Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Am J Respir Crit Care Med ; 183(5): 612-9, 2011 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-20851930

RESUMO

RATIONALE: Our understanding of how airway remodeling affects regional airway elastic properties is limited due to technical difficulties in quantitatively measuring dynamic, in vivo airway dimensions. Such knowledge could help elucidate mechanisms of excessive airway narrowing. OBJECTIVES: To use anatomical optical coherence tomography (aOCT) to compare central airway elastic properties in control subjects and those with obstructive lung diseases. METHODS: After bronchodilation, airway lumen area (Ai) was measured using aOCT during bronchoscopy in control subjects (n = 10) and those with asthma (n = 16), chronic obstructive pulmonary disease (COPD) (n = 9), and bronchiectasis (n = 8). Ai was measured in each of generations 0 to 5 while airway pressure was increased from -10 to 20 cm H(2)O. Airway compliance (Caw) and specific compliance (sCaw) were derived from the transpulmonary pressure (Pl) versus Ai curves. MEASUREMENTS AND MAIN RESULTS: Caw decreased progressively as airway generation increased, but sCaw did not differ appreciably across the generations. In subjects with asthma and bronchiectasis, Caw and sCaw were similar to control subjects and the Pl-Ai curves were left-shifted. No significant differences were observed between control and COPD groups. CONCLUSIONS: Proximal airway elastic properties are altered in obstructive lung diseases. Although central airway compliance does not differ from control subjects in asthma, bronchiectasis, or COPD, Ai is lower in asthma and the Pl-Ai relationship is left-shifted in both asthma and bronchiectasis, suggesting that airways are maximally distended at lower inflating pressures. Such changes reflect alteration in the balance between airway wall distensibility and radial traction exerted on airways by surrounding lung parenchyma favoring airway narrowing. Clinical trial registered with Australian New Zealand Clinical Trials Registry (ACTRN12607000624482).


Assuntos
Pneumopatias Obstrutivas/fisiopatologia , Tomografia de Coerência Óptica/métodos , Adolescente , Adulto , Idoso , Broncoscopia , Elasticidade , Feminino , Humanos , Pulmão/fisiopatologia , Complacência Pulmonar , Masculino , Pessoa de Meia-Idade , Adulto Jovem
2.
Respir Res ; 11: 9, 2010 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-20092657

RESUMO

BACKGROUND: Previous histological and imaging studies have shown the presence of variability in the degree of bronchoconstriction of airways sampled at different locations in the lung (i.e., heterogeneity). Heterogeneity can occur at different airway generations and at branching points in the bronchial tree. Whilst heterogeneity has been detected by previous experimental approaches, its spatial relationship either within or between airways is unknown. METHODS: In this study, distribution of airway narrowing responses across a portion of the porcine bronchial tree was determined in vitro. The portion comprised contiguous airways spanning bronchial generations (#3-11), including the associated side branches. We used a recent optical imaging technique, anatomical optical coherence tomography, to image the bronchial tree in three dimensions. Bronchoconstriction was produced by carbachol administered to either the adventitial or luminal surface of the airway. Luminal cross sectional area was measured before and at different time points after constriction to carbachol and airway narrowing calculated from the percent decrease in luminal cross sectional area. RESULTS: When administered to the adventitial surface, the degree of airway narrowing was progressively increased from proximal to distal generations (r = 0.80 to 0.98, P < 0.05 to 0.001). This 'serial heterogeneity' was also apparent when carbachol was administered via the lumen, though it was less pronounced. In contrast, airway narrowing was not different at side branches, and was uniform both in the parent and daughter airways. CONCLUSIONS: Our findings demonstrate that the bronchial tree expresses intrinsic serial heterogeneity, such that narrowing increases from proximal to distal airways, a relationship that is influenced by the route of drug administration but not by structural variations accompanying branching sites.


