Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Doc Ophthalmol ; 148(1): 3-14, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38238632

RESUMO

The full-field stimulus test (FST) is a psychophysical technique designed for the measurement of visual function in low vision. The method involves the use of a ganzfeld stimulator, as used in routine full-field electroretinography, to deliver full-field flashes of light. This guideline was developed jointly by the International Society for Clinical Electrophysiology of Vision (ISCEV) and Imaging and Perimetry Society (IPS) in order to provide technical information, promote consistency of testing and reporting, and encourage convergence of methods for FST. It is intended to aid practitioners and guide the formulation of FST protocols, with a view to future standardisation.


Assuntos
Eletrorretinografia , Testes de Campo Visual , Eletrorretinografia/métodos , Sociedades Médicas , Estimulação Luminosa/métodos , Visão Ocular
2.
Eye (Lond) ; 26(12): 1554-62, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23079756

RESUMO

PURPOSE: To examine the rates of retinal nerve fibre layer thickness (RNFLT) change in glaucoma patients and healthy, age-similar control subjects with three techniques: scanning laser polarimetry with variable corneal compensation (VCC) and enhanced corneal compensation (ECC), and time-domain optical coherence tomography (OCT). METHODS: Sixty-one patients and thirty-three controls were examined with each technique and with standard automated perimetry (SAP) every 6 months. Rates of global RNFLT change and SAP mean deviation (MD) change were estimated with linear mixed-effects models. RESULTS: The median (interquartile range) baseline age was 64.4 (58.2, 71.0) years for patients and 62.4 (56.3, 70.1) years for controls (P=0.56). There was a median of seven examinations over 3.1 years for patients and six examinations in 3.0 years for controls. Baseline visual field MD and RNFLT for all imaging modalities were significantly lower (P<0.01) in patients compared with controls. Rates of RNFLT change were not significantly different between patients and controls (P≥0.19). Mean rates of VCC-measured RNFLT change were -0.18 and -0.37 µm per year in patients and controls, whereas the respective figures for ECC and OCT were -0.13 and -0.31 µm per year, and 0.04 and 0.61 µm per year. Mean rates of MD change were -0.20 and 0.03 dB per year in patients and controls, respectively (P=0.01). CONCLUSION: Rates of RNFLT change in glaucoma patients were not statistically different from control subjects for any modality. A significantly negative rate of MD change in patients suggests a genuine, continued deterioration in these patients not reflected by RNFLT changes.


Assuntos
Glaucoma de Ângulo Aberto/patologia , Pressão Intraocular , Fibras Nervosas/patologia , Células Ganglionares da Retina/patologia , Campos Visuais , Idoso , Feminino , Seguimentos , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Disco Óptico/patologia , Estudos Prospectivos , Reprodutibilidade dos Testes , Polarimetria de Varredura a Laser , Índice de Gravidade de Doença , Tomografia de Coerência Óptica/métodos , Testes de Campo Visual
3.
Br J Ophthalmol ; 89(8): 1008-12, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16024855

RESUMO

AIMS: To determine whether central corneal thickness (CCT) is a significant predictor of visual field and optic disc progression in open angle glaucoma. METHODS: Data were obtained from a prospective study of glaucoma patients tested with static automated perimetry and confocal scanning laser tomography every 6 months. Progression was determined using a trend based approach called evidence of change (EOC) analysis in which sectoral ordinal scores based on the significance of regression coefficients of visual field pattern deviation and neuroretinal rim area over time are summed. Visual field progression was also determined using the event based glaucoma change probability (GCP) analysis using both total and pattern deviation. RESULTS: The sample contained 101 eyes of 54 patients (mean (SD) age 56.5 (9.8) years) with a mean follow up of 9.2 (0.7) years and 20.7 (2.3) sets of examinations every 6 months. Lower CCT was associated with worse baseline visual fields and lower mean IOP in the follow up. In the longitudinal analysis CCT was not correlated with the EOC scores for visual field or optic disc change. In the GCP analyses, there was a tendency for groups classified as progressing to have lower CCT compared to non-progressing groups. In a multivariate analyses accounting for IOP, the opposite was found, whereby higher CCT was associated with visual field progression. None of the independent factors were predictive of optic disc progression. CONCLUSIONS: In this cohort of patients with established glaucoma, CCT was not a useful index in the risk assessment of visual field and optic disc progression.


