Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
J Vet Cardiol ; 54: 30-37, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-39004067

RESUMO

Three cats were presented for unusual collapsing episodes. Echocardiography revealed a hypertrophic cardiomyopathy (HCM) phenotype in each cat. Continuous electrocardiographic monitoring showed that the clinical signs coincided with periods of severe ST-segment elevation in each cat. The first cat was treated with amlodipine and diltiazem but did not improve and was euthanized due to poor quality of life. Postmortem examination revealed cardiac lymphoma without obstructive coronary disease. The second cat was thought to have cardiac lymphoma, based on pericardial effusion cytology, and was euthanized before starting therapy. The third cat was diagnosed with HCM and left ventricular outflow tract obstruction and was treated with atenolol and diltiazem. This treatment reduced the frequency of episodic clinical signs, but the cat subsequently developed congestive heart failure and was euthanized. This case series describes clinical signs associated with severe ST elevation in cats with an HCM phenotype, and their outcomes. Continuous electrocardiographic monitoring was necessary to detect transient ST elevation in each case.

2.
Clin Radiol ; 78(11): 839-847, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37827594

RESUMO

Post-mortem computed tomography (PMCT) imaging is gaining popularity and acceptance for use alongside forensic autopsies of children, predominantly to aid in the detection of traumatic injuries. Recent research on this topic has provided a breadth of new information regarding the appropriate usage, imaging guidance, and diagnostic accuracy for the identification of different paediatric pathologies. Additionally, advanced CT imaging techniques, such as PMCT angiography or ventilated PMCT, have been trialled, and post-mortem micro-CT is now being used in specialist centres for the assessment of subtle fractures in extracted bone specimens. Various image post-processing methods (e.g., three-dimensional printing from PMCT imaging data) are being used for the illustration of injuries in the medicolegal setting to a lay audience and provide another avenue for the future of forensic radiology research. In this review, the evidence-based principles and benefits of post-mortem imaging for forensic investigation in childhood deaths are presented, with a particular focus on PMCT and current practices. Variations in forensic imaging strategies around the world, published diagnostic accuracy rates, and expected normal post-mortem imaging findings are discussed, as well as potential future applications and research in this area.


Assuntos
Fraturas Ósseas , Humanos , Criança , Autopsia/métodos , Patologia Legal/métodos , Processamento de Imagem Assistida por Computador , Microtomografia por Raio-X
3.
J Vet Cardiol ; 46: 5-17, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36893525

RESUMO

INTRODUCTION/OBJECTIVES: Thin and hypokinetic myocardial segments (THyMS) represent adverse ventricular (LV) remodeling in human hypertrophic cardiomyopathy. We describe the echocardiographic features and outcome in cats with THyMS, and in a subpopulation, the echocardiographic phenotype before LV wall thinning was detected (pre-THyMS). ANIMALS: Eighty client-owned cats. MATERIALS AND METHODS: Retrospective multicenter study. Clinical records were searched for cats with THyMS, defined as LV segment(s) with end-diastolic wall thickness (LVWT) <3 mm and hypokinesis in the presence of ≥one LV segment(s) with LVWT >4 mm and normal wall motion. When available, echocardiograms pre-THyMS were assessed. Survival time was defined as time from first presentation with THyMS to death. RESULTS: Mean thickest LV wall segment (MaxLVWT) was 6.1 mm (95% CI 5.8-6.4 mm) and thinnest (MinLVWT) was 1.7 mm (95% CI 1.6-1.9 mm). The LV free wall was affected in 74%, apex in 13% and septum in 5%. Most cats (85%) presented with heart failure and/or arterial thromboembolism. Median circulating troponin I concentration was 1.4 ng/mL ([range 0.07-180 ng/mL]). Prior echocardiography results were available for 13/80 cats, a mean of 2.5 years pre-THyMS. In segments subsequently undergoing thinning, initial MaxLVWT measured 6.7 mm (95% CI 5.8-7.7 mm) vs. 1.9 mm (95% CI 1.5-2.4 mm) at last echocardiogram (P<0.0001). Survival data were available for 56/80 cats, median survival time after diagnosing THyMS was 153 days (95% CI 83-223 days). Cardiac histopathology in one cat revealed that THyMS was associated with severe transmural scarring. CONCLUSIONS: Cats with THyMS had advanced cardiomyopathy and a poor prognosis.