Assuntos
Brônquios/citologia , Brônquios/fisiologia , Broncoconstrição/fisiologia , Modelos Anatômicos , Tomografia de Coerência Óptica/métodos , Animais , Suínos
3.
J Appl Physiol (1985) ; 108(2): 401-11, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19910337

RESUMO

Regulation of airway caliber by lung volume or bronchoconstrictor stimulation is dependent on physiological, structural, and mechanical events within the airway wall, including airway smooth muscle (ASM) contraction, deformation of the mucosa and cartilage, and tensioning of elastic matrices linking wall components. Despite close association between events in the airway wall and the resulting airway caliber, these have typically been studied separately: the former primarily using histological approaches, the latter with a range of imaging modalities. We describe a new optical technique, anatomical optical coherence tomography (aOCT), which allows changes at the luminal surface (airway caliber) to be temporally related to corresponding dynamic movements within the airway wall. A fiber-optic aOCT probe was inserted into the lumen of isolated, liquid-filled porcine airways. It was used to image the response to ASM contraction induced by neural stimulation and to airway inflation and deflation. Comparisons with histology indicated that aOCT provided high-resolution images of the airway lumen including mucosal folds, the entire inner wall (mucosa and ASM), and partially the cartilaginous outer wall. Airway responses assessed by aOCT revealed several phenomena in "live" airways (i.e., not fixed) previously identified by histological investigations of fixed tissue, including a geometric relationship between ASM shortening and luminal narrowing, and sliding and bending of cartilage plates. It also provided direct evidence for distensibility of the epithelial membrane and anisotropic behavior of the airway wall. Findings suggest that aOCT can be used to relate changes in airway caliber to dynamic events in the wall of airways.


Assuntos
Músculos Respiratórios/anatomia & histologia , Músculos Respiratórios/fisiologia , Sistema Respiratório/anatomia & histologia , Parede Torácica/anatomia & histologia , Parede Torácica/fisiologia , Algoritmos , Animais , Anisotropia , Cartilagem/fisiologia , Estimulação Elétrica , Imagens de Fantasmas , Mecânica Respiratória/fisiologia , Mucosa Respiratória/fisiologia , Suínos , Fixação de Tecidos , Tomografia de Coerência Óptica
4.
J Bronchology Interv Pulmonol ; 17(4): 307-16, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23168951

RESUMO

BACKGROUND: Interventional bronchoscopists manage central airway obstruction (CAO) through dilation, tumor ablation, and/or stent insertion. Anatomical optical coherence tomography (aOCT), a validated light-based imaging technique, has the unique capacity of providing bronchoscopists with intraprocedural central airway measurements. This study aims to describe the potential role of real-time aOCT in guiding interventions during CAO procedures. METHODS: Prospective case series were recruited from patients referred for bronchoscopic management of symptomatic CAO. Preprocedure chest computed tomography (CT) scans were analyzed for relevant airway dimensions, such as stenosis caliber and length, and aided procedure planning. During bronchoscopy, an aOCT fiberoptic probe was inserted through the working channel of the bronchoscope to image the airway stenosis. From these aOCT images, stenosis dimensions were measured and compared with the preprocedure CT measurements. Preprocedure and postprocedure spirometry, Medical Research Council dyspnea score, and Eastern Cooperative Oncology Group performance status were collected to assess intervention efficacy. RESULTS: Fourteen patients were studied. CT and aOCT-based measurements of airway caliber and length correlated closely (r=0.87, P<0.001). Bland-Altman analysis showed strong agreement between measurements (mean difference 0.4±8.6 mm). The real-time nature of aOCT imaging provided the advantage of more up-to-date measurements where a delay occurred between CT and bronchoscopy or where the quality of the CT image was suboptimal. After bronchoscopy, the predicted forced expiratory flow in 1 second increased from 67±26% to 78±19% (P=0.04). Eastern Cooperative Oncology Group and dyspnea scores improved in 83% and 75% of the patients, respectively. CONCLUSIONS: aOCT provides real-time measurements of obstructing central airway lesions that can assist therapeutic interventions such as selection of endobronchial stents and airway dilatation procedures.

