Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bioelectron Med ; 10(1): 15, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38880906

RESUMO

BACKGROUND: Vagus nerve stimulation (VNS) is an established therapy for treating a variety of chronic diseases, such as epilepsy, depression, obesity, and for stroke rehabilitation. However, lack of precision and side-effects have hindered its efficacy and extension to new conditions. Achieving a better understanding of the relationship between VNS parameters and neural and physiological responses is therefore necessary to enable the design of personalized dosing procedures and improve precision and efficacy of VNS therapies. METHODS: We used biomarkers from recorded evoked fiber activity and short-term physiological responses (throat muscle, cardiac and respiratory activity) to understand the response to a wide range of VNS parameters in anaesthetised pigs. Using signal processing, Gaussian processes (GP) and parametric regression models we analyse the relationship between VNS parameters and neural and physiological responses. RESULTS: Firstly, we illustrate how considering multiple stimulation parameters in VNS dosing can improve the efficacy and precision of VNS therapies. Secondly, we describe the relationship between different VNS parameters and the evoked fiber activity and show how spatially selective electrodes can be used to improve fiber recruitment. Thirdly, we provide a detailed exploration of the relationship between the activations of neural fiber types and different physiological effects. Finally, based on these results, we discuss how recordings of evoked fiber activity can help design VNS dosing procedures that optimize short-term physiological effects safely and efficiently. CONCLUSION: Understanding of evoked fiber activity during VNS provide powerful biomarkers that could improve the precision, safety and efficacy of VNS therapies.

2.
J Neural Eng ; 21(2)2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38479016

RESUMO

Objective.In bioelectronic medicine, neuromodulation therapies induce neural signals to the brain or organs, modifying their function. Stimulation devices capable of triggering exogenous neural signals using electrical waveforms require a complex and multi-dimensional parameter space to control such waveforms. Determining the best combination of parameters (waveform optimization or dosing) for treating a particular patient's illness is therefore challenging. Comprehensive parameter searching for an optimal stimulation effect is often infeasible in a clinical setting due to the size of the parameter space. Restricting this space, however, may lead to suboptimal therapeutic results, reduced responder rates, and adverse effects.Approach. As an alternative to a full parameter search, we present a flexible machine learning, data acquisition, and processing framework for optimizing neural stimulation parameters, requiring as few steps as possible using Bayesian optimization. This optimization builds a model of the neural and physiological responses to stimulations, enabling it to optimize stimulation parameters and provide estimates of the accuracy of the response model. The vagus nerve (VN) innervates, among other thoracic and visceral organs, the heart, thus controlling heart rate (HR), making it an ideal candidate for demonstrating the effectiveness of our approach.Main results.The efficacy of our optimization approach was first evaluated on simulated neural responses, then applied to VN stimulation intraoperatively in porcine subjects. Optimization converged quickly on parameters achieving target HRs and optimizing neural B-fiber activations despite high intersubject variability.Significance.An optimized stimulation waveform was achieved in real time with far fewer stimulations than required by alternative optimization strategies, thus minimizing exposure to side effects. Uncertainty estimates helped avoiding stimulations outside a safe range. Our approach shows that a complex set of neural stimulation parameters can be optimized in real-time for a patient to achieve a personalized precision dosing.


Assuntos
Estimulação do Nervo Vago , Humanos , Animais , Suínos , Estimulação do Nervo Vago/métodos , Teorema de Bayes , Nervo Vago/fisiologia , Coração , Fibras Nervosas Mielinizadas
3.
Bioelectricity ; 2(4): 321-327, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34476364

