(4): 451-61, 2014 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-24356515

RESUMO

The Zone model of pulmonary perfusion predicts that exercise reduces perfusion heterogeneity because increased vascular pressure redistributes flow to gravitationally nondependent lung, and causes dilation and recruitment of blood vessels. However, during exercise in animals, perfusion heterogeneity as measured by the relative dispersion (RD, SD/mean) is not significantly decreased. We evaluated the effect of exercise on pulmonary perfusion in six healthy supine humans using magnetic resonance imaging (MRI). Data were acquired at rest, while exercising (∼27% of maximal oxygen consumption) using a MRI-compatible ergometer, and in recovery. Images were acquired in most of the right lung in the sagittal plane at functional residual capacity, using a 1.5-T MR scanner equipped with a torso coil. Perfusion was measured using arterial spin labeling (ASL-FAIRER) and regional proton density using a fast multiecho gradient-echo sequence. Perfusion images were corrected for coil-based signal heterogeneity, large conduit vessels removed and quantified (in ml·min(-1)·ml(-1)) (perfusion), and also normalized for density and quantified (in ml·min(-1)·g(-1)) (density-normalized perfusion, DNP) accounting for tissue redistribution. DNP increased during exercise (11.1 ± 3.5 rest, 18.8 ± 2.3 exercise, 13.2 ± 2.2 recovery, ml·min(-1)·g(-1), P < 0.0001), and the increase was largest in nondependent lung (110 ± 61% increase in nondependent, 63 ± 35% in mid, 70 ± 33% in dependent, P < 0.005). The RD of perfusion decreased with exercise (0.93 ± 0.21 rest, 0.73 ± 0.13 exercise, 0.94 ± 0.18 recovery, P < 0.005). The RD of DNP showed a similar trend (0.82 ± 0.14 rest, 0.75 ± 0.09 exercise, 0.81 ± 0.10 recovery, P = 0.13). In conclusion, in contrast to animal studies, in supine humans, mild exercise decreased perfusion heterogeneity, consistent with Zone model predictions.


Assuntos
Exercício Físico , Pulmão/irrigação sanguínea , Imageamento por Ressonância Magnética , Imagem de Perfusão/métodos , Circulação Pulmonar , Decúbito Dorsal , Adulto , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Medidas de Volume Pulmonar , Masculino , Consumo de Oxigênio , Valor Preditivo dos Testes , Fluxo Sanguíneo Regional , Fatores de Tempo
2.
J Appl Physiol (1985) ; 107(5): 1559-68, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19745192

RESUMO

Exercise presents a considerable stress to the pulmonary system and ventilation-perfusion (Va/Q) heterogeneity increases with exercise, affecting the efficiency of gas exchange. In particular, prolonged heavy exercise and maximal exercise are known to increase Va/Q heterogeneity and these changes persist into recovery. We hypothesized that the spatial heterogeneity of pulmonary perfusion would be similarly elevated after prolonged exercise. To test this, athletic subjects (n = 6, Vo(2max) = 61 ml. kg(-1).min(-1)) with exercising Va/Q heterogeneity previously characterized by the multiple inert gas elimination technique (MIGET), performed 45 min of cycle exercise at approximately 70% Vo(2max). MRI arterial spin labeling measures of pulmonary perfusion were acquired pre- and postexercise (at 20, 40, 60 min post) to quantify the spatial distribution in isogravitational (coronal) and gravitationally dependent (sagittal) planes. Regional proton density measurements allowed perfusion to be normalized for density and quantified in milliliters per minute per gram. Mean lung density did not change significantly in either plane after exercise (P = 0.19). Density-normalized perfusion increased in the sagittal plane postexercise (P =or <0.01) but heterogeneity did not (all P >or= 0.18), likely because of perfusion redistribution and vascular recruitment. Density-normalized perfusion was unchanged in the coronal plane postexercise (P = 0.66), however, perfusion heterogeneity was significantly increased as measured by the relative dispersion [RD, pre 0.62(0.07), post 0.82(0.21), P < 0.0001] and geometric standard deviation [GSD, pre 1.74(0.14), post 2.30(0.56), P < 0.005]. These changes in heterogeneity were related to the exercise-induced changes of the log standard deviation of the ventilation distribution, an MIGET index of Va/Q heterogeneity (RD R(2) = 0.68, P < 0.05, GSD, R(2) = 0.55, P = 0.09). These data are consistent with but not proof of interstitial pulmonary edema as the mechanism underlying exercise-induced increases in both spatial perfusion heterogeneity and Va/Q heterogeneity.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Consumo de Oxigênio/fisiologia , Resistência Física/fisiologia , Esforço Físico/fisiologia , Circulação Pulmonar/fisiologia , Humanos , Masculino , Adulto Jovem
3.
J Appl Physiol (1985) ; 106(4): 1057-64, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19057006