5.
Phys Med Biol ; 54(10): 3129-39, 2009 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-19420415

RESUMO

We present a new approach to optical coherence elastography (OCE), which probes the local elastic properties of tissue by using optical coherence tomography to measure the effect of an applied stimulus in the audio frequency range. We describe the approach, based on analysis of the Bessel frequency spectrum of the interferometric signal detected from scatterers undergoing periodic motion in response to an applied stimulus. We present quantitative results of sub-micron excitation at 820 Hz in a layered phantom and the first such measurements in human skin in vivo.


Assuntos
Estimulação Acústica/métodos , Algoritmos , Técnicas de Imagem por Elasticidade/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Pele/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Técnicas de Imagem por Elasticidade/instrumentação , Estudos de Viabilidade , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia de Coerência Óptica/instrumentação
6.
Opt Express ; 17(8): 6568-77, 2009 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-19365482

RESUMO

Anatomical optical coherence tomography (aOCT) is a long-range endoscopic imaging modality capable of quantifying size and shape of the human airway. A challenge to its in vivo application is motion artifact due to respiratory-related movement of the airway walls. This paper represents the first demonstration of respiratory gating of aOCT airway data, and introduces a novel error measure to guide appropriate parameter selection. Results indicate that at least four gates per respiratory cycle should be used, with only minor improvements as the number of gates is further increased. It is shown that respiratory gating can substantially improve the quality of aOCT images and reveal events and features that are otherwise obscured by blurring.


Assuntos
Algoritmos , Artefatos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Pulmão/anatomia & histologia , Técnicas de Imagem de Sincronização Respiratória/métodos , Tomografia de Coerência Óptica/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Chest ; 136(1): 272-276, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19225058

RESUMO

Flexible bronchoscopy is a common procedure that is used in both diagnostic and therapeutic settings but does not readily permit measurement of central airway dimensions. Anatomic optical coherence tomography (a OCT), a modification of conventional optical coherence tomography (OCT), is a novel light-based imaging tool with the capacity to measure the diameter and lumen area of the central airways accurately during bronchoscopy. This study describes the first clinical use of aOCT imaging in the lower airways in three individuals with common endobronchial pathologies. During bronchoscopy, a specialized fiberoptic probe was passed through the biopsy channel of a standard flexible bronchoscope to the site of airway pathology. Airway dimensions were measured from the generated cross-sectional images in three subjects, one with subglottic tracheal stenosis (subject 1), one with malignant left main bronchus (LMB) obstruction (subject 2), and another with severe tracheomalacia (subject 3). Measured dimensions included internal airway diameter, cross-sectional area, and, in subject 1, stenosis length. Tracheal stenosis dimensions, measured using aOCT imaging, correlated with chest CT scan findings and guided the choice of airway stent (subject 1). The airway beyond a malignant obstruction of the LMB, and beyond bronchoscopic view, could be imaged using aOCT, and the distal extent of obstructing tumor identified (subject 2). The severity of newly diagnosed tracheomalacia was able to be quantified using aOCT imaging (subject 3). aOCT imaging during bronchoscopy allows accurate real-time airway measurements and may assist bronchoscopic assessment.


Assuntos
Neoplasias Brônquicas/diagnóstico , Broncoscopia , Tomografia de Coerência Óptica , Estenose Traqueal/diagnóstico , Traqueobroncomalácia/diagnóstico , Idoso , Neoplasias Brônquicas/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estenose Traqueal/cirurgia , Traqueobroncomalácia/cirurgia
8.
Sleep ; 31(11): 1543-9, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19014074