RESUMO

Bioelectric medicine leverages natural signaling pathways in the nervous system to counteract organ dysfunction. This novel approach has potential to address conditions with unmet needs, including heart failure, hypertension, inflammation, arthritis, asthma, Alzheimer's disease, and diabetes. Neural therapies, which target the brain, spinal cord, or peripheral nerves, are already being applied to conditions such as epilepsy, Parkinson's, and chronic pain. While today's therapies have made exciting advancements, their open-loop design-where stimulation is administered without collecting feedback-means that results can be variable and devices do not work for everyone. Stimulation effects are sensitive to changes in neural tissue, nerve excitability, patient position, and more. Closing the loop by providing neural or non-neural biomarkers to the system can guide therapy by providing additional insights into stimulation effects and overall patient condition. Devices currently on the market use recorded biomarkers to close the loop and improve therapy. The future of bioelectric medicine is more holistically personalized. Collected data will be used for increasingly precise application of neural stimulations to achieve therapeutic effects. To achieve this future, advances are needed in device design, implanted and computational technologies, and scientific/medical interpretation of neural activity. Research and commercial devices are enabling the development of multiple levels of responsiveness to neural, physiological, and environmental changes. This includes developing suitable implanted technologies for high bandwidth brain/machine interfaces and addressing the challenge of neural or state biomarker decoding. Consistent progress is being made in these challenges toward the long-term vision of automatically and holistically personalized care for chronic health conditions.

4.
J Neurosci Methods ; 333: 108562, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31862376

RESUMO

BACKGROUND: Peripheral nerve interfacing has many applications ranging from investigation of neural signals to therapeutic intervention for varied diseases. This need has driven technological advancements in the field of electrode arrays and wireless systems for in-vivo electrophysiological experiments. Hence we present our fully implantable, programmable miniaturized wireless stimulation and recording devices. NEW METHOD: The method consists of technological advancements enabling implantable wireless recording up to 128 channels with a sampling rate of 50Khz and stimulation up to ±4 mA from 15 independent channels. The novelty of the technique consists of induction charging cages which enables freely moving small animals to undergo continuous electrophysiological and behavioral studies without any impediments. The biocompatible hermetic packaging technology for implantable capsules ensures stability for long-term chronic studies. RESULTS: Electromyographs wirelessly recorded from leg muscles of a macaque and a rat using implantable technology are presented during different behavioral task studies. The device's simultaneous stimulation and recording capabilities are reported when interfaced with the vagus and pelvic nerves. COMPARISON WITH EXISTING METHOD(S): The wireless interfacing technology has a large number of recording and stimulating channels without compromising on the signal quality due to sampling rates or stimulating current output capabilities. The induction charging technology along with transceiver and software interface allows experiments on multiple animals to be carried out simultaneously. CONCLUSIONS: This customizable technology using wireless power transmission, reduced battery size, and miniaturized electronics has paved way for a robust, fully implantable, hermetic neural interface system enabling the study of bioelectronic medical therapies.


Assuntos
Próteses e Implantes , Tecnologia sem Fio , Animais , Eletrodos , Desenho de Equipamento , Nervos Periféricos , Ratos
5.
Acta Biomater ; 56: 36-43, 2017 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-28062353

RESUMO

Bone-tendon, bone-ligament and bone-cartilage junctions are multi-tissue interfaces that connect materials that differ by two orders of magnitude in mechanical properties, via gradual variations in mineral content and matrix composition. These sites mediate load transfer between highly dissimilar materials and are consequently a primary site of injury during orthopedic failure. Given the large incidence rate and the lack of suitable surgical solutions for their regeneration or repair, characterization of their natural structure and subsequent replication through tissue engineering is important. Here, we evaluate the ability and accuracy of instrumented indentation to characterize the mechanical properties of both biological tissues and engineered scaffolds with interfaces between materials that contain significant changes in mechanical properties. In this study, finite element simulations and reference samples are developed that characterize how accurately indentation measures the modulus of a material as it varies with distance across a continuous interface between dissimilar tissues with multiple orders of magnitude difference in properties. Finite element simulations accurately predicted discrepancies between the modulus function across an interface observed by indentation and the true modulus function of the material and hence allow us to understand the limits of instrumented indentation as a technique for quantifying gradual changes in material properties. It was found that in order to accurately investigate mechanical property variations in tissues with significant modulus heterogeneity the indenter size should be less than 10 percent of the expected length scale of the modulus variations. STATEMENT OF SIGNIFICANCE: The interfaces between stiff and compliant orthopedic tissues such as bone-tendon, bone-ligament and bone-cartilage are frequent sites of failure during both acute and chronic orthopedic injury and as such their replication via tissue engineering is of importance. The characterization and understanding of these tissue interfaces on a mechanical basis is a key component of elucidating the structure-function relationships that allow them to function naturally and hence a core component of efforts to replicate them. This work uses finite element models and exeperiments to outline the ability of instrumented indentation to characterize the elastic modulus variations across tissue interfaces and provides guidelines for investigators seeking to use this method to understand any interface between dissimilar tissues.


