Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Cardiol Young ; : 1-6, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38724470

RESUMO

OBJECTIVE: Individuals with single ventricle physiology who are palliated with superior cavopulmonary anastomosis (Glenn surgery) may develop pulmonary arteriovenous malformations. The traditional tools for pulmonary arteriovenous malformation diagnosis are often of limited diagnostic utility in this patient population. We sought to measure the pulmonary capillary transit time to determine its value as a tool to identify pulmonary arteriovenous malformations in patients with single ventricle physiology. METHODS: We defined the angiographic pulmonary capillary transit time as the number of cardiac cycles required for transit of contrast from the distal pulmonary arteries to the pulmonary veins. Patients were retrospectively recruited from a single quaternary North American paediatric centre, and angiographic and clinical data were reviewed. Pulmonary capillary transit time was calculated in 20 control patients and compared to 20 single ventricle patients at the pre-Glenn, Glenn, and Fontan surgical stages (which were compared with a linear-mixed model). Correlation (Pearson) between pulmonary capillary transit time and haemodynamic and injection parameters was assessed using angiograms from 84 Glenn patients. Five independent observers calculated pulmonary capillary transit time to measure reproducibility (intraclass correlation coefficient). RESULTS: Mean pulmonary capillary transit time was 3.3 cardiac cycles in the control population, and 3.5, 2.4, and 3.5 in the pre-Glenn, Glenn, and Fontan stages, respectively. Pulmonary capillary transit time in the Glenn population did not correlate with injection conditions. Intraclass correlation coefficient was 0.87. CONCLUSIONS: Pulmonary angiography can be used to calculate the pulmonary capillary transit time, which is reproducible between observers. Pulmonary capillary transit time accelerates in the Glenn stage, correlating with absence of direct hepatopulmonary venous flow.

2.
medRxiv ; 2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38260565

RESUMO

Background: Individuals with single ventricle physiology who are palliated with superior cavopulmonary anastomosis (Glenn surgery) may develop pulmonary arteriovenous malformations (PAVMs). The traditional tools for PAVM diagnosis are often of limited diagnostic utility in this patient population. We sought to measure the pulmonary capillary transit time (PCTT) to determine its value as a tool to identify PAVMs in patients with single ventricle physiology. Methods: We defined the angiographic PCTT as the number of cardiac cycles required for transit of contrast from the distal pulmonary arteries to the pulmonary veins. Patients were retrospectively recruited from a single quaternary North American pediatric center, and angiographic and clinical data was reviewed. PCTT was calculated in 20 control patients and compared to 20 single ventricle patients at the pre-Glenn, Glenn, and Fontan surgical stages (which were compared with a linear-mixed model). Correlation (Pearson) between PCTT and hemodynamic and injection parameters was assessed using 84 Glenn angiograms. Five independent observers calculated PCTT to measure reproducibility (intra-class correlation coefficient). Results: Mean PCTT was 3.3 cardiac cycles in the control population, and 3.5, 2.4, and 3.5 in the pre-Glenn, Glenn, and Fontan stages, respectively. PCTT in the Glenn population did not correlate with injection conditions. Intraclass correlation coefficient was 0.87. Conclusions: Pulmonary angiography can be used to calculate the pulmonary capillary transit time, which is reproducible between observers. PCTT accelerates in the Glenn stage, correlating with absence of direct hepatopulmonary venous flow.

