Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
J Radiol Prot ; 37(4): 812-825, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28748829

RESUMO

AIM: The aim of this work was to assess the doses received by a diver exposed to a radiation source during maintenance work in the fuel transfer pool at a Swiss nuclear power plant, and to define whether the statutory limit was breached or not. METHOD: Onsite measurements were carried out and different scenarios were simulated using the MicroShield Software and the MCNPX Monte Carlo radiation transport code to estimate the activity of the irradiating object as well as the doses to the limbs and the effective dose delivered to the operator. RESULTS: The activity of the object was estimated to 1.8 TBq. From the various dose estimations, a conservative value of 7.5 Sv was proposed for the equivalent dose to the skin on the hands and an effective dose of 28 mSv. CONCLUSION: The use of different experimental and calculation methods allowed us to accurately estimate the activity of the object and the dose delivered to the diver, useful information for making a decision on the most appropriate scheme of follow up for the patient.


Assuntos
Centrais Nucleares , Exposição Ocupacional , Doses de Radiação , Adulto , Simulação por Computador , Humanos , Masculino , Método de Monte Carlo , Software , Suíça
2.
Radiat Prot Dosimetry ; 169(1-4): 221-4, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26541187

RESUMO

In 2013, a nationwide investigation was conducted in Switzerland to establish the population's exposure from medical X rays. A hybrid approach was used combining the Raddose database accessible on-line by the participating practices and the Swiss medical tariffication system for hospitals. This study revealed that the average annual number of examinations is 1.2 per inhabitant, and the associated annual effective dose is 1.4 mSv. It also showed that computed tomography is the most irradiating modality and that it delivers 70 % of the total dose. The annual effective dose per inhabitant registered a 17 % increase in 5 y and is comparable with what was recently reported in neighbouring countries.


Assuntos
Exposição Ambiental/análise , Monitoramento de Radiação/métodos , Radiografia/efeitos adversos , Radiografia/estatística & dados numéricos , Tomografia Computadorizada por Raios X/métodos , Bases de Dados Factuais , Humanos , Projetos Piloto , Doses de Radiação , Radiografia Intervencionista/efeitos adversos , Radiografia Intervencionista/estatística & dados numéricos , Suíça , Raios X
3.
Radiat Prot Dosimetry ; 162(3): 280-8, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24379435

RESUMO

Whole-body counting is a technique of choice for assessing the intake of gamma-emitting radionuclides. An appropriate calibration is necessary, which is done either by experimental measurement or by Monte Carlo (MC) calculation. The aim of this work was to validate a MC model for calibrating whole-body counters (WBCs) by comparing the results of computations with measurements performed on an anthropomorphic phantom and to investigate the effect of a change in phantom's position on the WBC counting sensitivity. GEANT MC code was used for the calculations, and an IGOR phantom loaded with several types of radionuclides was used for the experimental measurements. The results show a reasonable agreement between measurements and MC computation. A 1-cm error in phantom positioning changes the activity estimation by >2%. Considering that a 5-cm deviation of the positioning of the phantom may occur in a realistic counting scenario, this implies that the uncertainty of the activity measured by a WBC is ∼10-20%.


Assuntos
Modelos Biológicos , Método de Monte Carlo , Imagens de Fantasmas , Proteção Radiológica/métodos , Contagem Corporal Total/métodos , Calibragem , Simulação por Computador , Humanos , Doses de Radiação
4.
BMC Med Imaging ; 13: 22, 2013 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-23895057

RESUMO

BACKGROUND: The frequency of CT procedures has registered a significant increase over the last decade, which led at the international level to an increasing concern on the radiological risk associated with the use of CT especially in paediatrics. This work aimed at investigating the use of computed tomography in Switzerland, following the evolution of CT frequency and dose data over a decade and comparing it to data reported in other countries. METHODS: The frequency and dose data related to CT are obtained by means of a nationwide survey. National frequencies were established by projecting the collected data, using the ratio of the number of CT units belonging to the respondents to the total number of CT units in the country. The effective doses per examination were collected during an auditing campaign. RESULTS: In 2008 about 0.8 Million CT procedures (~100 CT examinations/1000 population) were performed in the country, leading to a collective effective dose of more than 6000 man.Sv (0.8 mSv/caput). In a decade the frequency of CT examinations averaged over the population and the associated average effective dose per caput increased by a factor of 2.2 and 2.9 respectively. CONCLUSIONS: Although the contribution of CT to the total medical X-rays is 6% in terms of the frequency, it represents 68% in terms of the collective effective dose. These results are comparable to those reported in a number of countries in Europe and America with similar health level.