Assuntos
Córnea/patologia , Glaucoma de Ângulo Aberto/patologia , Disco Óptico/patologia , Campos Visuais , Adulto , Idoso , Progressão da Doença , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Prospectivos , Psicofísica , Testes de Campo Visual
4.
Br J Ophthalmol ; 86(9): 1019-26, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12185131

RESUMO

AIMS: (1) To explore the relation between performance on tasks of familiar face recognition (FFR) and face expression difference discrimination (FED) with both perceived disability in face recognition and clinical measures of visual function in subjects with age related macular degeneration (AMD). (2) To quantify the gain in performance for face recognition tasks when subjects use a bioptic telescopic low vision device. METHODS: 30 subjects with AMD (age range 66-90 years; visual acuity 0.4-1.4 logMAR) were recruited for the study. Perceived (self rated) disability in face recognition was assessed by an eight item questionnaire covering a range of issues relating to face recognition. Visual functions measured were distance visual acuity (ETDRS logMAR charts), continuous text reading acuity (MNRead charts), contrast sensitivity (Pelli-Robson chart), and colour vision (large panel D-15). In the FFR task, images of famous people had to be identified. FED was assessed by a forced choice test where subjects had to decide which one of four images showed a different facial expression. These tasks were repeated with subjects using a bioptic device. RESULTS: Overall perceived disability in face recognition did not correlate with performance on either task, although a specific item on difficulty recognising familiar faces did correlate with FFR (r = 0.49, p<0.05). FFR performance was most closely related to distance acuity (r = -0.69, p<0.001), while FED performance was most closely related to continuous text reading acuity (r = -0.79, p<0.001). In multiple regression, neither contrast sensitivity nor colour vision significantly increased the explained variance. When using a bioptic telescope, FFR performance improved in 86% of subjects (median gain = 49%; p<0.001), while FED performance increased in 79% of subjects (median gain = 50%; p<0.01). CONCLUSION: Distance and reading visual acuity are closely associated with measured task performance in FFR and FED. A bioptic low vision device can offer a significant improvement in performance for face recognition tasks, and may be useful in reducing the handicap associated with this disability. There is, however, little evidence for a correlation between self rated difficulty in face recognition and measured performance for either task. Further work is needed to explore the complex relation between the perception of disability and measured performance.


Assuntos
Degeneração Macular/complicações , Óptica e Fotônica/instrumentação , Prosopagnosia/complicações , Idoso , Idoso de 80 Anos ou mais , Expressão Facial , Feminino , Humanos , Degeneração Macular/fisiopatologia , Degeneração Macular/psicologia , Masculino , Prosopagnosia/fisiopatologia , Prosopagnosia/psicologia , Autoavaliação (Psicologia) , Testes Visuais , Visão Binocular , Acuidade Visual
5.
Br J Ophthalmol ; 86(1): 39-42, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11801501

RESUMO

AIM: To investigate the safety and efficacy of the Zeiss Visulas II diode laser system in the reduction of intraocular pressure (IOP) in patients with complex glaucoma. METHODS: The authors analysed the medical records of patients who underwent trans-scleral diode laser cycloablation (TDC) at the Manchester Royal Eye Hospital during a 34 month period. 55 eyes of 53 patients with complex glaucoma were followed up for a period of 12-52 months (mean 23.1 months) after initial treatment with the Zeiss Visulas II diode laser system. RESULTS: Mean pretreatment IOP was 35.8 mm Hg (range 22-64 mm Hg). At the last examination, mean IOP was 17.3 mm Hg (range 0-40 mm Hg). After treatment, 45 eyes (82%) had an IOP between 5 and 22 mm Hg; in 46 eyes (84%) the preoperative IOP had been reduced by 30% or more. The mean number of treatment sessions was 1.7 (range 1-6). At the last follow up appointment, the mean number of glaucoma medications was reduced from 2.1 to 1.6 (p<0.05). In 10 eyes (18%), post-treatment visual acuity (VA) was worse than pretreatment VA by 2 or more lines. CONCLUSIONS: Treatment with the Zeiss Visulas II diode laser system can be safely repeated in order to achieve the target IOP. Treatment outcomes in this study were similar to those from previously published work using the Iris Medical Oculight SLx laser.