3.
J Cardiovasc Magn Reson ; 24(1): 32, 2022 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-35650624

RESUMO

INTRODUCTION: Cardiovascular magnetic resonance (CMR)-guided cardiac catheterization is becoming more widespread due to the ability to acquire both functional CMR measurements and diagnostic catheterization data without exposing patients to ionizing radiation. However, the real-time imaging sequences used for catheter guidance during these procedures are limited in resolution and the anatomical detail they can provide. In this study, we propose a passive catheter tracking approach which simultaneously improves catheter tracking and visualization of the anatomy. METHODS: 60 patients with congenital heart disease underwent CMR-guided cardiac catheterization on a 1.5T CMR scanner (Ingenia, Philips Healthcare, Best the Netherlands) using the Philips iSuite system. The proposed T1-overlay technique uses a commercially available heavily T1-weighted sequence to image the catheter, and overlays it on a high-resolution 3D dataset within iSuite in real-time. Suppressed tissue in the real-time images enables the use of a thick imaging slab to assist in tracking of the catheter. Improvement in catheter visualization time was compared between T1-overlay and the conventional invasive CMR (iCMR) balanced steady state free precession (bSSFP) sequence. This technique also enabled selective angiography visualization for real-time evaluation of blood flow dynamics (such as pulmonary transit time), similar to direct contrast injection under standard fluoroscopy. Estimates of pulmonary transit time using iCMR were validated using x-ray fluoroscopy in 16 patients. RESULTS: The T1-overlay approach significantly increased the time that the catheter tip was kept in view by the technologist compared to the bSSFP sequence conventionally used for iCMR. The resulting images received higher ratings for blood/balloon contrast, anatomy visualization, and overall suitability for iCMR guidance by three cardiologists. iCMR selective angiography using T1-overlay also provided accurate estimates of pulmonary transit time that agreed well with x-ray fluoroscopy. CONCLUSION: We demonstrate a new passive catheter tracking technique using the iSuite platform that improves visualization of the catheter and cardiac anatomy. These improvements significantly increase the time that the catheter tip is seen throughout the procedure. We also demonstrate the feasibility of iCMR selective angiography for the measurement of pulmonary transit time.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Cateterismo Cardíaco/métodos , Catéteres , Humanos , Imagem por Ressonância Magnética Intervencionista/métodos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes
4.
Children (Basel) ; 9(4)2022 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-35455541

RESUMO

Transcatheter device intervention is now offered as first line therapy for many congenital heart defects (CHD) which were traditionally treated with cardiac surgery. While off-label use of devices is common and appropriate, a growing number of devices are now specifically designed and approved for use in CHD. Advanced imaging is now an integral part of interventional procedures including pre-procedure planning, intra-procedural guidance, and post-procedure monitoring. There is robust societal and industrial support for research and development of CHD-specific devices, and the regulatory framework at the national and international level is patient friendly. It is against this backdrop that we review transcatheter implantable devices for CHD, the role and integration of advanced imaging, and explore the current regulatory framework for device approval.

5.
Children (Basel) ; 9(3)2022 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-35327672

RESUMO

Management of congenital heart disease (CHD) has recently increased utilization of cross-sectional imaging to plan percutaneous interventions. Cardiac computed tomography (CT) and cardiac magnetic resonance (CMR) imaging have become indispensable tools for pre-procedural planning prior to intervention in the pediatric cardiac catheterization lab. In this article, we review several common indications for referral and the impact of cross-sectional imaging on procedural planning, success, and patient surveillance.

6.
Cardiol Young ; : 1-6, 2021 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-34663483

RESUMO

Patent ductus arteriosus stenting for ductal-dependent pulmonary blood flow is a technically challenging neonatal procedure to maintain a stable pulmonary circulation. Pre-procedural computed tomography imaging aids in outlining ductal origin, insertion, size, course and curvature. Computed tomography imaging may add value to procedural outcomes and reduce overall procedural morbidity in neonatal patent ductus arteriosus stenting. We conducted a single centre retrospective chart review of neonates with ductal-dependent pulmonary blood flow who underwent patent ductus arteriosus stenting between January 1, 2014 and June 31, 2020. We compared patients variables between patients who underwent pre-procedural computed tomography imaging to those who did not. A total of 64 patients were referred for patent ductus arteriosus stenting with 33 (52%) obtaining pre-procedural computed tomography imaging. Average age [19 days; range 1-242 days (p = 0.85)] and weight [3.3 kg (range 2.2-6.0 kg; p = 0.19)] was not significantly different between the groups. A diagnosis of pulmonary atresia was made in 42 out of 64 (66%) patients prior to patent ductus arteriosus stenting. The cohort with pre-intervention computed tomography imaging had a significant reduction in the total number of access sites (1.2 versus 1.5; p = 0.03), contrast needed (5.9 versus 8.2 ml/kg; p = 0.008), fluoroscopy (20.7 versus 38.8 minutes; p = 0.02) and procedural time (83.4-128.4 minutes; p = 0.002) for the intervention. There was no significant difference in radiation burden between the groups (p = 0.35). Pre-procedural computed tomography imaging adds value by aiding interventional planning for neonatal patent ductus arteriosus stenting. A statistically significant reduction in the number of access sites, contrast exposure, as well as fluoroscopic and procedural time was noted without significantly increasing the cumulative radiation burden.