Assuntos
Cardiomiopatia Hipertrófica , Doenças do Gato , Insuficiência Cardíaca , Humanos , Gatos , Animais , Miocárdio/patologia , Cardiomiopatia Hipertrófica/veterinária , Ecocardiografia/veterinária , Estudos Retrospectivos , Insuficiência Cardíaca/veterinária
5.
Clin Radiol ; 77(4): 274-282, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35164928

RESUMO

Cinematic rendering (CR) is a novel post-processing technique similar to volume rendering (VR), which allows for a more photorealistic imaging reconstruction by using a complex light modelling algorithm, incorporating information from multiple light paths and predicted photon scattering patterns. Several recent publications relating to adult imaging have argued that CR gives a better "realism" and "expressiveness" experience over VR techniques. CR has also been shown to improve visualisation of musculoskeletal and vascular anatomy compared with conventional CT viewing, and may help non-radiologists to understand complex patient anatomy. In this review, we provide an overview of how CR could be used in paediatric musculoskeletal imaging, particularly in complex diagnoses, surgical planning, and patient consent processes. We present a direct comparison of VR and CR reconstructions across a range of congenital and acquired musculoskeletal pathologies, highlighting potential advantages and areas for further research.


Assuntos
Sistema Musculoesquelético , Adulto , Algoritmos , Criança , Humanos , Processamento de Imagem Assistida por Computador , Sistema Musculoesquelético/diagnóstico por imagem , Fótons , Tomografia Computadorizada por Raios X
7.
Clin Radiol ; 77(1): e40-e47, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34742547

RESUMO

AIM: To determine the added value of lateral limb radiographs in suspected physical abuse (SPA), particularly with regard to fracture detection and reporter confidence. METHODS AND MATERIALS: A 3-year (October 2017 to November 2020) retrospective study was conducted. Two blinded paediatric radiologists independently reviewed the appendicular radiographs for the presence of fractures, first by reviewing just the frontal projections, then both frontal and lateral radiographs. The additional yield of fractures and changes in reporting confidence scores were recorded. RESULTS: One hundred and thirty-eight skeletal surveys (29 live, 109 deceased children) were assessed, consisting of 16 appendicular fractures imaged in two projections (six wrist, five knee, five ankle). In the majority of cases (14/16) the fractures were already visible on the frontal view with only two fractures (one distal radius, one distal tibial) identified only by lateral projection on the blinded review. One fracture (distal tibia) was visible only on the frontal radiograph (not lateral view). The addition of lateral projection did not lead to overcalling of fractures in the remaining normal studies. Radiologist confidence scores showed an improvement with the addition of a lateral projection when a study was thought to be normal (p=0.001-0.003), but not when a fracture was identified (p>0.05). CONCLUSION: The addition of lateral radiographs improves reporting confidence in normal skeletal surveys, but only rarely helped to detect additional fractures given that most were visible on frontal projections. Larger multicentre studies of clinical practice are required to confirm these findings.


Assuntos
Maus-Tratos Infantis/diagnóstico , Fraturas Ósseas/diagnóstico por imagem , Radiografia/métodos , Osso e Ossos/diagnóstico por imagem , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos
9.
Radiography (Lond) ; 27 Suppl 1: S14-S19, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34274226

RESUMO

OBJECTIVES: To explain what a clinical academic career can be, what it can lead to for the individual, profession and most importantly the patient, and why these roles are so important to radiography. KEY FINDINGS: Multiple challenges to the adoption of clinical academic careers exist, including achievable measurable outcomes, visibility & senior support, and balancing different time demands. Equally the rewards are wide ranging and can advance both the individual and profession through role extension opportunities, increased career progression, patient benefits, and academic and research skills. CONCLUSION: Clinical academic careers can provide advantages for the individual, department, profession and most importantly the patient with advanced clinical practice through evidenced based research. IMPLICATIONS FOR PRACTICE: Improving clinical academic careers within Radiography will promote research participation and increase radiographic roles in patient-centred research delivery and development. Combining evidenced based research with academic skills will lead to improved patient care and better clinical outcomes.


