Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Ophthalmol ; 18: 1933-1944, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38983598

RESUMO

Purpose: To assess the refractive and visual outcomes of hyperopic and astigmatic eyes implanted with a monofocal, aspheric, bitoric intraocular lens (IOL) with plate haptics following cataract surgery. Methods: The study evaluated 51 eyes implanted with the AT TORBI 709M IOL (Carl Zeiss Meditec AG, Jena, Germany) during a follow-up of 12-months. Refractive error, rotational stability, monocular uncorrected distance visual acuity (UDVA), monocular corrected distance visual acuity (CDVA), and contrast sensitivity were analyzed at 1-, 6-, and 12-months post-surgery. Results: At 12 months, the cumulative CDVA was 20/25 in 94.12% of eyes and 20/32 or better in 98.04%. The UDVA was the same as, or better than, the CDVA in 88.24% of eyes. The mean logMAR UDVA and CDVA values were 0.06 ± 0.11 and 0.00 ± 0.08, respectively. In addition, 92.16% of eyes were within ±0.50 D and 98.04% were within ±1.00 D of a spherical equivalent, and 86.27% of eyes had refractive astigmatism ≤0.50D and 100% were ≤1.00D. The mean spherical equivalent was 0.21 ± 0.31D and the mean refractive cylinder 0.34 ± 0.27D. The IOL rotation was 1.18 ± 1.35 degrees and all eyes had a rotation ≤5 degrees. The log contrast sensitivity functions were good and similar for all spatial frequencies during follow-up. Conclusion: Our results demonstrate that implantation of the AT TORBI 709M IOL in hyperopic and astigmatic eyes is effective and safe. The visual and refractive outcomes were good, showing excellent rotational stability.

2.
Eye Vis (Lond) ; 8(1): 30, 2021 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-34392836

RESUMO

BACKGROUND: The aim of this review is to summarize the optical quality results in patients following the implantation of the V4c implantable collamer lens with a central port (ICL, STAAR Surgical Inc.). MAIN TEXT: A literature search in several databases was carried out to identify those publications, both prospective, retrospective and/or comparative with other refractive surgery procedures, reporting optical outcomes of patients who were implanted with the V4c ICL model. A total of 17 clinical studies published between 2012 and 2021 were included in this review. A detailed analysis of the available data was performed including number of eyes, follow-up and preoperative spherical equivalent. Specifically, the review focused on several optical parameters including higher-order aberrations (HOAs), modulation transfer function (MTF) cut-off frequency and Strehl ratio. This review encompassed a total of 817 eyes measured using different optical devices based on Hartmann-Shack, retinal image quality measurement and ray-tracing technologies at different follow-ups. CONCLUSIONS: The outcomes found in this review lead us to conclude that the ICL V4c model provides good optical quality, by means of different metrics, when implanted.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...