Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Clin Biomech (Bristol, Avon) ; 102: 105889, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36774735

RESUMO

BACKGROUND: Patient-specific autonomous finite element analyses of femurs, based on clinical computed tomography scans may be used to monitor the progression of bone-related diseases. Some CT scan protocols provide lower resolution (slice thickness of 3 mm) that affects the accuracy. To investigate the impact of low-resolution scans on the CT-based finite element analyses results, identical CT raw data were reconstructed twice to generate a 1 mm ("gold standard") and a 3 mm slice thickness scans. METHODS: CT-based finite element analyses of twenty-four femurs (twelve patients) under stance and sideways fall loads were performed based on 1 and 3 mm slice thickness scans. Bone volume, load direction, and strains were extracted at different locations along the femurs and differences were evaluated. FINDINGS: Average differences in bone volume were 1.0 ± 1.5%. The largest average difference in strains in stance position was in the neck region (11.0 ± 13.4%), whereas in other regions these were much smaller. For sidewise fall loading, the average differences were at most 9.2 ± 16.0%. INTERPRETATION: Whole-body low dose CT scans (3 mm-slice thickness) are suboptimal for monitoring strain changes in patient's femurs but may allow longitudinal studies if larger than 5% in all areas and larger than 12% in the upper neck. CT-based finite element analyses with slice thickness of 3 mm may be used in clinical practice for patients with smoldering myeloma to associate changes in strains with progression to active myeloma if above ∼10%.


Assuntos
Fêmur , Tomografia Computadorizada por Raios X , Humanos , Análise de Elementos Finitos , Tomografia Computadorizada por Raios X/métodos , Acidentes por Quedas
2.
Bone Joint J ; 103-B(9): 1497-1504, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34465153

RESUMO

AIMS: Type 2 diabetes mellitus (T2DM) impairs bone strength and is a significant risk factor for hip fracture, yet currently there is no reliable tool to assess this risk. Most risk stratification methods rely on bone mineral density, which is not impaired by diabetes, rendering current tests ineffective. CT-based finite element analysis (CTFEA) calculates the mechanical response of bone to load and uses the yield strain, which is reduced in T2DM patients, to measure bone strength. The purpose of this feasibility study was to examine whether CTFEA could be used to assess the hip fracture risk for T2DM patients. METHODS: A retrospective cohort study was undertaken using autonomous CTFEA performed on existing abdominal or pelvic CT data comparing two groups of T2DM patients: a study group of 27 patients who had sustained a hip fracture within the year following the CT scan and a control group of 24 patients who did not have a hip fracture within one year. The main outcome of the CTFEA is a novel measure of hip bone strength termed the Hip Strength Score (HSS). RESULTS: The HSS was significantly lower in the study group (1.76 (SD 0.46)) than in the control group (2.31 (SD 0.74); p = 0.002). A multivariate model showed the odds of having a hip fracture were 17 times greater in patients who had an HSS ≤ 2.2. The CTFEA has a sensitivity of 89%, a specificity of 76%, and an area under the curve of 0.90. CONCLUSION: This preliminary study demonstrates the feasibility of using a CTFEA-based bone strength parameter to assess hip fracture risk in a population of T2DM patients. Cite this article: Bone Joint J 2021;103-B(9):1497-1504.


Assuntos
Diabetes Mellitus Tipo 2/complicações , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/etiologia , Tomografia Computadorizada por Raios X/métodos , Idoso , Estudos de Casos e Controles , Estudos de Viabilidade , Feminino , Análise de Elementos Finitos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA