Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
IEEE Trans Med Imaging ; 41(11): 2980-2990, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35584078

RESUMO

Breast microcalcifications are an important primary radiological indicator of breast cancer. However, microcalcification classification and diagnosis may be still challenging for radiologists due to limitations of the standard 2D mammography technique, including spatial and contrast resolution. In this study, we propose an approach to improve the detection of microcalcifications in propagation-based phase-contrast X-ray computed tomography of breast tissues. Five fresh mastectomies containing microcalcifications were scanned at different X-ray energies and radiation doses using synchrotron radiation. Both bright-field (i.e. conventional phase-retrieved images) and dark-field images were extracted from the same data sets using different image processing methods. A quantitative analysis was performed in terms of visibility and contrast-to-noise ratio of microcalcifications. The results show that while the signal-to-noise and the contrast-to-noise ratios are lower, the visibility of the microcalcifications is more than two times higher in the dark-field images compared to the bright-field images. Dark-field images have also provided more accurate information about the size and shape of the microcalcifications.


Assuntos
Doenças Mamárias , Neoplasias da Mama , Calcinose , Humanos , Feminino , Mamografia/métodos , Calcinose/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem
2.
Phys Med Biol ; 65(21): 215029, 2020 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-32756030

RESUMO

A method for extracting the dark-field signal in propagation-based phase-contrast imaging is proposed. In the case of objects consisting predominantly of a single material, or several different materials with similar ratios of the real decrement to the imaginary part of the complex refractive index, the proposed method requires a single image for extraction of the dark-field signal in two-dimensional projection imaging. In the case of three-dimensional tomographic imaging, the method needs only one image to be collected at each projection angle. Initial examples using simulated and experimental data indicate that this method can improve visualization of small sharp features inside a larger object, e.g. the visualization of microcalcifications in propagation-based x-ray breast cancer imaging. It is suggested that the proposed approach may be useful in other forms of biomedical imaging, where it can help one to obtain additional small-angle scattering information without increasing the radiation dose to the sample.


Assuntos
Microscopia de Contraste de Fase/métodos , Calcinose/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Refratometria , Espalhamento a Baixo Ângulo
3.
Med Phys ; 46(12): 5478-5487, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31574166

RESUMO

PURPOSE: Propagation-based phase-contrast computed tomography (PB-CT) is a method for three-dimensional x-ray imaging that utilizes refraction, as well as absorption, of x rays in the tissues to increase the signal-to-noise ratio (SNR) in the resultant images, in comparison with equivalent conventional absorption-only x-ray tomography (CT). Importantly, the higher SNR is achieved without sacrificing spatial resolution or increasing the radiation dose delivered to the imaged tissues. The present work has been carried out in the context of the current development of a breast CT imaging facility at the Australian Synchrotron. METHODS: Seven unfixed complete mastectomy samples with and without breast cancer lesions have been imaged using absorption-only CT and PB-CT techniques under controlled experimental conditions. The radiation doses delivered to the mastectomy samples during the scans were comparable to those approved for mammographic screening. Physical characteristics of the reconstructed images, such as spatial resolution and SNR, have been measured and compared with the results of the radiological quality assessment of the complete absorption CT and PB-CT image stacks. RESULTS: Despite the presence of some image artefacts, the PB-CT images have outperformed comparable absorption CT images collected at the same radiation dose, in terms of both the measured objective image characteristics and the radiological image scores. The outcomes of these experiments are shown to be consistent with predictions of the theory of PB-CT imaging and previous reported experimental studies of this imaging modality. CONCLUSIONS: The results presented in this paper demonstrate that PB-CT holds a high potential for improving on the quality and diagnostic value of images obtained using existing medical x-ray technologies, such as mammography and digital breast tomosynthesis (DBT). If implemented at suitable synchrotron imaging facilities, PB-CT can be used to complement existing imaging modalities, leading to more accurate breast cancer diagnosis.


Assuntos
Mastectomia , Síncrotrons , Tomografia Computadorizada por Raios X/instrumentação , Mama/diagnóstico por imagem , Mama/cirurgia , Feminino , Humanos , Processamento de Imagem Assistida por Computador
4.
Hear Res ; 327: 48-57, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25987505

