Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Endoscopy ; 55(10): 898-906, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37230471

RESUMO

BACKGROUND: This study aimed to determine long-term outcomes of gastric endoscopic submucosal dissection (ESD) in Western settings based on the latest Japanese indication criteria, and to examine predictors of outcomes and complications. METHODS: Data were collected from consecutive patients undergoing gastric ESD at four participating centers from 2009 to 2021. Retrospective analysis using logistic regression and survival analysis was performed. RESULTS: 415 patients were included (mean age 71.7 years; 56.4 % male). Absolute indication criteria (2018 guideline) were met in 75.3 % of patients. Median follow-up was 52 months. Post-resection histology was adenocarcinoma, high grade dysplasia, and low grade dysplasia in 49.9 %, 22.7 %, and 17.1 %, respectively. Perforation, early and delayed bleeding occurred in 2.4 %, 4.3 %, and 3.4 %, respectively. Rates of en bloc and R0 resection, and recurrence on first endoscopic follow-up were 94.7 %, 83.4 %, and 2.7 %, respectively. Relative indication (2018 guideline) for ESD was associated with R1 outcome (P = 0.02). Distal location (P = 0.002) and increased procedure time (P = 0.04) were associated with bleeding, and scarring (P = 0.009) and increased procedure duration (P = 0.003) were associated with perforation. Recurrence-free survival at 2 and 5 years was 94 % and 83 %, respectively. CONCLUSION: This is the largest Western multicenter cohort and suggests that gastric ESD is safe and effective in the Western setting. A quarter of patients fell outside the new absolute indications for ESD, suggesting that Western practice involves more advanced lesions. We identified the predictors of complications, which should help to inform future Western practice and research.


Assuntos
Ressecção Endoscópica de Mucosa , Neoplasias Gástricas , Humanos , Masculino , Idoso , Feminino , Resultado do Tratamento , Ressecção Endoscópica de Mucosa/efeitos adversos , Ressecção Endoscópica de Mucosa/métodos , Estudos Retrospectivos , Neoplasias Gástricas/cirurgia , Neoplasias Gástricas/patologia , Endoscopia , Mucosa Gástrica/cirurgia , Mucosa Gástrica/patologia
2.
Gastroenterology ; 163(1): 295-304.e5, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35304117

RESUMO

BACKGROUND & AIMS: Artificial intelligence (AI) may detect colorectal polyps that have been missed due to perceptual pitfalls. By reducing such miss rate, AI may increase the detection of colorectal neoplasia leading to a higher degree of colorectal cancer (CRC) prevention. METHODS: Patients undergoing CRC screening or surveillance were enrolled in 8 centers (Italy, UK, US), and randomized (1:1) to undergo 2 same-day, back-to-back colonoscopies with or without AI (deep learning computer aided diagnosis endoscopy) in 2 different arms, namely AI followed by colonoscopy without AI or vice-versa. Adenoma miss rate (AMR) was calculated as the number of histologically verified lesions detected at second colonoscopy divided by the total number of lesions detected at first and second colonoscopy. Mean number of lesions detected in the second colonoscopy and proportion of false negative subjects (no lesion at first colonoscopy and at least 1 at second) were calculated. Odds ratios (ORs) and 95% confidence intervals (CIs) were adjusted by endoscopist, age, sex, and indication for colonoscopy. Adverse events were also measured. RESULTS: A total of 230 subjects (116 AI first, 114 standard colonoscopy first) were included in the study analysis. AMR was 15.5% (38 of 246) and 32.4% (80 of 247) in the arm with AI and non-AI colonoscopy first, respectively (adjusted OR, 0.38; 95% CI, 0.23-0.62). In detail, AMR was lower for AI first for the ≤5 mm (15.9% vs 35.8%; OR, 0.34; 95% CI, 0.21-0.55) and nonpolypoid lesions (16.8% vs 45.8%; OR, 0.24; 95% CI, 0.13-0.43), and it was lower both in the proximal (18.3% vs 32.5%; OR, 0.46; 95% CI, 0.26-0.78) and distal colon (10.8% vs 32.1%; OR, 0.25; 95% CI, 0.11-0.57). Mean number of adenomas at second colonoscopy was lower in the AI-first group as compared with non-AI colonoscopy first (0.33 ± 0.63 vs 0.70 ± 0.97, P < .001). False negative rates were 6.8% (3 of 44 patients) and 29.6% (13 of 44) in the AI and non-AI first arms, respectively (OR, 0.17; 95% CI, 0.05-0.67). No difference in the rate of adverse events was found between the 2 groups. CONCLUSIONS: AI resulted in an approximately 2-fold reduction in miss rate of colorectal neoplasia, supporting AI-benefit in reducing perceptual errors for small and subtle lesions at standard colonoscopy. CLINICALTRIALS: gov, Number: NCT03954548.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Adenoma/diagnóstico por imagem , Adenoma/patologia , Inteligência Artificial , Pólipos do Colo/diagnóstico por imagem , Pólipos do Colo/patologia , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/epidemiologia , Detecção Precoce de Câncer/métodos , Humanos
3.
BMJ Case Rep ; 20172017 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-28069781

RESUMO

A 61-year-old man presented with accumulation of ascites secondary to alcoholic liver disease. He had an ascitic drain sited and 24 hours later he developed acute colonic pseudo-obstruction (ACPO). This is a rare condition previously associated with major surgery and severe sepsis. The patient did well with conservative management, and avoided the need for endoscopic decompression or surgical intervention. We believe that this is the first report of ACPO secondary to abdominal paracentesis.


Assuntos
Pseudo-Obstrução do Colo/etiologia , Paracentese/efeitos adversos , Doença Aguda , Ascite/diagnóstico por imagem , Ascite/terapia , Colo Transverso/diagnóstico por imagem , Pseudo-Obstrução do Colo/diagnóstico por imagem , Diagnóstico Diferencial , Drenagem , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...