Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Sci Rep ; 12(1): 14423, 2022 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-36002556

RESUMO

Tinnitus is a common symptom in cochlear implant (CI) recipients. There is no clear evidence of the influence of tinnitus on hearing-related quality of life (QoL) in this population. The aim of this study was to assess the relationship between hearing-related QoL measured by the Speech, Spatial and Qualities of Hearing scale (SSQ12) and tinnitus annoyance or perceived change in tinnitus annoyance after cochlear implantation. The study sample consisted of 2322 implanted adults across France, Germany, Ireland, Italy, the Netherlands, Sweden and the United Kingdom. Information relating to QoL measured using the SSQ12 and tinnitus annoyance and change in tinnitus annoyance, assessed using single-item questions, were collected one or more years post-implantation. The relationship between SSQ12 score and tinnitus annoyance or change in tinnitus annoyance was analysed using linear models adjusted for age and unilateral versus bilateral implants. Tukey pairwise tests were used to compare mean SSQ12 scores across levels of tinnitus annoyance and changes. Tinnitus prevalence was 33.9% post-implantation. Recipients with tinnitus had a significantly lower SSQ12 score than recipients without tinnitus. SSQ scores varied significantly with tinnitus annoyance, age and unilateral versus bilateral implants. Overall, CI recipients who experienced less bothersome tinnitus reported better hearing-related QoL. Healthcare professionals should be aware of the influence of tinnitus on CI recipients' hearing to manage patient expectations.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Zumbido , Adulto , Audição , Humanos , Qualidade de Vida , Inquéritos e Questionários , Zumbido/etiologia , Zumbido/cirurgia , Resultado do Tratamento
2.
Int J Audiol ; 60(5): 374-384, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33074733

RESUMO

OBJECTIVE: Despite the positive effect of a cochlear implant (CI) on tinnitus in many patients, tinnitus remains a problem for a significant proportion of CI users. We investigated the acceptability and effect of sound therapy (a combination of natural background sounds and one concise tinnitus counselling session) on tinnitus and speech perception in CI users who still experienced tinnitus during CI use. DESIGN AND STUDY SAMPLE: Thirty-two CI users (32-78 years) participated in phase 1: a test at the clinic to evaluate six background sounds provided by the sound processor. Eighteen out of the 32 CI users participated in phase 2: an optional take-home evaluation of 2 weeks without sound therapy, followed by 5 weeks with sound therapy, ending with an evaluation visit. RESULTS: Thirty subjects (93.8%) found at least one background sound acceptable. In phase 2, a small improvement with sound therapy was found for tinnitus loudness, annoyance, and intrusiveness. 50% of the subjects subjectively reported benefit of sound therapy. Especially the sense of control on their tinnitus was highly appreciated. No detrimental effect on speech perception was observed. CONCLUSION: The background sounds were acceptable and provided tinnitus relief in some CI users with tinnitus during CI use.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Zumbido , Humanos , Som , Zumbido/diagnóstico , Zumbido/terapia
3.
Am J Audiol ; 27(2): 184-196, 2018 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-29507954

RESUMO

PURPOSE: The field of neuromodulation is currently seeking to treat a wide range of disorders with various types of invasive devices. In recent years, several preclinical trials and case reports in humans have been published on their potential for chronic tinnitus. However, studies to obtain insight into patients' willingness to undergo these treatments are scarce. The aim of this survey study was to find out whether tinnitus patients are willing to undergo invasive neuromodulation when taking its risks, costs, and potential benefits into account. METHOD: A Visual Analog Scale (VAS, 0-10) was used to measure the outcome. Spearman's rank-order correlation coefficients were computed to determine the correlation between patient characteristics and acceptance rates. RESULTS: Around one fifth of the patients were reasonably willing to undergo invasive treatment (VAS 5-7), and around one fifth were fully willing to do so (VAS 8-10). Hearing aids, used as a control, were accepted most, followed by cochlear implantation, deep brain stimulation, and cortical stimulation. Acceptance rates were slightly higher when the chance of cure was higher. Patients with a history of attempted treatments were more eager than others to find a new treatment for tinnitus. CONCLUSIONS: A considerable proportion of patients with tinnitus would accept a variety of invasive treatments despite the associated risks or costs. When clinical neuromodulatory studies for tinnitus are to be performed, particular attention should be given to obtaining informed consent, including explaining the potential risks and providing a realistic outcome expectation.