RESUMO

STUDY OBJECTIVES: In patients with obstructive sleep apnea (OSA), the severity and frequency of respiratory events is increased in the supine body posture compared with the lateral recumbent posture. The mechanism responsible is not clear but may relate to the effect of posture on upper airway shape and size. This study compared the effect of body posture on upper airway shape and size in individuals with OSA with control subjects matched for age, BMI, and gender. PARTICIPANTS: 11 males with OSA and 11 age- and BMI-matched male control subjects. RESULTS: Anatomical optical coherence tomography was used to scan the upper airway of all subjects while awake and breathing quietly, initially when supine, and then in the lateral recumbent posture. A standard head, neck, and tongue position was maintained during scanning. Airway cross-sectional area (CSA) and anteroposterior (A-P) and lateral diameters were obtained in the oropharyngeal and velopharyngeal regions in both postures. A-P to lateral diameter ratios provided an index of regional airway shape. In equivalent postures, the ratio of A-P to lateral diameter in the velopharynx was similar in OSA and control subjects. In both groups, this ratio was significantly less for the supine than for the lateral recumbent posture. CSA was smaller in OSA subjects than in controls but was unaffected by posture. CONCLUSIONS: The upper airway changes from a more transversely oriented elliptical shape when supine to a more circular shape when in the lateral recumbent posture but without altering CSA. Increased circularity decreases propensity to tube collapse and may account for the postural dependency of OSA.


Assuntos
Faringe/anatomia & histologia , Faringe/fisiopatologia , Postura , Apneia Obstrutiva do Sono/fisiopatologia , Antropometria , Índice de Massa Corporal , Estudos Transversais , Humanos , Masculino , Pessoa de Meia-Idade , Orofaringe/anatomia & histologia , Orofaringe/fisiopatologia , Palato Mole/anatomia & histologia , Palato Mole/fisiopatologia , Polissonografia , Índice de Gravidade de Doença , Apneia Obstrutiva do Sono/diagnóstico
9.
Opt Express ; 16(22): 17521-9, 2008 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-18958032

RESUMO

Endoscopic treatment of lower airway pathologies requires accurate quantification of airway dimensions. We demonstrate the application of a real-time endoscopic optical coherence tomography system that can image lower airway anatomy and quantify airway lumen dimensions intra-operatively. Results demonstrate the ability to acquire 3D scans of airway anatomy and include comparison against a pre-operative X-ray CT. The paper also illustrates the capability of the system to assess the real-time dynamic changes within the airway that occur during respiration.


Assuntos
Imageamento Tridimensional/métodos , Sistema Respiratório/anatomia & histologia , Tomografia de Coerência Óptica/métodos , Humanos , Movimento , Radiografia Torácica , Respiração , Tomografia Computadorizada por Raios X
10.
IEEE Trans Biomed Eng ; 55(4): 1438-46, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18390336

RESUMO

In this paper, we report on anatomical optical coherence tomography, a catheter-based optical modality designed to provide quantitative sectional images of internal hollow organ anatomy over extended observational periods. We consider the design and performance of an instrument and its initial intended application in the human upper airway for the characterization of obstructive sleep apnea (OSA). Compared with current modalities, the technique uniquely combines quantitative imaging, bedside operation, and safety for use over extended periods of time with no cumulative dose limit. Our experiments show that the instrument is capable of imaging subjects during sleep, and that it can record dynamic changes in airway size and shape.


Assuntos
Imageamento Tridimensional/instrumentação , Laringoscópios , Apneia Obstrutiva do Sono/patologia , Tomografia de Coerência Óptica/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
J Sleep Res ; 17(2): 230-8, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18422508

RESUMO

This study compared shape, size and length of the pharyngeal airway in individuals with and without obstructive sleep apnoea (OSA) using a novel endoscopic imaging technique, anatomical optical coherence tomography (aOCT). The study population comprised a preliminary study group of 20 OSA patients and a subsequent controlled study group of 10 OSA patients and 10 body mass index (BMI)-, gender- and age-matched control subjects without OSA. All subjects were scanned using aOCT while awake, supine and breathing quietly. Measurements of airway cross-sectional area (CSA) and anteroposterior (A-P) and lateral diameters were obtained from the hypo-, oro- and velopharyngeal regions. A-P : lateral diameter ratios were calculated to provide an index of regional airway shape. In all subjects, pharyngeal CSA was lowest in the velopharynx. Patients with OSA had a smaller velopharyngeal CSA than controls (maximum CSA 91 +/- 40 versus 153 +/- 84 mm(2); P < 0.05) but comparable oro- (318 +/- 80 versus 279 +/- 129 mm(2); P = 0.48) and hypopharyngeal CSA (250 +/- 105 versus 303 +/- 112 mm(2); P = 0.36). In each pharyngeal region, the long axis of the airway was oriented in the lateral diameter. Airway shape was not different between the groups. Pharyngeal airway length was similar in both groups, although the OSA group had longer uvulae than the control group (16.8 +/- 6.2 versus 11.2 +/- 5.2 mm; P < 0.05). This study has shown that individuals with OSA have a smaller velopharyngeal CSA than BMI-, gender- and age-matched control volunteers, but comparable shape: a laterally oriented ellipse. These findings suggest that it is an abnormality in size rather than shape that is the more important anatomical predictor of OSA.


