Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Diagnostics (Basel) ; 11(6)2021 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-34208531

RESUMO

RATIONALE: To formally determine the repeatability of Ga-68 PSMA lesion uptake in both relapsing and metastatic tumor. In addition, it was hypothesized that the BPL algorithm Q. Clear has the ability to lower SUV signal variability in the small lesions typically encountered in Ga-68 PSMA PET imaging of prostate cancer. METHODS: Patients with biochemical recurrence of prostate cancer were prospectively enrolled in this single center pilot test-retest study and underwent two Ga-68 PSMA PET/CT scans within 7.9 days on average. Lesions were classified as suspected local recurrence, lymph node metastases or bone metastases. Two datasets were generated: one standard PSF + OSEM and one with PSF + BPL reconstruction algorithm. For tumor lesions, SUVmax was determined. Repeatability was formally assessed using Bland-Altman analysis for both BPL and standard reconstruction. RESULTS: A total number of 65 PSMA-positive tumor lesions were found in 23 patients (range 1 to 12 lesions a patient). Overall repeatability in the 65 lesions was -1.5% ± 22.7% (SD) on standard reconstructions and -2.1% ± 29.1% (SD) on BPL reconstructions. Ga-68 PSMA SUVmax had upper and lower limits of agreement of +42.9% and -45.9% for standard reconstructions and +55.0% and -59.1% for BPL reconstructions, respectively (NS). Tumor SUVmax repeatability was dependent on lesion area, with smaller lesions exhibiting poorer repeatability on both standard and BPL reconstructions (F-test, p < 0.0001). CONCLUSION: A minimum response of 50% seems appropriate in this clinical situation. This is more than the recommended 30% for other radiotracers and clinical situations (PERCIST response criteria). BPL does not seem to lower signal variability in these cases.

3.
Diagnostics (Basel) ; 11(5)2021 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-34066854

RESUMO

Functional imaging with 68Ga prostate-specific membrane antigen (PSMA) and positron emission tomography (PET) can fulfill an important role in treatment selection and adjustment in prostate cancer. This article focusses on quantitative assessment of 68Ga-PSMA-PET. The effect of various parameters on standardized uptake values (SUVs) is explored, and an optimal Bayesian penalized likelihood (BPL) reconstruction is suggested. PET acquisitions of two phantoms consisting of a background compartment and spheres with diameter 4 mm to 37 mm, both filled with solutions of 68Ga in water, were performed with a GE Discovery 710 PET/CT scanner. Recovery coefficients (RCs) in multiple reconstructions with varying noise penalty factors and acquisition times were determined and analyzed. Apparent recovery coefficients of spheres with a diameter smaller than 17 mm were significantly lower than those of spheres with a diameter of 17 mm and bigger (p < 0.001) for a tumor-to-background (T/B) ratio of 10:1 and a scan time of 10 min per bed position. With a T/B ratio of 10:1, the four largest spheres exhibit significantly higher RCs than those with a T/B ratio of 20:1 (p < 0.0001). For spheres with a diameter of 8 mm and less, alignment with the voxel grid potentially affects the RC. Evaluation of PET/CT scans using (semi-)quantitative measures such as SUVs should be performed with great caution, as SUVs are influenced by scanning and reconstruction parameters. Based on the evaluation of multiple reconstructions with different ß of phantom scans, an intermediate ß (600) is suggested as the optimal value for the reconstruction of clinical 68Ga-PSMA PET/CT scans, considering that both detectability and reproducibility are relevant.