Assuntos
Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Inquéritos e Questionários , Zumbido/terapia , Estimulação Elétrica Nervosa Transcutânea/estatística & dados numéricos , Adolescente , Adulto , Fatores Etários , Implantes Cocleares/estatística & dados numéricos , Estudos Transversais , Eletrodos Implantados/estatística & dados numéricos , Feminino , Auxiliares de Audição/estatística & dados numéricos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Países Baixos , Medição de Risco , Índice de Gravidade de Doença , Fatores Sexuais , Estatísticas não Paramétricas , Zumbido/diagnóstico , Escala Visual Analógica , Adulto Jovem
4.
Int J Audiol ; 57(6): 426-439, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29188740

RESUMO

OBJECTIVES: Previous studies show that intracochlear electrical stimulation independent of environmental sounds appears to suppress tinnitus, even long-term. In order to assess the viability of this potential treatment option it is essential to study the effects of this tinnitus specific electrical stimulation on speech perception. DESIGN: A randomised, prospective crossover design. STUDY SAMPLE: Ten patients with unilateral or asymmetric hearing loss and severe tinnitus complaints. RESULTS: The audiological effects of standard clinical CI, formal auditory training and tinnitus specific electrical stimulation were investigated. Results show that standard clinical CI in unilateral or asymmetric hearing loss is shown to be beneficial for speech perception in quiet, speech perception in noise and subjective hearing ability. Formal auditory training does not appear to improve speech perception performance. However, CI-related discomfort reduces significantly more rapidly during CI rehabilitation in subjects receiving formal auditory training. Furthermore, tinnitus specific electrical stimulation has neither positive nor negative effects on speech perception. CONCLUSIONS: In combination with the findings from previous studies on tinnitus suppression using intracochlear electrical stimulation independent of environmental sounds, the results of this study contribute to the viability of cochlear implantation based on tinnitus complaints.


Assuntos
Correção de Deficiência Auditiva/métodos , Terapia por Estimulação Elétrica/métodos , Perda Auditiva Neurossensorial/reabilitação , Perda Auditiva Unilateral/reabilitação , Zumbido/reabilitação , Adulto , Idoso , Cóclea/fisiopatologia , Implante Coclear , Implantes Cocleares , Estudos Cross-Over , Feminino , Perda Auditiva Neurossensorial/complicações , Perda Auditiva Neurossensorial/psicologia , Perda Auditiva Unilateral/complicações , Perda Auditiva Unilateral/psicologia , Humanos , Masculino , Pessoa de Meia-Idade , Ruído , Estudos Prospectivos , Percepção da Fala/fisiologia , Zumbido/etiologia , Zumbido/psicologia , Resultado do Tratamento
5.
Ear Nose Throat J ; 95(4-5): E9-E15, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27140029

RESUMO

Electrical stimulation by cochlear implant (CI) has been proven to be a viable treatment option for tinnitus in many recent studies. In addition, intracochlear electrical stimulation independent of an acoustic input appears to suppress tinnitus, at least in the short term. We conducted a case study to investigate the long-term effects of both standard CI and intracochlear electrical stimulation independent of an acoustic input on tinnitus in a patient with single-sided deafness and tinnitus. We found no negative effects of intracochlear electrical stimulation independent of an acoustic input on speech perception in noise. Furthermore, the additional use of a standard CI was advantageous for speech discrimination in our patient. We conclude that long-term tinnitus suppression can be achieved via intracochlear electrical stimulation with looped patterns. Our findings in terms of speech discrimination in our patient were consistent with those reported in previous studies.


