Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Dig Dis Sci ; 63(10): 2573-2581, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29524115

RESUMO

BACKGROUND AND AIMS: Accurate optical diagnosis of diminutive polyps would allow implementing a resect and discard strategy. We evaluated the learning curve of a single training session followed by self-education in subjects with no endoscopic experience. METHODS: Learning curves were evaluated in 38 subjects employing learning curve-cumulative summation (LC-CUSUM) tests, with each participant attending one training session regarding narrow band imaging and optical diagnosis and then individually assessing 100 lesions, receiving feedback after each diagnosis. Diagnostic accuracy was subsequently evaluated in 180 patients with lesions ≤ 7 mm. Evaluators predicted each polyp's histology and recommended a surveillance interval. Determinants of accuracy were explored using regression analysis. RESULTS: According to the LC-CUSUM curve, 20 evaluators (52.6%) reached diagnostic competence after 57 lesions (IQR 55-76.5). During the diagnostic performance assessment, 11,666 diagnoses and 6840 follow-up recommendations were generated. Considering high confidence diagnoses, accuracy was 81.3% (80.5-82.1%), negative predictive value (NPV) for rectosigmoid adenomas 78.6% (76.4-80.6%), and sensitivity for adenomas 86.6% (85.8-87.4%). Two (5.3%) evaluators reached a ≥ 90% accuracy, 3 (7.9%) presented a NPV for rectosigmoid adenomas ≥ 90%, and 18 (47.4%) a sensitivity for adenomas ≥ 90%. Multivariable logistic regression showed high confidence and size ≥ 5 mm as the strongest predictors of accuracy. Fifteen (39.5%) evaluators recommended a correct or reduced follow-up interval in over 90% of subjects. CONCLUSIONS: Self-formation after a single training session did not allow most evaluators to reach the required accuracy. LC-CUSUM tests did not identify competent evaluators. Despite these results, 86.7% of follow-up intervals would have been corrected or reduced.


Assuntos
Adenoma , Pólipos do Colo , Colonoscopia , Neoplasias Colorretais , Adenoma/diagnóstico , Adenoma/patologia , Adulto , Competência Clínica , Pólipos do Colo/diagnóstico , Pólipos do Colo/patologia , Colonoscopia/educação , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/patologia , Precisão da Medição Dimensional , Feminino , Humanos , Curva de Aprendizado , Masculino , Vigilância da População , Valor Preditivo dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...