RESUMO

AIM: To explore morphological or electrophysiological evidence for the presence of endolymphatic hydrops (EH) in guinea pig cochleae in the first 3 months after cochlear implantation. METHODS: Dummy silastic electrodes were implanted atraumatically into the basal turn of scala tympani via a cochleostomy. Round window electrocochleography (ECochG) was undertaken prior to and after implantation. Animals survived for 1, 7, 28 or 72 days prior to a terminal experiment, when ECochG was repeated. The cochleae were imaged using micro-CT after post-fixing with osmium tetroxide to reveal the inner ear soft tissue structure. EH was assessed by visual inspection at a series of frequency specific places along the length of the cochlea, and the extent to which Reissner's membrane departed from its neutral position was quantified. Tissue response volumes were calculated. Using ECochG, the ratio of the summating potential to the action potential (SP/AP ratio) was calculated in response to frequencies between 2 and 32 kHz. RESULTS: There was minimal evidence of electrode trauma from cochlear implantation on micro-CT imaging. Tissue response volumes did not change over time. EH was most prevalent 7 days after surgery in implanted ears, as determined by visual inspection. Scala media areas were increased, as expected in cases of EH, over the first month after cochlear implantation. SP/AP ratios decreased immediately after surgery, but were elevated 1 and 7 days after implantation. CONCLUSIONS: EH is prevalent in the first weeks after implant surgery, even in the absence of significant electrode insertion trauma.


Assuntos
Cóclea/cirurgia , Implante Coclear/efeitos adversos , Hidropisia Endolinfática/etiologia , Estimulação Acústica , Animais , Audiometria de Resposta Evocada , Limiar Auditivo , Cóclea/diagnóstico por imagem , Cóclea/fisiopatologia , Implante Coclear/instrumentação , Implantes Cocleares , Modelos Animais de Doenças , Hidropisia Endolinfática/diagnóstico , Hidropisia Endolinfática/fisiopatologia , Potenciais Evocados , Cobaias , Fatores de Tempo , Microtomografia por Raio-X
5.
Rev Sci Instrum ; 84(6): 063703, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23822348

RESUMO

This study realizes the concept of simultaneous micro-X-ray computed tomography and X-ray powder diffraction using a synchrotron beamline. A thin zinc metal foil was placed in the primary, monochromatic synchrotron beam to generate a divergent wave to propagate through the samples of interest onto a CCD detector for tomographic imaging, thus removing the need for large beam illumination and high spatial resolution detection. Both low density materials (kapton tubing and a piece of plant) and higher density materials (Egyptian faience) were investigated, and elemental contrast was explored for the example of Cu and Ni meshes. The viability of parallel powder diffraction using the direct beam transmitted through the foil was demonstrated. The outcomes of this study enable further development of the technique towards in situ tomography∕diffraction studies combining micrometer and crystallographic length scales, and towards elemental contrast imaging and reconstruction methods using well defined fluorescence outputs from combinations of known fluorescence targets (elements).


Assuntos
Corantes Fluorescentes/química , Metais/química , Difração de Pó/instrumentação , Síncrotrons , Tomografia por Raios X/instrumentação , Difração de Raios X/instrumentação
6.
Cell Death Dis ; 3: e362, 2012 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-22874999

RESUMO

In this paper we describe novel and specific roles for the apoptotic regulators Bcl2 and Bim in hearing and stapes development. Bcl2 is anti-apoptotic while Bim is pro-apoptotic. Characterization of the auditory systems of mice deficient for these molecules revealed that Bcl2⁻/⁻ mice suffered severe hearing loss. This was conductive in nature and did not affect sensory cells of the inner ear, with cochlear hair cells and neurons present and functional. Bcl2⁻/⁻ mice were found to have a malformed, often monocrural, porous stapes (the small stirrup-shaped bone of the middle ear), but a normally shaped malleus and incus. The deformed stapes was discontinuous with the incus and sometimes fused to the temporal bones. The defect was completely rescued in Bcl2⁻/⁻Bim⁻/⁻ mice and partially rescued in Bcl2⁻/⁻Bim⁺/⁻ mice, which displayed high-frequency hearing loss and thickening of the stapes anterior crus. The Bcl2⁻/⁻ defect arose in utero before or during the cartilage stage of stapes development. These results implicate Bcl2 and Bim in regulating survival of second pharyngeal arch or neural crest cells that give rise to the stapes during embryonic development.


Assuntos
Perda Auditiva Condutiva/metabolismo , Proteínas Proto-Oncogênicas c-bcl-2/metabolismo , Estribo/crescimento & desenvolvimento , Animais , Proteínas Reguladoras de Apoptose/deficiência , Proteínas Reguladoras de Apoptose/genética , Proteínas Reguladoras de Apoptose/metabolismo , Proteína 11 Semelhante a Bcl-2 , Orelha Média/diagnóstico por imagem , Orelha Média/patologia , Desenvolvimento Embrionário , Genótipo , Perda Auditiva Condutiva/patologia , Perda Auditiva de Alta Frequência/metabolismo , Perda Auditiva de Alta Frequência/patologia , Proteínas de Membrana/deficiência , Proteínas de Membrana/genética , Proteínas de Membrana/metabolismo , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Proteínas Proto-Oncogênicas/deficiência , Proteínas Proto-Oncogênicas/genética , Proteínas Proto-Oncogênicas/metabolismo , Proteínas Proto-Oncogênicas c-bcl-2/deficiência , Proteínas Proto-Oncogênicas c-bcl-2/genética , Radiografia , Estribo/metabolismo , Estribo/fisiopatologia
7.
Hear Res ; 287(1-2): 30-42, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22531007