Assuntos
Pessoal Técnico de Saúde , Recompensa , Humanos
10.
Ultrasound Obstet Gynecol ; 57(3): 449-458, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32149428

RESUMO

OBJECTIVES: To determine the diagnostic accuracy of postmortem magnetic resonance imaging (PM-MRI) and postmortem ultrasound (PM-US) for perinatal autopsy in the same patient cohort, and to determine whether PM-US can provide the same anatomical information as PM-MRI. METHODS: In this prospective, 5-year (July 2014-July 2019) single-center study, we performed 1.5-T PM-MRI and PM-US in an unselected cohort of perinatal deaths. The diagnostic accuracies of both modalities were calculated, using autopsy as the reference standard. As a secondary objective, the concordance rates between the two imaging modalities for the overall main diagnosis and for five anatomical regions (brain, spine, thorax, heart and abdomen) were calculated. RESULTS: During the study period, 136 cases underwent both PM-US and PM-MRI, of which 88 (64.7%) also underwent autopsy. There was no significant difference in the rates of concordance with autopsy between the two modalities for overall diagnosis (PM-US, 86.4% (95% CI, 77.7-92.0%) vs PM-MRI, 88.6% (95% CI, 80.3-93.7%)) or in the sensitivities and specificities for individual anatomical regions. There were more non-diagnostic PM-US than PM-MRI examinations for the brain (22.8% vs 3.7%) and heart (14.7% vs 5.1%). If an 'imaging-only' autopsy had been performed, PM-US would have achieved the same diagnosis as 1.5-T PM-MRI in 86.8% (95% CI, 80.0-91.5%) of cases, with the highest rates of agreement being for spine (99.3% (95% CI, 95.9-99.9%)) and cardiac (97.3% (95% CI, 92.4-99.1%)) findings and the lowest being for brain diagnoses (85.2% (95% CI, 76.9-90.8%)). CONCLUSION: Although there were fewer non-diagnostic cases using PM-MRI than for PM-US, the high concordance rate for overall diagnosis suggests that PM-US could be used for triaging cases when PM-MRI access is limited or unavailable. © 2020 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Autopsia/métodos , Feto/diagnóstico por imagem , Imageamento por Ressonância Magnética/estatística & dados numéricos , Morte Perinatal/etiologia , Ultrassonografia/estatística & dados numéricos , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Gravidez , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia/métodos
12.
Clin Radiol ; 75(7): 561.e25-561.e34, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32252991

RESUMO

AIM: To determine whether the presence of internal calcifications on perinatal post-mortem skeletal surveys (PMSS) are associated with certain diagnoses of fetal loss. METHODS AND MATERIALS: A 6-month retrospective, single-centre, cohort study was conducted on PMSS performed for perinatal death assessment. One reader re-reviewed all PMSS images for the presence and location of internal calcifications, and noted whether these were included within the original radiology report. Findings at autopsy were then reviewed independently by a second researcher and cause of fetal loss or main diagnosis recorded. Chi-squared tests were conducted to identify differences between those with and without internal calcifications at PMSS. RESULTS: Two hundred and thirty perinatal deaths (mean gestational age 18 weeks; average 12-35 weeks) were included in the study, of which 42 (18.3%) demonstrated intra-abdominal calcifications, and 16/42 (38.1%) were mentioned in the radiology reports. Most calcifications were found to be within the lumen of the gastrointestinal tract, and in the left upper quadrant of the abdomen. There was no statistical difference between identifiable causes for fetal loss at autopsy in cases with and without calcification at PMSS (59.5% versus 58.5% respectively, p=0.904). Nevertheless, where calcification and a cause for fetal loss were found, the aetiology was more likely to be due a fetal rather than placental issue. CONCLUSION: The presence of internal calcifications on PMSS was not associated with an increased likelihood of explainable fetal loss or particular diagnosis at autopsy.


Assuntos
Calcinose/diagnóstico por imagem , Morte Fetal , Autopsia , Calcinose/embriologia , Diagnóstico , Feminino , Morte Fetal/etiologia , Idade Gestacional , Humanos , Imageamento por Ressonância Magnética , Masculino , Radiografia , Estudos Retrospectivos , Microtomografia por Raio-X
14.
Ultrasound Obstet Gynecol ; 55(5): 667-675, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31271478

