Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artif Organs ; 48(4): 347-355, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37962102

RESUMO

BACKGROUND: Validated quantitative biomarkers for assessment of renal graft function during normothermic machine perfusion (NMP) conditions are lacking. The aim of this project was to quantify cortex microperfusion during ex vivo kidney perfusion using laser speckle contrast imaging (LSCI), and to evaluate the sensitivity of LSCI when measuring different levels of renal perfusion. Furthermore, we aimed to introduce LSCI measurements during NMP in differentially damaged kidneys. METHODS: Eleven porcine kidneys were nephrectomized and perfused ex vivo. Cortex microperfusion was simultaneously monitored using LSCI. First, a flow experiment examined the relationship between changes in delivered renal flow and corresponding changes in LSCI-derived cortex microperfusion. Second, renal cortical perfusion was reduced stepwise by introducing a microembolization model. Finally, LSCI was applied for measuring renal cortex microperfusion in kidneys exposed to minimal damage or 2 h warm ischemia (WI). RESULTS: Cortex microperfusion was calculated from the LSCI-obtained data. The flow experiment resulted in relatively minor changes in cortex microperfusion compared to the pump-induced changes in total renal flow. Based on stepwise injections of microspheres, we observed different levels of cortex microperfusion that correlated with administrated microsphere dosages (r2 = 0.95-0.99). We found no difference in LSCI measured cortex microperfusion between the kidneys exposed to minimal damage (renal cortex blood flow index, rcBFI = 2090-2600) and 2 h WI (rcBFI = 2189-2540). CONCLUSIONS: Based on this preliminary study, we demonstrated the feasibility of LSCI in quantifying cortex microperfusion during ex vivo perfusion. Furthermore, based on LSCI-measurements, cortical microperfusion was similar in kidneys exposed to minimal and 2 h WI.


Assuntos
Transplante de Rim , Imagem de Contraste de Manchas a Laser , Animais , Suínos , Velocidade do Fluxo Sanguíneo , Rim/irrigação sanguínea , Circulação Renal
2.
Biomedicines ; 10(2)2022 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-35203697

RESUMO

The aim of this study was to compare the test results from patients who, within a short timescale, have been tested for COVID-19 using both a pharyngeal swab and tracheal secretion. Data were collected from the database of AUH, from patients hospitalized between 1 March 2020 and 1 March 2021 who, due to symptoms of COVID-19, were tested by a pharyngeal swab and by tracheal secretion. We found great agreement between oropharyngeal swab and tracheal secretion RT-PCR testing for the diagnosis of COVID-19, with 98.5% of double tests being concordant and only 1.5% being discordant. This finding may advocate a single-test strategy being either an oropharyngeal swab RT-PCR testing or tracheal secretion, although this study revealed 15.9% false negative oropharyngeal swabs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...