Assuntos
Dimetilpolisiloxanos/química , Elasticidade , Níquel/química , Nylons/química , Escápula/química , Alicerces Teciduais/química , Animais
6.
Adv Exp Med Biol ; 881: 187-204, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26545751

RESUMO

The musculoskeletal system is comprised of three distinct tissue categories: structural mineralized tissues, actuating muscular soft tissues, and connective tissues. Where connective tissues - ligament, tendon and cartilage - meet with bones, a graded interface in mechanical properties occurs that allows the transmission of load without creating stress concentrations that would cause tissue damage. This interface typically occurs over less than 1 mm and contains a three order of magnitude difference in elastic stiffness, in addition to changes in cell type and growth factor concentrations among others. Like all engineered tissues, the replication of these interfaces requires the production of scaffolds that will provide chemical and mechanical cues, resulting in biologically accurate cellular differentiation. For interface tissues however, the scaffold must provide spatially graded chemical and mechanical cues over sub millimetre length scales. Naturally, this complicates the manufacture of the scaffolds and every stage of their subsequent cell seeding and growth, as each region has different optimal conditions. Given the higher degree of difficulty associated with replicating interface tissues compared to surrounding homogeneous tissues, it is likely that the development of complex musculoskeletal tissue systems will continue to be limited by the engineering of connective tissues interfaces with bone.


Assuntos
Osso e Ossos/metabolismo , Cartilagem/metabolismo , Ligamentos/metabolismo , Tendões/metabolismo , Engenharia Tecidual/métodos , Materiais Biocompatíveis/metabolismo , Osso e Ossos/química , Cartilagem/química , Diferenciação Celular , Células Cultivadas , Técnicas de Cocultura , Humanos , Ligamentos/química , Fenômenos Mecânicos , Células-Tronco Mesenquimais/citologia , Propriedades de Superfície , Tendões/química , Alicerces Teciduais
7.
J Biomed Mater Res A ; 102(4): 917-27, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24327556

RESUMO

Orthopedic tissue engineering requires biomaterials with robust mechanics as well as adequate porosity and permeability to support cell motility, proliferation, and new extracellular matrix (ECM) synthesis. While collagen-glycosaminoglycan (CG) scaffolds have been developed for a range of tissue engineering applications, they exhibit poor mechanical properties. Building on previous work in our lab that described composite CG biomaterials containing a porous scaffold core and nonporous CG membrane shell inspired by mechanically efficient core-shell composites in nature, this study explores an approach to improve cellular infiltration and metabolic health within these core-shell composites. We use indentation analyses to demonstrate that CG membranes, while less permeable than porous CG scaffolds, show similar permeability to dense materials such as small intestine submucosa (SIS). We also describe a simple method to fabricate CG membranes with organized arrays of microscale perforations. We demonstrate that perforated membranes support improved tenocyte migration into CG scaffolds, and that migration is enhanced by platelet-derived growth factor BB-mediated chemotaxis. CG core-shell composites fabricated with perforated membranes display scaffold-membrane integration with significantly improved tensile properties compared to scaffolds without membrane shells. Finally, we show that perforated membrane-scaffold composites support sustained tenocyte metabolic activity as well as improved cell infiltration and reduced expression of hypoxia-inducible factor 1α compared to composites with nonperforated membranes. These results will guide the design of improved biomaterials for tendon repair that are mechanically competent while also supporting infiltration of exogenous cells and other extrinsic mediators of wound healing.


Assuntos
Distinções e Prêmios , Materiais Biocompatíveis/farmacologia , Colágeno/farmacologia , Teste de Materiais , Sociedades Científicas , Tendões/citologia , Animais , Fenômenos Biomecânicos/efeitos dos fármacos , Bovinos , Adesão Celular/efeitos dos fármacos , Movimento Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Células Cultivadas , Colorado , Módulo de Elasticidade/efeitos dos fármacos , Glicosaminoglicanos , Cavalos , Membranas Artificiais , Microscopia Eletrônica de Varredura , Tubarões , Estresse Mecânico , Tendões/efeitos dos fármacos , Resistência à Tração/efeitos dos fármacos , Alicerces Teciduais/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...