RESUMO

OBJECTIVES: To determine the feasibility and tissue yield of a perinatal incisionless ultrasound-guided biopsy procedure, the INcisionless Targeted Core Tissue (INTACT) technique, in the context of minimally invasive autopsy. METHODS: Cases of perinatal death in which the parents consented for minimally invasive autopsy underwent postmortem magnetic resonance imaging and an INTACT biopsy procedure, defined as needle biopsy of organs via the umbilical cord, performed under ultrasound guidance. In each case, three cores of tissue were obtained from seven target organs (both lungs, both kidneys, heart, spleen and liver). Biopsy success was predefined as an adequate volume of the intended target organ for pathological analysis, as judged by a pathologist blinded to the case and biopsy procedure. RESULTS: Thirty fetuses underwent organ sampling. Mean gestational age was 30 weeks (range, 18-40 weeks) and mean delivery-to-biopsy interval was 12 days (range, 6-22 days). The overall biopsy success rate was 153/201 (76.1%) samples, with the success rates in individual organs being highest for the heart and lungs (93% and 91%, respectively) and lowest for the spleen (11%). Excluding splenic samples, the biopsy success rate was 150/173 (86.7%). Histological abnormalities were found in 4/201 (2%) samples, all of which occurred in the lungs and kidneys of a fetus with pulmonary hypoplasia and multicystic kidney disease. CONCLUSIONS: Incisionless ultrasound-guided organ biopsy using the INTACT procedure is feasible, with an overall biopsy success rate of over 75%. This novel technique offers the ideal combination of an imaging-led autopsy with organ sampling for parents who decline the conventional invasive approach. © 2019 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Autopsia/métodos , Feto/diagnóstico por imagem , Biópsia Guiada por Imagem/métodos , Ultrassonografia Pré-Natal/métodos , Estudos de Viabilidade , Feminino , Feto/patologia , Idade Gestacional , Humanos , Recém-Nascido , Masculino , Morte Perinatal/etiologia , Gravidez
15.
Placenta ; 88: 36-43, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31670095

RESUMO

INTRODUCTION: There are considerable variations in villous morphology within a normal placenta. However, whether there is a reproducible spatial pattern of variation in villous vascular density is not known. Micro-CT provides three-dimensional volume imaging with spatial resolution down to the micrometre scale. In this study, we applied Micro-CT and histological analysis to investigate the degree of heterogeneity of vascularisation within the placenta. METHOD: Ten term placentas were collected at elective caesarean section, perfused with contrast agent and imaged whole with Micro-CT. Eight full depth tissue blocks were then taken from each placenta and imaged. Sections were taken for histological analysis. Data was analysed to investigate vascular fill, and vascular density in relation to location from cord insertion to placental edge at each scale. RESULTS: Whole placental imaging revealed no spatially consistent difference in villous vessel density within the main placental tissue, although there was a great degree of heterogeneity. Both block imaging and histological analysis found a large degree of heterogeneity of vascular density within placentas, but no strong correlation between villous vascular density and block location (rs = 0.066, p = 0.7 block imaging, rs = 0.06, p = 0.6 histological analysis). DISCUSSION: This work presents a novel method for imaging the human placenta vascular tree using multiscale Micro-CT imaging. It demonstrates that there is a large degree of variation in vascular density throughout normal term human placentas. The three-dimensional data created by this technique could be used, with more advanced computer analysis, to further investigate the structure of the vascular tree.


Assuntos
Placenta/irrigação sanguínea , Microtomografia por Raio-X , Adulto , Variação Anatômica , Feminino , Humanos , Placenta/diagnóstico por imagem , Gravidez
16.
PLoS One ; 14(6): e0218268, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31211799

RESUMO

Bone finite element (FE) studies based on infant post-mortem computed tomography (CT) examinations are being developed to provide quantitative information to assist the differentiation between accidental and inflicted injury, and unsuspected underlying disease. As the growing skeleton contains non-ossified cartilaginous regions at the epiphyses, which are not well characterised on CT examinations, it is difficult to evaluate the mechanical behaviour of the developing whole bone. This study made use of paired paediatric post mortem femoral CT and magnetic resonance imaging (MRI) examinations at two different stages of development (4 and 7 months) to provide anatomical and constitutive information for both hard and soft tissues. The work aimed to evaluate the effect of epiphyseal ossification on the propensity to shaft fractures in infants. The outcomes suggest that the failure load of the femoral diaphysis in the models incorporating the non-ossified epiphysis is within the range of bone-only FE models. There may however be an effect on the metaphysis. Confirmation of these findings is required in a larger cohort of children.