Assuntos
Glaucoma/cirurgia , Pressão Intraocular/fisiologia , Fotocoagulação a Laser/instrumentação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Seguimentos , Glaucoma/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pós-Operatórios/métodos , Cuidados Pré-Operatórios/métodos , Recidiva , Reoperação , Estudos Retrospectivos , Resultado do Tratamento , Transtornos da Visão/etiologia , Transtornos da Visão/fisiopatologia , Acuidade Visual/fisiologia
6.
Invest Ophthalmol Vis Sci ; 41(2): 417-21, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10670471

RESUMO

PURPOSE: To compare the relationship between sensitivity and response variability in the visual field of normal eyes and eyes with optic neuritis (ON), glaucoma (POAG), and ocular hypertension (OHT). METHODS: Frequency-of-seeing (FOS) data were collected from four visual field locations in one eye of 71 subjects (12 ON, 25 POAG, 11 OHT, and 23 normal), using a constant stimulus method on an Henson 4000 perimeter (Tinsley Instruments, Croydon, UK). At each location, at least 20 stimuli (subtending 0.5 degrees) were presented for 200 ms at six or more intensities above and below the estimated threshold. The mean and SD of the probit fitted cumulative Normal function were used to estimate sensitivity and response variability. Cluster regression analysis was carried out to determine whether there were differences in the sensitivity-log (variability) relationship between the four groups. RESULTS: Variability was found to increase with decreased sensitivity for all four groups. The combined data from the four groups was well represented (R2 = 0.57) by the function log(e)(SD) = A.sensitivity (dB) + B, where the constants A and B were -0.081 (SE, +/-0.005) and 3.27 (SE, +/-0.15), respectively. Including other statistically significant covariates (false-negative errors, P = 0.004) and factors (diagnosis, P = 0.005) into the model increased the proportion of explained variance to 62% (R2 = 0.62). Stimulus eccentricity (P = 0.34), patient age (P = 0.33), fixation loss rate (P = 0.10), and false-positive rate (P = 0.66) did not reach statistical significance as additional predictors of response variability. CONCLUSIONS: The relationship between response variability and sensitivity is similar for ON, POAG, OHT, and normal eyes. These results provide supporting evidence for the hypothesis that response variability is dependent on functional ganglion cell density.


Assuntos
Glaucoma de Ângulo Aberto/fisiopatologia , Hipertensão Ocular/fisiopatologia , Neurite Óptica/fisiopatologia , Campos Visuais , Contagem de Células , Análise por Conglomerados , Feminino , Humanos , Pressão Intraocular , Masculino , Células Ganglionares da Retina/patologia , Células Ganglionares da Retina/fisiologia , Sensibilidade e Especificidade , Testes de Campo Visual , Campos Visuais/fisiologia
7.
Invest Ophthalmol Vis Sci ; 40(13): 3147-51, 1999 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-10586936

RESUMO

PURPOSE: To establish whether there is significant diffuse loss of sensitivity in a population of patients with early glaucoma. METHODS: The differential light sensitivities at the 10 most sensitive locations from within the central 24 degrees of program 30-2 of the Humphrey Field Analyzer (Humphrey Instruments, San Leandro, CA) were compared in 38 pairs of age-matched subjects, one of each pair with early primary open-angle glaucoma (POAG) and the other with normal eyes. All subjects had had experience with automated perimetry and had clear media, visual acuity of 20/25 or better, and one or fewer false-positive or false-negative responses to catch trials. RESULTS: The mean difference in age between the subjects with glaucoma and normal subjects was 29 days (P = 0.44, maximum 1.42 years). The mean paired difference in pupil size was 0.16 mm (P = 0.26), and visual acuity was higher in the glaucoma-affected subjects (P = 0.044). The 10 highest sensitivity measurements in the POAG-affected subjects were found to be lower by a median of between 1.0 and 2.0 dB than those in the normal pair members (0.0001

Assuntos
Glaucoma de Ângulo Aberto/complicações , Fotofobia/complicações , Transtornos da Visão/complicações , Humanos , Pressão Intraocular , Luz , Estudos Prospectivos , Pupila , Acuidade Visual , Testes de Campo Visual , Campos Visuais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...