Assuntos
Endoscópios , Processamento de Imagem Assistida por Computador , Faringe/patologia , Faringe/fisiopatologia , Apneia Obstrutiva do Sono/fisiopatologia , Tomografia de Coerência Óptica/instrumentação , Adulto , Idoso , Resistência das Vias Respiratórias/fisiologia , Antropometria , Feminino , Humanos , Hipofaringe/patologia , Hipofaringe/fisiopatologia , Masculino , Análise por Pareamento , Pessoa de Meia-Idade , Orofaringe/patologia , Orofaringe/fisiopatologia , Ventilação Pulmonar/fisiologia , Valores de Referência , Sensibilidade e Especificidade , Apneia Obstrutiva do Sono/patologia , Insuficiência Velofaríngea/patologia , Insuficiência Velofaríngea/fisiopatologia , Vigília/fisiologia
12.
J Biomed Opt ; 13(1): 011003, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18315352

RESUMO

Three-dimensional optical coherence tomography (3D-OCT) is used to evaluate the structure and pathology of regenerating mouse skeletal muscle autografts for the first time. The death of myofibers with associated inflammation and subsequent new muscle formation in this graft model represents key features of necrosis and inflammation in the human disease Duchenne muscular dystrophy. We perform 3D-OCT imaging of excised autografts and compare OCT images with coregistered histology. The OCT images readily distinguish the necrotic and inflammatory tissue of the graft from the intact healthy muscle fibers in the underlying host tissue. These preliminary findings suggest that, with further development, 3D-OCT could be used as a tool for the evaluation of small-animal muscle morphology and pathology, in particular, for analysis of mouse models of muscular dystrophy.


Assuntos
Modelos Animais de Doenças , Rejeição de Enxerto/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Músculo Esquelético/patologia , Músculo Esquelético/transplante , Distrofias Musculares/patologia , Algoritmos , Animais , Estudos de Viabilidade , Feminino , Rejeição de Enxerto/etiologia , Aumento da Imagem/métodos , Camundongos , Camundongos Endogâmicos C57BL , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Opt Lett ; 32(4): 385-7, 2007 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-17356661

RESUMO

We present a novel needle-based device for the measurement of refractive index and scattering using low-coherence interferometry. Coupled to the sample arm of an optical coherence tomography system, the device detects the scattering response of, and optical path length through, a sample residing in a fixed-width channel. We report use of the device to make near-infrared measurements of tissues and materials with known optical properties. The device could be used to exploit the refractive index variations of tissue for medical and biological diagnostics accessible by needle insertion.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Aumento da Imagem/instrumentação , Interferometria/instrumentação , Agulhas , Refratometria/instrumentação , Tomografia de Coerência Óptica/instrumentação , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento , Interferometria/métodos , Refratometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia de Coerência Óptica/métodos
14.
Opt Lett ; 31(2): 190-2, 2006 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-16441026

RESUMO

We present theoretical calculations, based on a random phasor sum model, which show that the optical coherence tomography speckle contrast ratio is dependent on the local density of scattering particles in a sample, provided that the effective number of scatterers in the probed volume is less than about five. We confirm these theoretical predictions experimentally, using suspensions of microspheres in water. The observed contrast ratios vary in value from the Rayleigh limit of 0.52 to in excess of 2, suggesting that the contrast ratio could be useful in optical coherence tomography, particularly when imaging in ultrahigh-resolution regimes.