7.
J Cardiovasc Magn Reson ; 23(1): 95, 2021 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-34275477

RESUMO

BACKGROUND: Cardiac catheterization and cardiovascular magnetic resonance (CMR) imaging have distinct diagnostic roles in the congenital heart disease (CHD) population. Invasive CMR (iCMR) allows for a more thorough assessment of cardiac hemodynamics at the same time under the same conditions. It is assumed but not proven that iCMR gives an incremental value by providing more accurate flow quantification. METHODS: Subjects with CHD underwent real-time 1.5 T iCMR using a passive catheter tracking technique with partial saturation pulse of 40° to visualize the gadolinium-filled balloon, CMR-conditional guidewire, and cardiac structures simultaneously to aid in completion of right (RHC) and left heart catheterization (LHC). Repeat iCMR and catheterization measurements were performed to compare reliability by the Pearson (PCC) and concordance correlation coefficients (CCC). RESULTS: Thirty CHD (20 single ventricle and 10 bi-ventricular) subjects with a median age and weight of 8.3 years (2-33) and 27.7 kg (9.2-80), respectively,  successfully underwent iCMR RHC and LHC. No catheter related complications were encountered. Time taken for first pass RHC and LHC/aortic pull back was 5.1, and 2.9 min, respectively. Total success rate to obtain required data points to complete Fick principle calculations for all patients was 321/328 (98%). One patient with multiple shunts was an outlier and excluded from further analysis. The PCC for catheter-derived pulmonary blood flow (Qp) (0.89, p < 0.001) is slightly lower than iCMR-derived Qp (0.96, p < 0.001), whereas catheter-derived systemic blood flow (Qs) (0.62, p = < 0.001) was considerably lower than iCMR-derived Qs (0.94, p < 0.001). CCC agreement for Qp at baseline (C1-CCC = 0.65, 95% CI 0.41-0.81) and retested conditions (C2-CCC = 0.78, 95% CI 0.58-0.89) were better than for Qs at baseline (C1-CCC = 0.22, 95% CI - 0.15-0.53) and retested conditions (C2-CCC = 0.52, 95% CI 0.17-0.76). CONCLUSION: This study further validates hemodynamic measurements obtained via iCMR. iCMR-derived flows have considerably higher test-retest reliability for Qs. iCMR evaluations allow for more reproducible hemodynamic assessments in the CHD population.


Assuntos
Imageamento por Ressonância Magnética , Circulação Pulmonar , Cateterismo Cardíaco , Humanos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
8.
Pediatr Radiol ; 51(8): 1311-1321, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33791838

RESUMO

BACKGROUND: Pediatric heart transplant patients require cardiac catheterization to monitor for coronary allograft vasculopathy. Cardiac catheterization has no safe and consistent method for measuring microvascular disease. Stress perfusion cardiac magnetic resonance imaging (MRI) assessing microvascular disease has been performed in adults. OBJECTIVE: To investigate the feasibility and safety of performing cardiac MRI with quantitative adenosine stress perfusion testing in pediatric heart transplant patients with and without coronary allograft vasculopathy. MATERIALS AND METHODS: All pediatric heart transplant patients with coronary vasculopathy at our institution were asked to participate. Age- and gender-matched pediatric heart transplant patients without vasculopathy were recruited for comparison. Patients underwent cardiac MRI with adenosine stress perfusion testing. RESULTS: Sixteen pediatric heart transplant patients, ages 6-22 years, underwent testing. Nine patients had vasculopathy by angiography. No heart block or other complications occurred during the study. The myocardial perfusion reserve for patients with vasculopathy showed no significant difference with comparison patients (median: 1.43 vs. 1.48; P=0.49). Values for both groups were lower than expected values based on previous adult studies. The patients were also analyzed for time after transplant and the number of rejection episodes. Patients within 6 years of transplantation had a nonsignificant trend toward a higher myocardial perfusion reserve (median: 1.57) versus patients with older transplants (median: 1.47; P=0.46). Intra- and interobserver reproducibility were 97% and 92%, respectively. CONCLUSION: Myocardial perfusion reserve is a safe and feasible method for estimating myocardial perfusion in pediatric heart transplant patients. There is no reliable way to monitor microvascular disease in pediatric patients. This method shows potential and deserves investigation in a larger cohort.