RESUMO

A broader activation of auditory nerve fibres than normal using a cochlear implant contributes to poor frequency discrimination. As cochlear implants also deliver a restricted dynamic range, this hinders the ability to segregate sound sources. Better frequency coding and control over amplitude may be achieved by limiting current spread during electrical stimulation of the cochlea and positioning electrodes closer to the modiolus. Thin-film high density microelectrode arrays and conventional platinum ring electrode arrays were used to stimulate the cochlea of urethane-anaesthetized rats and responses compared. Neurophysiological recordings were taken at 197 multi-unit clusters in the central nucleus of the inferior colliculus (CIC), a site that receives direct monaural innervation from the cochlear nucleus. CIC responses to both the platinum ring and high density electrodes were recorded and differences in activity to changes in stimulation intensity, thresholds and frequency coding of neural activation were examined. The high density electrode array elicited less CIC activity at nonspecific frequency regions than the platinum ring electrode array. The high density electrode array produced significantly lower thresholds and larger dynamic ranges than the platinum ring electrode array when positioned close to the modiolus. These results suggest that a higher density of stimulation sites on electrodes that effectively 'aim' current, combined with placement closer to the modiolus would permit finer control over charge delivery. This may equate to improved frequency specific perception and control over amplitude when using future cochlear implant devices.


Assuntos
Cóclea/inervação , Implantes Cocleares , Nervo Coclear/fisiologia , Mesencéfalo/fisiologia , Microeletrodos , Animais , Vias Auditivas/fisiologia , Limiar Auditivo , Cóclea/diagnóstico por imagem , Estimulação Elétrica , Potenciais Evocados Auditivos do Tronco Encefálico , Masculino , Platina , Desenho de Prótese , Ratos , Ratos Wistar , Fatores de Tempo , Microtomografia por Raio-X
8.
Phys Med Biol ; 56(16): 5265-74, 2011 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-21791734

RESUMO

By applying a phase-retrieval step before carrying out standard filtered back-projection reconstructions in tomographic imaging, we were able to resolve structures with small differences in density within a densely absorbing sample. This phase-retrieval tomography is particularly suited for the three-dimensional segmentation of secondary osteons (roughly cylindrical structures) which are superimposed upon an existing cortical bone structure through the process of turnover known as remodelling. The resulting images make possible the analysis of the secondary osteon structure and the relationship between an osteon and the surrounding tissue. Our observations have revealed many different and complex 3D structures of osteons that could not be studied using previous methods. This work was carried out using a laboratory-based x-ray source, which makes obtaining these sorts of images readily accessible.


Assuntos
Ósteon/citologia , Imageamento Tridimensional/métodos , Tomografia/métodos , Fêmur/citologia , Humanos
9.
Opt Express ; 18(23): 23727-39, 2010 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-21164716

RESUMO

Certain phase retrieval methods use knowledge about the free space propagation of a wave to phase a paraxial beam passing through one or more measurement planes. This approach has been widely applied and has been shown to quantitatively retrieve the refractive index profile of a sample. The quality of the phase retrieval will depend on a range of factors including sample feature size, propagation distance, measurement plane separation, wavelength and noise. Here we describe an optimisation study for two-plane phase retrieval using a laboratory-based X-ray source that considers all of these factors. We discuss our results in the context of a three-dimensional reconstruction of a sample refractive index profile.

10.
Ultramicroscopy ; 109(3): 280-6, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19162395

RESUMO

We report an experimental investigation of the optical transfer functions for an X-ray microscope operated in defocus phase-contrast mode. The results are compared with a theoretical model of partially coherent image formation and are found to be in excellent agreement.

11.
Opt Express ; 16(24): 19950-6, 2008 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-19030082

RESUMO

We describe a quantitative phase imaging process using an x-ray laboratory-based source with an extremely broad bandwidth spectrum. The thickness of a homogeneous object can be retrieved by using separately spectrally weighted values for the attenuation coefficient and the decrement of the real part of the refractive index. This method is valid for a wide range of object types, including objects with an absorption edge in the used energy range. The accessibility of conventional x-ray laboratory sources makes this method very useful for quantitative phase retrieval of homogeneous objects. We demonstrate the application of this method for quantitative phase retrieval imaging in tomographic measurements.

12.
Rev Sci Instrum ; 78(5): 053701, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17552819

RESUMO

We examine a direct filtered back projection approach that is suitable for the reconstruction of weakly absorbing homogeneous phase objects. Like recent similar approaches this method needs only one intensity image in each projection without the requirement for an intermediate step of phase retrieval. We tested the method using simulation and experimental results. Simulation results show good quantitative reconstruction which includes the correct refractive index value and distribution of the sample. However, experimental result still indicates the presence of artifacts.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Tomografia Óptica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...