Assuntos
Carga Corporal (Radioterapia) , Exposição Ambiental/estatística & dados numéricos , Doses de Radiação , Radiometria/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Humanos , Medição de Risco , Suíça/epidemiologia
5.
Health Phys ; 103(3): 317-21, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22850238

RESUMO

The aim of this study was to investigate the radiation exposure of the Swiss population to interventional procedures. A nationwide survey was conducted in Switzerland. The annual effective dose per capita due to interventional procedures was found to be 0.14 mSv, corresponding to 12% of the total dose. Coronary angiography and percutaneous coronary interventions were found to be the most frequent and the most irradiating interventional procedures, accounting for 52% of the total examination frequency and 64% of the dose delivered to the population. Switzerland stands at the same level as other countries in terms of effective dose per capita due to interventional radiology.


Assuntos
Exposição Ambiental/estatística & dados numéricos , Radiografia Intervencionista/efeitos adversos , Coleta de Dados , Humanos , Internacionalidade , Especificidade de Órgãos , Doses de Radiação , Suíça
6.
Health Phys ; 102(3): 263-70, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22420018

RESUMO

Nationwide surveys on radiation dose to the population from medical radiology are recommended in order to follow the trends in population exposure and ensure radiation protection.The last survey in Switzerland was conducted in 1998,and the annual effective dose from medical radiology was estimated to be 1 mSv y j(-1) per capita. The purpose of this work was to follow the trends in diagnostic radiology between 1998 and 2008 in Switzerland and determine the contribution of different modalities and types of examinations to the collective effective dose from medical x-rays. For this reason, an online database(www.raddose.ch) was developed. All healthcare providers who hold a license to run an x-ray unit in the country were invited to participate in the survey. More than 225 examinations, covering eight radiological modalities, were included in the survey. The average effective dose for each examination was reassessed. Data from about 3,500 users were collected (42% response rate). The survey showed that the annual effective dose was 1.2 mSv/capita in 2008. The most frequent examinations are conventional and dental radiographies (88%). The contribution of computed tomography was only 6% in terms of examination frequency but 68% in terms of effective dose. The comparison with other countries showed that the effective dose per capita in Switzerland was in the same range as in other countries with similar healthcare systems, although the annual number of examinations performed in Switzerland was higher.


Assuntos
Radiografia/tendências , Coleta de Dados , Feminino , Fluoroscopia/efeitos adversos , Fluoroscopia/estatística & dados numéricos , Fluoroscopia/tendências , Física Médica , Humanos , Masculino , Doses de Radiação , Proteção Radiológica , Radiografia/efeitos adversos , Radiografia/estatística & dados numéricos , Radiografia Dentária/efeitos adversos , Radiografia Dentária/estatística & dados numéricos , Radiografia Dentária/tendências , Radiografia Intervencionista/efeitos adversos , Radiografia Intervencionista/estatística & dados numéricos , Radiografia Intervencionista/tendências , Radiometria , Suíça , Tomografia Computadorizada por Raios X/efeitos adversos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Tomografia Computadorizada por Raios X/tendências
7.
Radiographics ; 28(7): 1807-16, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18772273

RESUMO

The steady increase in the number of radiologic procedures being performed is undeniably having a beneficial impact on healthcare. However, it is also becoming common practice to quantify the health detriment from radiation exposure by calculating the number of cancer-related deaths inferred from the effective dose delivered to a given patient population. The inference of a certain number of expected deaths from the effective dose is to be discouraged, but it remains important as a means of raising professional awareness of the danger associated with ionizing radiation. The risk associated with a radiologic examination appears to be rather low compared with the natural risk. However, any added risk, no matter how small, is unacceptable if it does not benefit the patient. The concept of diagnostic reference levels should be used to reduce variations in practice among institutions and to promote optimal dose indicator ranges for specific imaging protocols. In general, the basic principles of radiation protection (eg, justification and optimization of a procedure) need to be respected to help counteract the unjustified explosion in the number of procedures being performed.


Assuntos
Educação de Pacientes como Assunto/métodos , Relações Médico-Paciente , Lesões por Radiação/prevenção & controle , Proteção Radiológica/métodos , Medição de Risco/métodos , Revelação da Verdade , Fatores de Risco , Estados Unidos
8.
Rev Med Suisse ; 4(159): 1325-6, 1328-1331, 2008 May 28.
Artigo em Francês | MEDLINE | ID: mdl-18592724

RESUMO

The volume of diagnostic or therapeutic procedures in cardiology requiring the use of ionizing radiation is continuously increasing. While most examinations involve doses relatively low and thus add a low risk to the process itself, there are situations where the doses exceed the dose where excess risk of death from cancer has been statistically demonstrated. In addition, some complex procedures can result in the emergence of deterministic effects such as burns to the skin. The aim of this contribution is to provide general practitioners with the tools required to exercise the justification of the procedure with regard to the radiation hazard involved. This information may also be useful in the framework of the informed consent of the patient.