Assuntos
Implante Coclear , Terapia por Estimulação Elétrica , Zumbido/terapia , Audiometria de Tons Puros , Implantes Cocleares , Perda Auditiva Súbita/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Percepção da Fala , Teste do Limiar de Recepção da Fala , Zumbido/complicações , Zumbido/fisiopatologia , Resultado do Tratamento
6.
PLoS One ; 11(4): e0153131, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27111333

RESUMO

INTRODUCTION: Earlier studies show that a Cochlear Implant (CI), capable of providing intracochlear electrical stimulation independent of environmental sounds, appears to suppress tinnitus at least for minutes. The current main objective is to compare the long-term suppressive effects of looped (i.e. repeated) electrical stimulation (without environmental sound perception) with the standard stimulation pattern of a CI (with environmental sound perception). This could open new possibilities for the development of a "Tinnitus Implant" (TI), an intracochlear pulse generator for the suppression of tinnitus. MATERIALS AND METHODS: Ten patients with single sided deafness suffering from unilateral tinnitus in the deaf ear are fitted with a CI (MED-EL Corporation, Innsbruck, Austria). Stimulation patterns are optimized for each individual patient, after which they are compared using a randomized crossover design, with a follow-up of six months, followed by a 3 month period using the modality of patient's choice. RESULTS: Results show that tinnitus can be suppressed with intracochlear electrical stimulation independent of environmental sounds, even long term. No significant difference in tinnitus suppression was found between the standard clinical CI and the TI. CONCLUSION: It can be concluded that coding of environmental sounds is no requirement for tinnitus suppression with intracochlear electrical stimulation. It is therefore plausible that tinnitus suppression by CI is not solely caused by an attention shift from the tinnitus to environmental sounds. Both the standard clinical CI and the experimental TI are potential treatment options for tinnitus. These findings offer perspectives for a successful clinical application of the TI, possibly even in patients with significant residual hearing. TRIAL REGISTRATION: TrialRegister.nl NTR3374.


Assuntos
Cóclea/fisiopatologia , Surdez/complicações , Estimulação Elétrica , Zumbido/prevenção & controle , Estudos Cross-Over , Surdez/fisiopatologia , Humanos , Estudos Prospectivos , Zumbido/complicações , Escala Visual Analógica
7.
Ann Otol Rhinol Laryngol ; 125(5): 378-84, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26631764

RESUMO

OBJECTIVE: To improve the estimation of the perceived pitch in a single-sided deaf cochlear implant (CI) listener by using accurate 3-dimensional (3D) image analysis of the cochlear electrode positions together with the predicted tonotopical function for humans. METHODS: An SSD CI user underwent a Cone-Beam computed tomography (CBCT) scan. Electrode contacts were marked in 3D space in relation to the nearest point on the cochlear lateral wall. Distance to the base of the lateral wall was calculated and plotted against the place-pitch function for humans. An adaptive procedure was used to elicit the perceived pitch of electrically evoked stimulation by matching it with a contralateral acoustic pitch. RESULTS: The electrically evoked pitch percept matched well with the calculated frequency. The median mismatch in octaves was 0.12 for our method in comparison to 0.69 using the conventional Stenvers view. CONCLUSION: A method of improved image analysis is described that can be used to predict the pitch percept on corresponding cochlear electrode positions. This method shows the potential of 3D imaging in CI fitting optimization.


Assuntos
Implantes Cocleares , Tomografia Computadorizada de Feixe Cônico/métodos , Perda Auditiva Neurossensorial/diagnóstico por imagem , Imageamento Tridimensional , Discriminação da Altura Tonal/fisiologia , Estimulação Acústica , Feminino , Perda Auditiva Neurossensorial/fisiopatologia , Perda Auditiva Neurossensorial/cirurgia , Humanos , Pessoa de Meia-Idade , Pessoas com Deficiência Auditiva
8.
Audiol Neurootol ; 20(5): 294-313, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26227468

RESUMO

Cochlear implantation is a viable treatment option for tinnitus, but the underlying mechanism is yet unclear. Is the tinnitus suppression due to the reversal of the assumed maladaptive neuroplasticity or is it the shift in attention from the tinnitus to environmental sounds and therefore a reduced awareness that reduces tinnitus perception? In this prospective trial, 10 patients with single-sided deafness were fitted with a cochlear implant to investigate the effect of looped intracochlear electrical stimulation (i.e. stimulation that does not encode environmental sounds) on tinnitus, in an effort to find optimal stimulation parameters. Variables under investigation were: amplitude (perceived stimulus loudness), anatomical location inside the cochlea (electrode/electrodes), amplitude modulation, polarity (cathodic/anodic first biphasic stimulation) and stimulation rate. The results suggest that tinnitus can be reduced with looped electrical stimulation, in some cases even with inaudible stimuli. The optimal stimuli for tinnitus suppression appear to be subject specific. However, medium-to-loud stimuli suppress tinnitus significantly better than soft stimuli, which partly can be explained by the masking effect. Although the long-term effects on tinnitus would still have to be investigated and will be described in part II, intracochlear electrical stimulation seems a potential treatment option for tinnitus in this population.