RESUMO

We hypothesized that some of the heterogeneity of pulmonary blood flow present in the normal human lung in normoxia is due to hypoxic pulmonary vasoconstriction (HPV). If so, mild hyperoxia would decrease the heterogeneity of pulmonary perfusion, whereas it would be increased by mild hypoxia. To test this, six healthy nonsmoking subjects underwent magnetic resonance imaging (MRI) during 20 min of breathing different oxygen concentrations through a face mask [normoxia, inspired O(2) fraction (Fi(O(2))) = 0.21; hypoxia, Fi(O(2)) = 0.125; hyperoxia, Fi(O(2)) = 0.30] in balanced order. Data were acquired on a 1.5-T MRI scanner during a breath hold at functional residual capacity from both coronal and sagittal slices in the right lung. Arterial spin labeling was used to quantify the spatial distribution of pulmonary blood flow in milliliters per minute per cubic centimeter and fast low-angle shot to quantify the regional proton density, allowing perfusion to be expressed as density-normalized perfusion in milliliters per minute per gram. Neither mean proton density [hypoxia, 0.46(0.18) g water/cm(3); normoxia, 0.47(0.18) g water/cm(3); hyperoxia, 0.48(0.17) g water/cm(3); P = 0.28] nor mean density-normalized perfusion [hypoxia, 4.89(2.13) ml x min(-1) x g(-1); normoxia, 4.94(1.88) ml x min(-1) x g(-1); hyperoxia, 5.32(1.83) ml x min(-1) x g(-1); P = 0.72] were significantly different between conditions in either imaging plane. Similarly, perfusion heterogeneity as measured by relative dispersion [hypoxia, 0.74(0.16); normoxia, 0.74(0.10); hyperoxia, 0.76(0.18); P = 0.97], fractal dimension [hypoxia, 1.21(0.04); normoxia, 1.19(0.03); hyperoxia, 1.20(0.04); P = 0.07], log normal shape parameter [hypoxia, 0.62(0.11); normoxia, 0.72(0.11); hyperoxia, 0.70(0.13); P = 0.07], and geometric standard deviation [hypoxia, 1.88(0.20); normoxia, 2.07(0.24); hyperoxia, 2.02(0.28); P = 0.11] was also not different. We conclude that HPV does not affect pulmonary perfusion heterogeneity in normoxia in the normal supine human lung.


Assuntos
Hipóxia/fisiopatologia , Circulação Pulmonar/fisiologia , Decúbito Dorsal/fisiologia , Vasoconstrição/fisiologia , Adulto , Análise de Variância , Débito Cardíaco/fisiologia , Feminino , Volume Expiratório Forçado/fisiologia , Frequência Cardíaca/fisiologia , Humanos , Pulmão/fisiologia , Imageamento por Ressonância Magnética , Masculino , Consumo de Oxigênio/fisiologia , Perfusão , Testes de Função Respiratória , Resistência Vascular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...