Assuntos
Doenças Cardiovasculares/diagnóstico , Doses de Radiação , Humanos , Radiação Ionizante , Medição de Risco
9.
Eur Radiol ; 18(9): 1980-6, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18389242

RESUMO

This work aimed at assessing the doses delivered in Switzerland to paediatric patients during computed tomography (CT) examinations of the brain, chest and abdomen, and at establishing diagnostic reference levels (DRLs) for various age groups. Forms were sent to the ten centres performing CT on children, addressing the demographics, the indication and the scanning parameters: number of series, kilovoltage, tube current, rotation time, reconstruction slice thickness and pitch, volume CT dose index (CTDI(vol)) and dose length product (DLP). Per age group, the proposed DRLs for brain, chest and abdomen are, respectively, in terms of CTDI(vol): 20, 30, 40, 60 mGy; 5, 8, 10, 12 mGy; 7, 9, 13, 16 mGy; and in terms of DLP: 270, 420, 560, 1,000 mGy cm; 110, 200, 220, 460 mGy cm; 130, 300, 380, 500 mGy cm. An optimisation process should be initiated to reduce the spread in dose recorded in this study. A major element of this process should be the use of DRLs.


Assuntos
Carga Corporal (Radioterapia) , Doses de Radiação , Radiometria/estatística & dados numéricos , Medição de Risco/métodos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Proteção Radiológica/métodos , Fatores de Risco , Suíça/epidemiologia
10.
Curr Probl Diagn Radiol ; 36(4): 176-84, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17601537

RESUMO

The purpose of this article was to review the strategies to control patient dose in adult and pediatric computed tomography (CT), taking into account the change of technology from single-detector row CT to multi-detector row CT. First the relationships between computed tomography dose index, dose length product, and effective dose in adult and pediatric CT are revised, along with the diagnostic reference level concept. Then the effect of image noise as a function of volume computed tomography dose index, reconstructed slice thickness, and the size of the patient are described. Finally, the potential of tube current modulation CT is discussed.


Assuntos
Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/normas , Humanos , Doses de Radiação , Medição de Risco , Fatores de Risco
11.
Eur Radiol ; 16(12): 2866-74, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16941088

RESUMO

The purpose was to compare the image quality and patient dose between 4- and 16-row MDCT units and to evaluate the dispersion of the dose delivered for common clinical examinations. Four 4- and 16-row MDCT units were used in the study. Image noise levels from images of a CatPhan phantom were compared for all units using a given CTDI(vol) of 15.0+/-1.0 mGy. Standard acquisition protocols from ten centres, shifted from 4- to 16-row MDCT (plus one additional centre for 16-row MDCT), were compared for cerebral angiography and standard chest and abdomen examinations. In addition, the protocols used with 16-row MDCT units for diagnosis of the unstable shoulder and for cardiac examinations were also compared. The introduction of 16-MSCT units did not reduce the performance of the detectors. Concerning the acquisition protocols, a wide range in practice was observed for standard examinations; DLP varied from 800 to 5,120 mGy x cm, 130 to 860 mGy x cm, 410 to 1,790 mGy x cm and 850 to 2,500 mGy x cm for cerebral angiography, standard chest, standard abdomen and heart examinations, respectively. The introduction of 16-row MDCT did not, on average, increase the patient dose for standard chest and abdominal examinations. However, a significant dose increase has been observed for cerebral angiography. There is a wide dispersion in the doses delivered, especially for cardiac imaging.


Assuntos
Doses de Radiação , Tomografia Computadorizada Espiral/métodos , Angiografia Cerebral , Humanos , Imagens de Fantasmas , Controle de Qualidade , Radiometria/métodos , Luxação do Ombro/diagnóstico por imagem , Tomografia Computadorizada Espiral/normas
12.
Swiss Med Wkly ; 134(29-30): 419-22, 2004 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-15389352

RESUMO

PRINCIPLES: Plain lumbar spine radiographic examination (LSRE) is frequently used in medical practice and delivers a high dose of ionising radiation. The objectives of the study were to determine the annual frequency of LSRE in Switzerland and its distribution according to practitioners' and patients' characteristics, as well as the related population dose of ionising radiation. METHODS: Data were extrapolated from a nationwide questionnaire survey on radiation exposure resulting from medical imaging in 1998, involving physicians and other healthcare providers performing radiological examinations in Switzerland. RESULTS: An estimated number of 273,000 LSRE are performed annually in Switzerland (39 LSRE per 1000 inhabitants per year). The collective dose to the population due to LSRE was 1130 Sv (0.16 mSv per person per year). 50-60% of these procedures were performed to confirm or rule out a diagnosis, the majority (85%) in the context of an illness. CONCLUSIONS: LSRE is the third most frequent radiographic procedure performed and delivers the highest population dose of ionising radiation of any radiodiagnostic procedure. Efforts to reduce the frequency and the radiation dose of this procedure must be kept up, technically by optimising the equipment and radioprotection measures, and clinically by implementing evidence-based approaches to appropriate indications for this imaging technique.