Assuntos
Doença da Artéria Coronariana , Transplante de Coração , Adenosina , Adolescente , Adulto , Aloenxertos , Criança , Angiografia Coronária , Estudos de Viabilidade , Humanos , Imageamento por Ressonância Magnética , Perfusão , Reprodutibilidade dos Testes , Adulto Jovem
10.
J Cardiovasc Magn Reson ; 23(1): 16, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33641664

RESUMO

BACKGROUND: Due to passive blood flow in palliated single ventricle, central venous pressure increases chronically, ultimately impeding lymphatic drainage. Early visualization and treatment of these malformations is essential to reduce morbidity and mortality. Cardiovascular magnetic resonance (CMR) T2-weighted lymphangiography (T2w) is used for lymphatic assessment, but its low signal-to-noise ratio may result in incomplete visualization of thoracic duct pathway. 3D-balanced steady state free precession (3D-bSSFP) is commonly used to assess congenital cardiac disease anatomy. Here, we aimed to improve diagnostic imaging of thoracic duct pathway using 3D-bSSFP. METHODS: Patients underwent CMR during single ventricle or central lymphatic system assessment using T2w and 3D-bSSFP. T2w parameters included 3D-turbo spin echo (TSE), TE/TR = 600/2500 ms, resolution = 1 × 1 × 1.8 mm, respiratory triggering with bellows. 3D-bSSFP parameters included electrocardiogram triggering and diaphragm navigator, 1.6 mm isotropic resolution, TE/TR = 1.8/3.6 ms. Thoracic duct was identified independently in T2w and 3D-bSSFP images, tracked completely from cisterna chyli to its drainage site, and classified based on severity of lymphatic abnormalities. RESULTS: Forty-eight patients underwent CMR, 46 of whom were included in the study. Forty-five had congenital heart disease with single ventricle physiology. Median age at CMR was 4.3 year (range 0.9-35.1 year, IQR 2.4 year), and median weight was 14.4 kg (range, 7.9-112.9 kg, IQR 5.2 kg). Single ventricle with right dominant ventricle was noted in 31 patients. Thirty-eight patients (84%) were status post bidirectional Glenn and 7 (16%) were status post Fontan anastomosis. Thoracic duct visualization was achieved in 45 patients by T2w and 3D-bSSFP. Complete tracking to drainage site was attained in 11 patients (24%) by T2w vs 25 (54%) by 3D-bSSFP and in 28 (61%) by both. Classification of lymphatics was performed in 31 patients. CONCLUSION: Thoracic duct pathway can be visualized by 3D-bSSFP combined with T2w lymphangiography. Cardiac triggering and respiratory navigation likely help retain lymphatic signal in the retrocardiac area by 3D-bSSFP. Visualizing lymphatic system leaks is challenging on 3D-bSSFP images alone, but 3D-bSSFP offers good visualization of duct anatomy and landmark structures to help plan interventions. Together, these sequences can define abnormal lymphatic pathway following single ventricle palliative surgery, thus guiding lymphatic interventional procedures.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Imageamento Tridimensional , Linfografia , Imageamento por Ressonância Magnética , Ducto Torácico/diagnóstico por imagem , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Cardiopatias Congênitas/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Lactente , Masculino , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Ducto Torácico/fisiopatologia , Adulto Jovem
12.
J Magn Reson Imaging ; 53(5): 1446-1457, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33155758