Assuntos
Osso e Ossos/diagnóstico por imagem , Fêmur/diagnóstico por imagem , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Autopsia , Osso e Ossos/fisiopatologia , Diáfises/diagnóstico por imagem , Diáfises/crescimento & desenvolvimento , Diáfises/fisiopatologia , Epífises/diagnóstico por imagem , Epífises/crescimento & desenvolvimento , Epífises/fisiopatologia , Feminino , Fêmur/crescimento & desenvolvimento , Fêmur/fisiopatologia , Análise de Elementos Finitos , Humanos , Lactente , Recém-Nascido , Masculino , Modelos Biológicos , Radiografia
17.
Clin Radiol ; 74(9): 733.e11-733.e18, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31160039

RESUMO

AIM: To determine local departmental adherence to the paediatric post-mortem magnetic resonance imaging (MRI) protocols, using a customised automated computational approach. MATERIALS AND METHODS: A retrospective review of 460 whole-body post-mortem MRI examinations performed at Great Ormond Street Hospital for Children over a 5.5-year period was assessed for adherence to a full or abbreviated imaging sequence protocol. A simple computer program was developed to batch process DICOM (digital imaging and communications in medicine) files, extracting imaging sequence details, followed by natural language processing (NLP) of authorised reports to automate information extraction of diagnostic image quality. RESULTS: The program was able to extract study parameters from the entire dataset (approximately 80 GB of data) in a few hours, and retrieve information on diagnostic image quality using NLP with an overall diagnostic accuracy for data extraction of 96.7% (445/460, 95% confidence interval [CI]: 94.7-98%). The full imaging protocol was adhered to in 305/460 (66.3%) cases, and an abbreviated protocol in 140/460 (30.4%) cases. Overall, 423/460 (91.9%) of studies were of diagnostic quality. These included 298/305 (97.7%) of the full protocol, 111/140 (79.3%) of the abbreviated protocol. In only five cases were the examinations non-diagnostic for all body systems, all of whom weighed <100 g (24.7-72 g) and imaged using the abbreviated protocol. CONCLUSION: The present study demonstrated a successful application of an automated approach for data collection for audit and quality assessment purposes using paediatric post-mortem imaging as a specific example. Re-audit of these data following change implementation will be straightforward now that the automated workflow is clearly established.


Assuntos
Autopsia/métodos , Armazenamento e Recuperação da Informação , Imageamento por Ressonância Magnética , Automação , Criança , Pré-Escolar , Auditoria Clínica , Inglaterra , Feto , Humanos , Lactente , Recém-Nascido , Estudos Retrospectivos , Imagem Corporal Total , Fluxo de Trabalho
18.
Clin Radiol ; 74(7): 496-502, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31126587

RESUMO

One of the most challenging areas of radiological imaging in children is the diagnosis of physical abuse. There is a dearth of paediatric radiologists willing to act as expert witnesses, particularly in the family courts. There are a number of reasons why radiologists may not be interested or willing to put themselves forward to work as expert witnesses in this field. A group of imaging experts recently formed the "British Society of Paediatric Radiology (BSPR) Working Group on Imaging in Suspected Physical Abuse (SPA)". The group comprises radiologists and neuroradiologists with current or previous experience of providing expert witness reports to the court in cases of SPA. The group met in January 2019 to explore pragmatic solutions to the chronic inefficiencies in both medical and legal practices and the challenges that arise from working in a legal arena with different structures, goals, and assessment criteria. Key issues concerned organisational inefficiencies, variable support from National Health Service Trusts and the Royal College of Radiologists to conduct this work, and the risk/benefit of involvement. This work is important for the patient, parents, and society in general, and highly rewarding for clinical practitioners who are involved, but there are several issues with current practices that discourage active participation. With several members of the group either retired or close to retirement, the shortage of experts is becoming a pressing issue within the UK, which requires an engaged multidisciplinary group to come up with creative solutions. Here, the group provide a consensus opinion highlighting the current barriers and potential facilitators to increasing the number of radiologists willing to provide opinions to the court.


Assuntos
Maus-Tratos Infantis/legislação & jurisprudência , Prova Pericial/legislação & jurisprudência , Mão de Obra em Saúde , Pediatria/legislação & jurisprudência , Radiologistas/legislação & jurisprudência , Criança , Humanos , Sociedades Médicas , Reino Unido
19.
Ultrasound Obstet Gynecol ; 54(6): 791-799, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30644623