Assuntos
Implante Coclear , Perda Auditiva Unilateral/complicações , Zumbido/terapia , Adulto , Idoso , Implantes Cocleares , Terapia por Estimulação Elétrica , Feminino , Perda Auditiva Unilateral/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Zumbido/etiologia , Zumbido/fisiopatologia , Resultado do Tratamento
9.
Ear Hear ; 36(1): 125-35, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25090456

RESUMO

OBJECTIVES: Research on tinnitus suppression by intracochlear electrical stimulation has gained interest over the past few decades and it has become easier to apply since the introduction of cochlear implants (CI). This study attempted to gain more insight into optimal stimulation characteristics for tinnitus suppression. DESIGN: Eleven subjects with unilateral CI and tinnitus were recruited from our CI clinic. Electrical stimulation, independent of acoustic sounds, was generated using their CI. The current prospective (single blinded) experimental study systematically assessed two stimulation parameters, namely current level and the anatomical stimulation site inside the cochlea and their short-term effect on tinnitus. RESULTS: Approximately one-third of the tested conditions were successful in which case tinnitus loudness was reduced by at least 30%. At least one successful condition was achieved for nine subjects (82%). Complete suppression was achieved in 6 out of 107 tested conditions (6%). The effect of subthreshold electrical stimulation on tinnitus suppression did not differ significantly from above threshold electrical stimulation. However, a positive relation between mean percentage tinnitus suppression and current level was observed. Pitch-matched electrical stimulation did not appear to suppress tinnitus better than other tested conditions. CONCLUSIONS: The majority of the subjects were able to experience tinnitus reduction through intracochlear electrical stimulation independent of acoustic sounds. Tinnitus can be reduced with audible or even inaudible, subthreshold stimuli. Clear trends in optimal stimulation characteristics were not found. Optimal stimulus characteristics for tinnitus reduction therefore appear to be highly subject-specific.


Assuntos
Cóclea , Implantes Cocleares , Terapia por Estimulação Elétrica/métodos , Perda Auditiva Neurossensorial/cirurgia , Zumbido/terapia , Idoso , Implante Coclear , Estudos de Coortes , Feminino , Perda Auditiva Neurossensorial/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Método Simples-Cego , Zumbido/complicações
10.
Curr Opin Otolaryngol Head Neck Surg ; 20(5): 398-403, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22931903

RESUMO

PURPOSE OF REVIEW: Tinnitus is a symptom that is highly associated with hearing loss. Its incidence is expected to increase due to the detrimental effects of occupational and leisure noise. Even though no standard treatment is currently available, the effect of cochlear implants on tinnitus in single-sided deafness (SSD) is under scientific attention. This review reveals an overview of all publicly available reports about cochlear implant as a treatment for tinnitus in SSD. RECENT FINDINGS: Cochlear implantation in SSD suppresses tinnitus in most of the cases. Some studies even demonstrate complete tinnitus suppression after implantation. No tinnitus worsening is reported in any of the cases. Furthermore, tinnitus does not restore during the electrical stimulation presented by the cochlear implant. The tinnitus level seems to stabilize after 3-6 months after the first fitting. SUMMARY: Although the underlying mechanism responsible for the observed tinnitus suppression is not yet clear, cochlear implantation should be considered as a treatment option for tinnitus arising from SSD. However, appropriate patient selection is essential as it is expected that it is a requirement that tinnitus arises from cochlear deafferentation.


Assuntos
Implante Coclear/métodos , Implantes Cocleares , Perda Auditiva Unilateral/cirurgia , Zumbido/cirurgia , Surdez/diagnóstico , Surdez/cirurgia , Feminino , Seguimentos , Perda Auditiva Unilateral/diagnóstico , Humanos , Masculino , Medição de Risco , Zumbido/diagnóstico , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...