RESUMO

BACKGROUND: Improvements in outcomes for patients with congenital heart disease (CHD) have increased the need for diagnostic and interventional procedures. Cumulative radiation risk is a growing concern. MRI-guided interventions are a promising ionizing radiation-free, alternative approach. PURPOSE: To assess the feasibility of MRI-guided catheterization in young patients with CHD using advanced visualization passive tracking techniques. STUDY TYPE: Prospective. POPULATION: A total of 30 patients with CHD referred for MRI-guided catheterization and pulmonary vascular resistance analysis (median age/weight: 4 years / 15 kg). FIELD STRENGTH/SEQUENCE: 1.5T; partially saturated (pSAT) real-time single-shot balanced steady-state free-precession (bSSFP) sequence. ASSESSMENT: Images were visualized by a single viewer on the scanner console (interactive mode) or using a commercially available advanced visualization platform (iSuite, Philips). Image quality for anatomy and catheter visualization was evaluated by three cardiologists with >5 years' experience in MRI-catheterization using a 1-5 scale (1, poor, 5, excellent). Catheter balloon signal-to-noise ratio (SNR), blood and myocardium SNR, catheter balloon/blood contrast-to-noise ratio (CNR), balloon/myocardium CNR, and blood/myocardium CNR were measured. Procedure findings, feasibility, and adverse events were recorded. A fraction of time in which the catheter was visible was compared between iSuite and the interactive mode. STATISTICAL TESTS: T-test for numerical variables. Wilcoxon signed rank test for categorical variables. RESULTS: Nine patients had right heart catheterization, 11 had both left and right heart catheterization, and 10 had single ventricle circulation. Nine patients underwent solely MRI-guided catheterization. The mean score for anatomical visualization and contrast between balloon tip and soft tissue was 3.9 ± 0.9 and 4.5 ± 0.7, respectively. iSuite provided a significant improvement in the time during which the balloon was visible in relation to interactive imaging mode (66 ± 17% vs. 46 ± 14%, P < 0.05). DATA CONCLUSION: MRI-guided catheterizations were carried out safely and is feasible in children and adults with CHD. The pSAT sequence offered robust and simultaneous high contrast visualization of the catheter and cardiac anatomy. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 1.


Assuntos
Cardiopatias Congênitas , Imagem por Ressonância Magnética Intervencionista , Adulto , Cateterismo Cardíaco , Criança , Pré-Escolar , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Estudos Prospectivos
13.
Medicina (Kaunas) ; 56(12)2020 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-33255307

RESUMO

The interventional cardiac magnetic resonance imaging (iCMR) catheterization procedure is feasible and safe for children and adults with pulmonary hypertension and congenital heart defects (CHD). With iCMR, the calculation of pulmonary vascular resistance (PVR) in children with complex CHD with multilevel shunt lesions is accurate. In this paper, we describe the role of the MRI-guided right-sided cardiac catheterization procedure to accurately estimate PVR in the setting of multiple shunt lesions (ventricular septal defect and patent ductus arteriosus) and to address the clinical question of operability in an adolescent with trisomy 21 and severe pulmonary hypertension.


Assuntos
Permeabilidade do Canal Arterial , Cardiopatias Congênitas , Hipertensão Pulmonar , Adolescente , Adulto , Criança , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/diagnóstico por imagem , Imageamento por Ressonância Magnética , Resistência Vascular
14.
Cardiol Young ; 30(11): 1747-1749, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32880248

RESUMO

Prosthetic valve thrombosis is a serious complication of prosthetic heart valves that typically requires either surgical intervention or systemic thrombolysis. In patients with contraindications to both treatment modalities, options can be limited. We describe an alternative approach to managing prosthetic valve thrombosis in an infant presenting in extremis with pulmonary haemorrhage. Using transoesophageal echocardiography and fluoroscopic guidance, we restored function to the infant's obstructed St. Jude prosthetic mitral valve through percutaneous transcatheter manipulation of the valve's leaflets.


Assuntos
Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Trombose , Ecocardiografia Transesofagiana , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Lactente , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Trombose/etiologia
15.
Cardiol Young ; 30(5): 656-662, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32290877

RESUMO

Novel commercially available software has enabled registration of both CT and MRI images to rapidly fuse with X-ray fluoroscopic imaging. We describe our initial experience performing cardiac catheterisations with the guidance of 3D imaging overlay using the VesselNavigator system (Philips Healthcare, Best, NL). A total of 33 patients with CHD were included in our study. Demographic, advanced imaging, and catheterisation data were collected between 1 December, 2016 and 31 January, 2019. We report successful use of this technology in both diagnostic and interventional cases such as placing stents and percutaneous valves, performing angioplasties, occlusion of collaterals, and guidance for lymphatic interventions. In addition, radiation exposure was markedly decreased when comparing our 10-15-year-old coarctation of the aorta stent angioplasty cohort to cases without the use of overlay technology and the most recently published national radiation dose benchmarks. No complications were encountered due to the application of overlay technology. 3D CT or MRI overlay for CHD intervention with rapid registration is feasible and aids decisions regarding access and planned angiographic angles. Operators found intraprocedural overlay fusion registration using placed vessel guidewires to be more accurate than attempts using bony structures.


