1.
Rev. colomb. cardiol ; 29(supl.4): 38-41, dic. 2022. graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1423810

RESUMO

Abstract We present the first case in Colombia of tricuspid endovascular valve in valve for failed bioprosthesis in a 40 years old patient with very high operative risk with great results, proposing kissing balloon annulus cracking technique as a practical solution for the colombian specialists.


Resumen Se presenta el primer caso en Colombia de un reemplazo percutáneo tipo válvula en válvula por falla de bioprótesis tricúspide en un paciente de 40 años con un muy alto riesgo quirúrgico, con excelentes resultados, proponiendo la técnica kissing balloon de fractura anular como una solución práctica para los especialistas colombianos.

2.
Rev. colomb. cardiol ; 29(5): 593-596, jul.-set. 2022. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1423786

RESUMO

Abstract We present the first case in Colombia of tricuspid endovascular valve in valve for failed bioprosthesis in a 40-year-old patient with very high operative risk with great results, proposing kissing balloon annulus cracking technique as a practical solution for the Colombian specialists.


Resumen Presentamos el primer caso en Colombia de valve in valve tricúspideo para una bioprótesis deteriorada en una paciente de 40 años con muy alto riesgo quirúrgico con muy buenos resultados, y se propone la técnica de kissing balloon para ruptura anular como una solución practica para los especialistas en Colombia.

4.
Int J Cardiol ; 321: 48-53, 2020 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-32810542

RESUMO

BACKGROUND: RENASCENT is a prospective, multi-center first-in-human clinical study to evaluate the clinical performance of the novel sirolimus-eluting 150-µm strut thickness FORTITUDE® BRS for percutaneous coronary intervention of single de novo coronary lesions. METHODS: FORTITUDE® BRS was tested in a prospective study in Italy and Colombia. Study objectives were in-scaffold angiographic late lumen loss (LLL) measured by quantitative coronary angiography and target vessel failure (TVF) defined as the composite rate of cardiac death, target vessel myocardial infarction or ischemia driven target lesion revascularization (TLR) at 9- and 24-months with clinical results up to 36-months. RESULTS: A total of 63 patients were enrolled. All patients underwent lesion pre-dilatation and 22 patients (34.9%) underwent post-dilatation. Clinical device and procedural success was 98.4% (62/63 patients) and 96.8% (61/63 patients) respectively. At 9-months, TVF occurred in 3/61 (4.9%) of the patients including 2 peri-procedural MI and one ischemia-driven TLR. Between 9- to 24-months, ischemia-driven TLR occurred in 3 additional patients (4.9%) including 1 patient who presented with very late ST after stopping all medications. There were no further TVF between 24- and 36-months. CONCLUSIONS: In this multi-center prospective study, the FORTITUDE® BRS was shown to be safe and effective in the treatment of single coronary lesions with low levels of TVF and LLL at 9- and 24-months. It was shown to be clinically safe upto 36-months follow-up.


Assuntos
Fármacos Cardiovasculares , Doença da Artéria Coronariana , Reestenose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Implantes Absorvíveis , Fármacos Cardiovasculares/uso terapêutico , Colômbia , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/tratamento farmacológico , Doença da Artéria Coronariana/cirurgia , Reestenose Coronária/tratamento farmacológico , Humanos , Itália , Peso Molecular , Estudos Prospectivos , Desenho de Prótese , Sirolimo , Tomografia de Coerência Óptica , Resultado do Tratamento
5.
Open Heart ; 4(1): e000521, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28674616

RESUMO

OBJECTIVE: To evaluate the biological effect of microengineered stent grooves (MSG) on early strut healing in humans by performing optical coherence tomography (OCT) analysis 3 weeks following the implantation. BACKGROUND: In the experimental setting, MSG accelerate endothelial cell migration and reduce neointimal proliferation compared with bare metal stent (BMS). METHODS: A total of 37 patients undergoing percutaneous coronary intervention with de novo coronary lesions were randomly assigned to either MSG (n=19) or an identical BMS controls (n=18). All patients underwent OCT imaging at 3 weeks. A total of 7959 struts were included in the final analysis. RESULTS: At 3 weeks following stent implantation, almost all struts analysed (~97%) had evidence of tissue coverage. The percentage of partially covered struts was comparable between both groups. However, the percentage of fully embedded struts was higher in the BMS group (81.22%, 49.75-95.52) compared with the MSG group (74.21%, 58.85-86.38). The stent-level analysis demonstrated reduction in neointimal formation (neointimal hyperplasia area and volume reduction of ~14% and ~19%, respectively) in the MSG versus the BMS group. In the strut-level analysis, an even greater reduction (~22% in neointimal thickness) was seen in the MSG group. Layered neointimal was present in ~6% of the OCT frames in the BMS group while it was not present in the MSG group. CONCLUSIONS: MSG induced a more homogeneous and predictable pattern of surface healing in the early stages following stent implantation. The biological effect of MSG on stent healing has the potential to improve the safety profile of current generation drug-eluting stents. CLASSIFICATIONS: BMS, OCT, clinical trials.