Assuntos
Dor Lombar/diagnóstico por imagem , Vértebras Lombares/diagnóstico por imagem , Padrões de Prática Médica/estatística & dados numéricos , Feminino , Pesquisas sobre Atenção à Saúde , Humanos , Dor Lombar/epidemiologia , Vértebras Lombares/patologia , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Radiografia/estatística & dados numéricos , Inquéritos e Questionários , Suíça/epidemiologia , Revisão da Utilização de Recursos de Saúde
13.
Z Med Phys ; 14(4): 213-21, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15656103

RESUMO

One forward-planning method and five inverse-planning methods for optimisation of treatment in radiation therapy were compared in the particular case of radiosurgery with micro-multi-leaves collimator (MMLC) and arc therapy. The "manual" method, two matrix methods (singular value decomposition and non-negative least square fit), two gradient methods (quasi-Newton and conjugate gradient algorithms) and the "simulated annealing" stochastic method were investigated. The performance of these methods was assessed in terms of the speed of convergence to an optimum, the ability to account for the organs at risk, and probability of targeted success. The study employed an adapted version of the GRATIS treatment planning system. A group of 22 patients previously treated by arc therapy for arteriovenous malformations (AVMs) were studied to evaluate the performance of the various optimisation methods for MMLC and arc therapy. The conjugate gradient method proved to be the most appropriate for most cases.


Assuntos
Radiocirurgia/métodos , Algoritmos , Simulação por Computador , Humanos , Matemática , Modelos Teóricos , Técnicas Estereotáxicas
14.
Z Med Phys ; 14(4): 222-9, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15656104

RESUMO

Two stereotactic surgery methods, arc and micro-multileave collimator (MMLC) therapy, were compared in the particular case of arteriovenous malformations (AVMs) treatment. Different methods of the treatment optimisation were used. The comparison covered a group of 22 patients suffering from peripheral and central AVMs of different sizes who underwent initially arc therapy. Several parameters were evaluated to compare the two methods: 2D and 3D isodose representations, dose-volume histograms (DVHs) and probability of success. The 3D isodoses were compared for the 22 patients showing a better conformity for the MMLC (three cases are presented). The DVHs of the AVM were also in favour of MMLC. In terms of probability of success, the results showed that are therapy was superior only in the case of small spherical lesions. MMLC therapy proved to be superior to arc therapy in all cases but central spherical small volume AVMs.


Assuntos
Malformações Arteriovenosas/cirurgia , Neoplasias/cirurgia , Radiocirurgia/métodos , Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Probabilidade , Radiocirurgia/tendências , Terapia Assistida por Computador
15.
J Manipulative Physiol Ther ; 26(1): 9-16, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12532133

RESUMO

OBJECTIVE: In this article, we investigate the use of diagnostic radiology by chiropractors in Switzerland, with the aim of determining their contribution to the annual radiation collective dose. METHODS: We approached 138 chiropractors possessing radiologic equipment and asked them to provide, among other information, the frequency of radiographic examinations. The dose associated with each type of radiographic examination was established separately. The collective dose was determined by convolution of frequency and dosimetric information. RESULTS: The number of chiropractic radiographic examinations performed in Switzerland in 1998 was 60,000, mainly spinal and pelvic examinations. The associated annual collective dose was found to be 144 Sv (an annual effective dose of 20 microSv per capita). The chiropractic contribution to the total dose due to conventional radiography in Switzerland is about 6%. CONCLUSIONS: Considering the number of chiropractors in Switzerland (less than 200), their contribution to the collective dose is relatively high. This is due to the high effective dose associated with the main types of examinations performed (eg, lumbar spine). It is therefore necessary to develop and apply guidelines for the use of this type of radiographic examination, as well as quality control programs, in order to optimize the radiographic technique and hence reduce the doses.


Assuntos
Quiroprática/estatística & dados numéricos , Padrões de Prática Médica , Radiografia/estatística & dados numéricos , Humanos , Doses de Radiação , Estações do Ano , Inquéritos e Questionários , Suíça
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...