Assuntos
Cateterismo Cardíaco/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Lactente , Recém-Nascido , Masculino , Imagem Multimodal , Estudos Retrospectivos , Software , Adulto Jovem
16.
J Cardiovasc Magn Reson ; 22(1): 20, 2020 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-32213193

RESUMO

BACKGROUND: Today's standard of care, in the congenital heart disease (CHD) population, involves performing cardiac catheterization under x-ray fluoroscopy and cardiac magnetic resonance (CMR) imaging separately. The unique ability of CMR to provide real-time functional imaging in multiple views without ionizing radiation exposure has the potential to be a powerful tool for diagnostic and interventional procedures. Limiting fluoroscopic radiation exposure remains a challenge for pediatric interventional cardiologists. This pilot study's objective is to establish feasibility of right (RHC) and left heart catheterization (LHC) during invasive CMR (iCMR) procedures at our institution in the CHD population. Furthermore, we aim to improve simultaneous visualization of the catheter balloon tip, MR-conditional guidewire, and cardiac/vessel anatomy during iCMR procedures. METHODS: Subjects with CHD were enrolled in a pilot study for iCMR procedures at 1.5 T with an MR-conditional guidewire. The CMR area is located adjacent to a standard catheterization laboratory. Using the interactive scanning mode for real-time control of the imaging location, a dilute gadolinium-filled balloon-tip catheter was used in combination with an MR-conditional guidewire to obtain cardiac saturations and hemodynamics. A recently developed catheter tracking technique using a real-time single-shot balanced steady-state free precession (bSSFP), flip angle (FA) 35-45°, echo time (TE) 1.3 ms, repetition time (TR) 2.7 ms, 40° partial saturation (pSAT) pre-pulse was used to visualize the gadolinium-filled balloon, MR-conditional guidewire, and cardiac structures simultaneously. MR-conditional guidewire visualization was enabled due to susceptibility artifact created by distal markers. Pre-clinical phantom testing was performed to determine the optimum imaging FA-pSAT combination. RESULTS: The iCMR procedure was successfully performed to completion in 31/34 (91%) subjects between August 1st, 2017 to December 13th, 2018. Median age and weight were 7.7 years and 25.2 kg (range: 3 months - 33 years and 8 - 80 kg). Twenty-one subjects had single ventricle (SV) anatomy: one subject was referred for pre-Glenn evaluation, 11 were pre-Fontan evaluations and 9 post-Fontan evaluations for protein losing enteropathy (PLE) and/or cyanosis. Thirteen subjects had bi-ventricular (BiV) anatomy, 4 were referred for coarctation of the aorta (CoA) evaluations, 3 underwent vaso-reactivity testing with inhaled nitric oxide, 3 investigated RV volume dimensions, two underwent branch PA stenosis evaluation, and the remaining subject was status post heart transplant. No catheter related complications were encountered. Average time taken for first pass RHC, LHC/aortic pull back, and to cross the Fontan fenestration was 5.2, 3.0, and 6.5 min, respectively. Total success rate to obtain required data points to complete Fick principle calculations for all patients was 331/337 (98%). Subjects were transferred to the x-ray fluoroscopy lab if further intervention was required including Fontan fenestration device closure, balloon angioplasty of pulmonary arteries/conduits, CoA stenting, and/or coiling of aortopulmonary (AP) collaterals. Starting with subject #10, an MR-conditional guidewire was used in all subsequent subjects (15 SV and 10 BiV) with a success rate of 96% (24/25). Real-time CMR-guided RHC (25/25 subjects, 100%), retrograde and prograde LHC/aortic pull back (24/25 subjects, 96%), CoA crossing (3/4 subjects, 75%) and Fontan fenestration test occlusion (2/3 subjects, 67%) were successfully performed in the majority of subjects when an MR-conditional guidewire was utilized. CONCLUSION: Feasibility for detailed diagnostic RHC, LHC, and Fontan fenestration test occlusion iCMR procedures in SV and BiV pediatric subjects with complex CHD is demonstrated with the aid of an MR-conditional guidewire. A novel real-time pSAT GRE sequence with optimized FA-pSAT angle has facilitated simultaneous visualization of the catheter balloon tip, MR-conditional guidewire, and cardiac/vessel anatomy during iCMR procedures.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Cardiopatias Congênitas/diagnóstico , Imagem por Ressonância Magnética Intervencionista/instrumentação , Adolescente , Adulto , Criança , Pré-Escolar , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/terapia , Humanos , Lactente , Masculino , Imagens de Fantasmas , Projetos Piloto , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Adulto Jovem
17.
Clin Chim Acta ; 440: 87-92, 2015 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-25444751