6.
Coron Artery Dis ; 28(2): 126-134, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27879518

RESUMO

AIMS: Bioresorbable polymer drug-eluting stent technologies have been considered to have the potential to enhance vascular healing by reducing polymer exposure to the vessel wall, potentially allowing the earlier discontinuation of dual antiplatelet therapy. At present, the early vascular healing response to this type of technologies is still unclear. PATIENTS AND METHODS: The TIMELESS study is a multicenter, prospective, single-arm study that enrolled real-world patients undergoing percutaneous coronary intervention. All patients underwent Synergy stent implantation, which consists of a platinum-chromium platform coated with an ultra-thin abluminal bioabsorbable poly-D,L-lactide-co-glycolide polymer-eluting everolimus. RESULTS: A total of 37 patients were included in the study. The majority of the patients underwent percutaneous coronary intervention because of acute coronary syndromes. At 3 months, angiographic follow-up showed a percentage diameter of stenosis of 8.1±7.5% and an angiographic late loss of 0.03±0.24 mm. In all analyzed struts, less than 1% of struts were definitely uncovered or covered with fibrin, 12.5% (5.0-18.5%) showed evidence of partial coverage, and the remaining (∼85%) were fully covered. No stent thrombosis was observed up to 12 months of clinical follow-up. CONCLUSION: In a real-world population, the implantation of a bioresorbable polymer drug-eluting stent resulted in almost complete strut coverage throughout the entire stent length at 3 months. The clinical implications for antiplatelet therapy and outcomes should be investigated further.


Assuntos
Implantes Absorvíveis , Síndrome Coronariana Aguda/terapia , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Vasos Coronários/efeitos dos fármacos , Stents Farmacológicos , Everolimo/administração & dosagem , Ácido Láctico/química , Intervenção Coronária Percutânea/instrumentação , Ácido Poliglicólico/química , Tomografia de Coerência Óptica , Cicatrização/efeitos dos fármacos , Síndrome Coronariana Aguda/diagnóstico por imagem , Idoso , Fármacos Cardiovasculares/efeitos adversos , Cromo , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Quimioterapia Combinada , Everolimo/efeitos adversos , Feminino , Humanos , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/administração & dosagem , Platina , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento
7.
Tex Heart Inst J ; 39(3): 351-8, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22719143

RESUMO

At our institutions, increasing numbers of aortic stenosis patients were not candidates for surgical aortic valve replacement. Accordingly, we initiated the Cali Colombian Transcatheter Aortic Valve Implantation (TAVI) program. From March 2008 through January 2011, 53 consecutive patients (mean age, 79 ± 6 yr; men, 58%) underwent TAVI with the Medtronic CoreValve System, and data were prospectively collected. Our study's endpoints conformed with Valve Academic Research Consortium recommendations. We report our clinical results.Predicted mortality rates were 25% (interquartile range, 17%-34%) according to logistic EuroSCORE and 6% (interquartile range, 3%-8%) according to the Society of Thoracic Surgeons score. The 30-day mortality rate was 9% (3 intraprocedural deaths, 5 total). The combined 30-day safety endpoint was 30% (major vascular sequelae, 23%; life-threatening bleeding, 12%; myocardial infarction, 4%; major stroke, 4%; and acute kidney injury [stage 3], 2%). Eight patients (15%) required post-implantation balloon dilation and 2 (4%) required valve-in-valve implantation, for a technical device success rate of 77%. Mean peak transvalvular gradient decreased from 74 ± 29 to 17 ± 8 mmHg and mean transvalvular gradient from 40 ± 17 to 8 ± 4 mmHg (both P=0.001). Moderate or severe aortic regurgitation decreased from 32% to 18% (P=0.12) and mitral regurgitation from 32% to 13% (P=0.002). The 1-year survival rate was 81%.We found that TAVI with the CoreValve prosthesis was safe and feasible, with sustained long-term results, for treating aortic stenosis in patients at excessive surgical risk; nonetheless, serious adverse events occurred in 30% of the patients.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Colômbia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Mortalidade Hospitalar , Humanos , Estimativa de Kaplan-Meier , Masculino , Estudos Prospectivos , Desenho de Prótese , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
Acta méd. colomb ; 31(1): 40-46, ene.-mar. 2006. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-436718

RESUMO

La prolongación anormal del intervalo QT tiene relevancia por su asociación con inestabilidad eléctrica ventricular, pudiéndose presentar arritmias ventriculares polimórficas en "puntas torcidas". Los síntomas acompañantes de estas arritmias son el síncope, convulsiones o la muerte súbita. Se puede clasificar en síndrome de QT prolongado congénito, el cual se hereda o lo adquiere el individuo de manera esporádica y el síndrome adquirido que se puede presentar asociado a fármacos u otras situaciones clínicas. Presentamos el caso de una mujer de 41 años de edad que desarrolló cambios típicos de síndrome de QT prolongado por isquemia miocárdica y hacemos una breve revisión.