4.
EJNMMI Phys ; 6(1): 32, 2019 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-31889228

RESUMO

BACKGROUND: Recently, a Bayesian penalized likelihood (BPL) reconstruction algorithm was introduced for a commercial PET/CT with the potential to improve image quality. We compared the performance of this BPL algorithm with conventional reconstruction algorithms under realistic clinical conditions such as daily practiced at many European sites, i.e. low 18F-FDG dose and short acquisition times. RESULTS: To study the performance of the BPL algorithm, regular clinical 18F-FDG whole body PET scans were made. In addition, two types of phantoms were scanned with 4-37 mm sized spheres filled with 18F-FDG at sphere-to-background ratios of 10-to-1, 4-to-1, and 2-to-1. Images were reconstructed using standard ordered-subset expectation maximization (OSEM), OSEM with point spread function (PSF), and the BPL algorithm using ß-values of 450, 550 and 700. To quantify the image quality, the lesion detectability, activity recovery, and the coefficient of variation (COV) within a single bed position (BP) were determined. We found that when applying the BPL algorithm both smaller lesions in clinical studies as well as spheres in phantom studies can be detected more easily due to a higher SUV recovery, especially for higher contrast ratios. Under standard clinical scanning conditions, i.e. low number of counts, the COV is higher for the BPL (ß=450) than the OSEM+PSF algorithm. Increase of the ß-value to 550 or 700 results in a COV comparable to OSEM+PSF, however, at the cost of contrast, though still better than OSEM+PSF. At the edges of the axial field of view (FOV) where BPs overlap, COV can increase to levels at which bands become visible in clinical images, related to the lower local axial sensitivity of the PET/CT, which is due to the limited bed overlap of 23% such as advised by the manufacturer. CONCLUSIONS: The BPL algorithm performs better than the standard OSEM+PSF algorithm on small lesion detectability, SUV recovery, and noise suppression. Increase of the percentage of bed overlap, time per BP, administered activity, or the ß-value, all have a direct positive impact on image quality, though the latter with some loss of small lesion detectability. Thus, BPL algorithms are very interesting for improving image quality, especially in small lesion detectability.

5.
Eur J Nucl Med Mol Imaging ; 44(Suppl 1): 4-16, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28687866

RESUMO

In recent years, there have been multiple advances in positron emission tomography/computed tomography (PET/CT) that improve cancer imaging. The present generation of PET/CT scanners introduces new hardware, software, and acquisition methods. This review describes these new developments, which include time-of-flight (TOF), point-spread-function (PSF), maximum-a-posteriori (MAP) based reconstruction, smaller voxels, respiratory gating, metal artefact reduction, and administration of quadratic weight-dependent 18F-fluorodeoxyglucose (FDG) activity. Also, hardware developments such as continuous bed motion (CBM), (digital) solid-state photodetectors and combined PET and magnetic resonance (MR) systems are explained. These novel techniques have a significant impact on cancer imaging, as they result in better image quality, improved small lesion detectability, and more accurate quantification of radiopharmaceutical uptake. This influences cancer diagnosis and staging, as well as therapy response monitoring and radiotherapy planning. Finally, the possible impact of these developments on the European Association of Nuclear Medicine (EANM) guidelines and EANM Research Ltd. (EARL) accreditation for FDG-PET/CT tumor imaging is discussed.


Assuntos
Tomografia por Emissão de Pósitrons/métodos , Artefatos , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Imagem Multimodal
6.
J Endourol ; 22(10): 2227-34, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18831670

RESUMO

BACKGROUND AND PURPOSE: Several kinds of flexible ureteroscopes are in use for the removal of kidney stones. This study evaluated and compared the characteristics of four new-generation flexible ureteroscopes. MATERIALS AND METHODS: The flexible ureteroscopes studied were: the ACMI Dur-8 Elite, the Storz Flex-X2 the Olympus XURF-P5, and the Wolf 7325.076. Measured properties included (de)flection, instrument insertion, flow properties, torsion stiffness, and optical characteristics. Active tip deflection and irrigation flow rates with and without various endoscopic tools were assessed. RESULTS: All ureteroscopes score better on (de)flection with an empty working channel, compared with a channel when tools are inserted (differences minimum 0.3 degrees--maximum 80.6 degrees). The Olympus XURF-P5 is the only ureteroscope with passive (de)flection capability, whereas the ACMI DUR-8 Elite is the only ureteroscope that has a secondary active (de)flection capability. The Storz Flex-X2 and the Wolf 7325.076 ureteroscopes show nearly identical best deflection capabilities with and without tools inserted in the working channel. The longest (Olympus XURF-P5, 70 cm) and shortest (ACMI DUR-8 Elite, 64 cm) ureteroscopes have, respectively, the lowest and highest flow rates. Best optical quality is offered by the Olympus XURF-P5 and Wolf 7325.076 ureteroscopes, which have low optical distortion (-9.7; -7.7%), high resolving power (17.95; 16.00 line pairs per millimeter), and a large field of view (62.9; 63.2 degrees). The Storz Flex-X2 and Wolf 7325.076 ureteroscopes have lowest torsion stiffness. CONCLUSIONS: The ex vivo evaluation of the deflection capabilities, passage of instruments, flow properties, torsion stiffness, and optical characteristics yielded quantitative measures of the in vivo performance capabilities of four new-generation flexible ureteroscopes. New ureteroscopes should be subjected to this or similar evaluation and comparison. Only in this way can the urologist make an informed and objective decision regarding appropriate instrument choice.


Assuntos
Maleabilidade , Torção Mecânica , Ureteroscópios , Fenômenos Ópticos , Reologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...