Assuntos
Algoritmos , Artefatos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Armazenamento e Recuperação da Informação/métodos , Modelos Estatísticos , Tomografia de Coerência Óptica/métodos , Luz , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade , Estatística como Assunto
15.
Am J Respir Crit Care Med ; 173(2): 226-33, 2006 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-16239620

RESUMO

BACKGROUND: Measurements of upper airway size and shape are important in investigating the pathophysiology of obstructive sleep apnea (OSA) and in devising, applying, and determining the effectiveness of treatment modalities. We describe an endoscopic optical technique (anatomic optical coherence tomography, aOCT) that provides quantitative real-time imaging of the internal anatomy of the human upper airway. METHODS: Validation studies were performed by comparing aOCT- and computed tomography (CT)-derived measurements of cross-sectional area (CSA) in (1) conduits in a wax phantom and (2) the velo-, oro-, and hypopharynx during wakefulness in five volunteers. aOCT scanning was performed during sleep in one subject with OSA. RESULTS: aOCT generated images of pharyngeal shape and measurements of CSA and internal dimensions that were comparable to radiographic CT images. The mean difference between aOCT- and CT-derived measurements of CSA in (1) the wax phantom was 2.1 mm(2) with limits of agreement (2 SD) from -13.2 to 17.4 mm(2) and intraclass correlation coefficient of 0.99 (p < 0.001) and (2) the pharyngeal airway was 14.1 mm(2) with limits of agreement from -43.7 to 57.8 mm(2) and intraclass correlation coefficient of 0.89 (p < 0.001). aOCT generated quantitative images of changes in upper airway size and shape before, during, and after an apneic event in an individual with OSA. CONCLUSIONS: aOCT generates quantitative, real-time measurements of upper airway size and shape with minimal invasiveness, allowing study over lengthy periods during both sleep and wakefulness. These features should make it useful for study of upper airway behavior to investigate OSA pathophysiology and aid clinical management.


Assuntos
Endoscopia/métodos , Sistema Respiratório/diagnóstico por imagem , Apneia Obstrutiva do Sono/diagnóstico , Tomografia de Coerência Óptica/instrumentação , Adulto , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Técnicas In Vitro , Masculino , Variações Dependentes do Observador , Imagens de Fantasmas , Valores de Referência , Reprodutibilidade dos Testes , Sistema Respiratório/anatomia & histologia , Apneia Obstrutiva do Sono/fisiopatologia , Tomografia de Coerência Óptica/métodos , Tomografia Computadorizada por Raios X/métodos
16.
Opt Express ; 11(15): 1817-26, 2003 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-19466064

RESUMO

We describe a long-range optical coherence tomography system for size and shape measurement of large hollow organs in the human body. The system employs a frequency-domain optical delay line of a configuration that enables the combination of high-speed operation with long scan range. We compare the achievable maximum delay of several delay line configurations, and identify the configurations with the greatest delay range. We demonstrate the use of one such long-range delay line in a catheter-based optical coherence tomography system and present profiles of the human upper airway and esophagus in vivo with a radial scan range of 26 millimeters. Such quantitative upper airway profiling should prove valuable in investigating the pathophysiology of airway collapse during sleep (obstructive sleep apnea).

17.
Opt Express ; 11(25): 3503-17, 2003 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-19471485

RESUMO

We demonstrate tomographic imaging of the refractive index of turbid media using bifocal optical coherence refractometry (BOCR). The technique, which is a variant of optical coherence tomography, is based on the measurement of the optical pathlength difference between two foci simultaneously present in a medium of interest. We describe a new method to axially shift the bifocal optical pathlength that avoids the need to physically relocate the objective lens or the sample during an axial scan, and present an experimental realization based on an adaptive liquid-crystal lens. We present experimental results, including video clips, which demonstrate refractive index tomography of a range of turbid liquid phantoms, as well as of human skin in vivo.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...