RESUMO

OBJECTIVE: To compare the diagnostic rate and accuracy of 3-Tesla (T) postmortem magnetic resonance imaging (PM-MRI) and postmortem ultrasound (PM-US) in an unselected fetal population. METHODS: We performed prospectively, in a blinded manner, 3-T PM-MRI and PM-US on 160 unselected fetuses at 13-41 weeks of gestation. All imaging was reported according to a prespecified template, for five anatomical regions: brain, thorax, heart, abdomen and spine. The rates of non-diagnostic results for PM-US and PM-MRI were compared and, for results that were diagnostic, we calculated sensitivity, specificity and concordance rates for each anatomical region, using conventional autopsy as the reference standard. RESULTS: 3-T PM-MRI performed significantly better than did PM-US overall and in particular for fetuses ≥ 20 weeks' gestation. Specifically, the non-diagnostic rates for PM-MRI vs PM-US were 4.4% vs 26.9% (7/160 vs 43/160; P < 0.001) for the brain, 5.2% vs 17.4% (8/155 vs 27/155; P < 0.001) for the thorax, 3.8% vs 30.6% (6/157 vs 48/157; P < 0.001) for the heart and 3.2% vs 23.6% (5/157 vs 37/157; P < 0.001) for the abdomen. For the spine, both techniques showed an equally low non-diagnostic rate. When both postmortem imaging techniques were diagnostic, they had similar accuracy, with no difference in sensitivity or specificity, and similar concordance with autopsy (PM-US, 79.5-96.5%; PM-MRI, 81.6-99.1%). CONCLUSIONS: PM-MRI performed significantly better than PM-US in this unselected population, due mainly to a lower non-diagnostic rate. PM-MRI should remain the first-line imaging investigation for perinatal autopsy, but PM-US could be considered if MRI is not available, albeit with a higher non-diagnostic rate. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Autopsia/métodos , Morte Fetal/etiologia , Feto/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ultrassonografia/métodos , Abdome/diagnóstico por imagem , Aborto Induzido/estatística & dados numéricos , Autopsia/estatística & dados numéricos , Autopsia/tendências , Bélgica/epidemiologia , Encéfalo/diagnóstico por imagem , Causas de Morte , Feminino , Feto/patologia , Idade Gestacional , Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Gravidez , Estudos Prospectivos , Sensibilidade e Especificidade , Coluna Vertebral/diagnóstico por imagem , Tórax/diagnóstico por imagem , Ultrassonografia/estatística & dados numéricos
20.
Ultrasound Obstet Gynecol ; 54(5): 661-669, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30620444

RESUMO

OBJECTIVE: Less invasive autopsy techniques in cases of fetal or infant death have good acceptability among parents, but the published sampling adequacy in needle biopsy studies is generally poor. Minimally Invasive Autopsy with Laparoscopically assisted sampling (MinImAL) has the potential to increase the diagnostic yield of less invasive autopsy by improving the quality and quantity of tissue samples obtained, whilst permitting visualization, extraction and examination of internal organs through a small incision. The aim of this study was to present the findings of our experience with the MinImAL procedure in cases of fetal, neonatal and pediatric death. METHODS: This was a retrospective analysis of 103 prospectively recruited unselected cases of fetal, neonatal or pediatric death that underwent the MinImAL procedure at a tertiary referral center over a 5-year period. Following preprocedure 1.5-T whole-body postmortem magnetic resonance imaging, MinImAL autopsy was performed. Procedure duration, sampling adequacy and cause of death were assessed. Chi-square analysis was used to compare the 'unexplained' rate of intrauterine deaths in the cohort with that in a previously published cohort of > 1000 cases of intrauterine death examined by standard autopsy. RESULTS: MinImAL autopsy was performed successfully in 97.8% (91/93) of the cases undergoing a complete procedure. There was a satisfactory rate of adequate histological sampling in most major organs; heart (100%, 91 cases), lung (100%, 91 cases), kidney (100%, 91 cases), liver (96.7%, 88 cases), spleen (94.5%, 86 cases), adrenal glands (89.0%, 81 cases), pancreas (82.4%, 75 cases) and thymus (56.0%, 51 cases). Procedure duration was similar to that of standard autopsy in a previously published cohort of intrauterine deaths. The unexplained rate in stillbirths and intrauterine fetal deaths that underwent MinImAL autopsy was not significantly different from that following standard autopsy. CONCLUSIONS: The MinImAL procedure provides good histological yield from major organs with minimal cosmetic damage and can be learned by an autopsy practitioner. The MinImAL procedure is an appropriate minimally invasive alternative for the investigation of perinatal and pediatric deaths in which consent to full autopsy is withheld, and may have applications in both high- and low/middle-income settings. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Autopsia/métodos , Laparoscopia/métodos , Adolescente , Causas de Morte , Criança , Pré-Escolar , Estudos de Viabilidade , Morte Fetal/etiologia , Humanos , Lactente , Morte do Lactente/etiologia , Recém-Nascido , Estudos Retrospectivos , Imagem Corporal Total
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...