RESUMO

BACKGROUND: ADAMTS 13, sP-Selectin and HSP27 have been investigated as potential prognostic markers in patients with hemorrhagic shock. METHODS: This study was part of a double-blind, randomized, parallel-group, controlled trial and included seventeen trauma patients presented to ED with severe hemorrhagic. The sera for testing were collected from these patients at the time of admission. Investigators and laboratory personnel performing testing were blinded to the patients' identity and clinical course. RESULTS: The prognostic value of ADAMTS13, sP-Selectin, and HSP27 was compared to prognostic value of systolic blood pressure (SBP), base deficit estimation (BD), heart rate (HR), shock index (SI) and tissue oxygen saturation (StO2) by constructing the receiver operation characteristics (ROC). The area under the curve (AUC) of the ROC for HSP27 (0.92) was greater than for SBP (0.45), BD (0.89), HR (0.61), SI (0.45) and StO2 (0.46). AUC for sP-Selectin (0.86) and for ADAMTS13 antigen (0.74) were comparable with BD one, but greater than for the rest of currently used tests. CONCLUSION: Serum concentrations of ADAMTS13, HSP27 and sP-Selectin measured during the admission, appear to be comparable to or better than SBP, BD, SI, HR and StO2 in predicting MODS and death after hemorrhage from trauma. These potential new markers deserve further investigation.


Assuntos
Biomarcadores/análise , Insuficiência de Múltiplos Órgãos/mortalidade , Insuficiência de Múltiplos Órgãos/fisiopatologia , Choque Hemorrágico/complicações , Proteínas ADAM/sangue , Proteína ADAMTS13 , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Biomarcadores/sangue , Pressão Sanguínea , Feminino , Proteínas de Choque Térmico HSP27/sangue , Frequência Cardíaca , Proteínas de Choque Térmico , Humanos , Masculino , Pessoa de Meia-Idade , Chaperonas Moleculares , Selectina-P/sangue , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Choque Hemorrágico/fisiopatologia , Adulto Jovem
18.
J Trauma Acute Care Surg ; 77(1): 166-9, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24977773

RESUMO

BACKGROUND: Head injury is the most common cause of neurologic disability and mortality in children. Previous studies have demonstrated that depressed skull fractures (SFs) represent approximately one quarter of all SFs in children and approximately 10% percent of hospital admissions after head injury. We hypothesized that nondepressed SFs (NDSFs) in children are not associated with adverse neurologic outcomes. METHODS: Medical records were reviewed for all children 5 years or younger with SFs who presented to our Level I trauma center during a 4-year period. Data collected included patient demographics, Glasgow Coma Scale (GCS) score at admission, level of consciousness at the time of injury, type of SF (depressed SF vs. NDSF), magnitude of the SF depression, evidence of neurologic deficit, and the requirement for neurosurgical intervention. RESULTS: We evaluated 1,546 injured young children during the study period. From this cohort, 563 had isolated head injury, and 223 of them had SF. Of the SF group, 163 (73%) had NDSFs, of whom 128 (78%) presented with a GCS score of 15. None of the NDSF patients with a GCS score of 15 required neurosurgical intervention or developed any neurologic deficit. Of the remaining 35 patients with NDSF and GCS score less than 15, 7 (20%) had a temporary neurologic deficit that resolved before discharge, 4 (11%) developed a persistent neurologic deficit, and 2 died (6%). CONCLUSION: Children 5 years or younger with NDSFs and a normal neurologic examination result at admission do not develop neurologic deterioration. LEVEL OF EVIDENCE: Epidemiological study, level III.


Assuntos
Fraturas Cranianas/complicações , Fraturas Cranianas/diagnóstico , Criança , Pré-Escolar , Feminino , Escala de Coma de Glasgow , Humanos , Lactente , Recém-Nascido , Tempo de Internação , Masculino , Exame Neurológico , Fraturas Cranianas/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...