Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Opt Express ; 13(3): 1774-1783, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35414989

RESUMO

Acoustic resolution photoacoustic microscopy (AR-PAM) has gained much attention in the past two decades due to its high contrast, scalable resolution, and relatively higher imaging depth. Multimode optical fibers (MMF) are extensively used to transfer light to AR-PAM imaging scan-head from the laser source. Typically, peak-power-compensation (PPC) is used to reduce the effect of pulse-to-pulse peak-power variation in generated photoacoustic (PA) signals. In MMF, the output intensity profile fluctuates due to the coherent nature of light and mode exchange caused by variations in the bending of the fibers during scanning. Therefore, using a photodiode (PD) to capture a portion of the total power of pulses as a measure of illuminated light on the sample may not be appropriate for accurate PPC. In this study, we have investigated the accuracy of PPC in fiber-guided and free-space AR-PAM systems. Experiments were conducted in the transparent and highly scattering medium. Based on obtained results for the MMF-based system, to apply PPC to the generated PA signals, tightly focused light confocal with the acoustic focus in a transparent medium must be used. In the clear medium and highly focused illumination, enhancement of about 45% was obtained in the homogeneity of an optically homogeneous sample image. In addition, it is shown that, as an alternative, free-space propagation of the laser pulses results in more accurate PPC in both transparent and highly scattering mediums. In free-space light transmission, enhancement of 25-75% was obtained in the homogeneity of the optically homogeneous sample image.

2.
Biomed Opt Express ; 12(4): 1834-1845, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33996201

RESUMO

In recent years, photoacoustic imaging has found vast applications in biomedical imaging. Photoacoustic imaging has high optical contrast and high ultrasound resolution allowing deep tissue non-invasive imaging beyond the optical diffusion limit. Q-switched lasers are extensively used in photoacoustic imaging due to the availability of high energy and short laser pulses, which are essential for high-resolution photoacoustic imaging. In most cases, this type of light source suffers from pulse peak-power energy variations and timing jitter noise, resulting in uncertainty in the output power and arrival time of the laser pulses. These problems cause intensity degradation and temporal displacement of generated photoacoustic signals which in turn deteriorate the quality of the acquired photoacoustic images. In this study, we used a high-speed data acquisition system in combination with a fast photodetector and a software-based approach to capture laser pulses precisely in order to reduce the effect of timing jitter and normalization of the photoacoustic signals based on pulse peak-powers simultaneously. In the experiments, maximum axial accuracy enhancement of 14 µm was achieved in maximum-amplitude projected images on XZ and YZ planes with ±13.5 ns laser timing jitter. Furthermore, photoacoustic signal enhancement of 77% was obtained for 75% laser pulses peak-power stability.

3.
Sci Rep ; 10(1): 9429, 2020 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-32523058

RESUMO

Optical intrinsic signal imaging (OISi) method is an optical technique to evaluate the functional connectivity (FC) of the cortex in animals. Already, using OISi, the FC of the cortex has been measured in time or frequency domain separately, and at frequencies below 0.08 Hz, which is not in the frequency range of hemodynamic oscillations which are able to track fast cortical events, including neurogenic, myogenic, cardiac and respiratory activities. In the current work, we calculated the wavelet coherence (WC) transform of the OISi time series to evaluate the cerebral response changes in the stroke rats. Utilizing WC, we measured FC at frequencies up to 4.5 Hz, and could monitor the time and frequency dependency of the FC simultaneously. The results showed that the WC of the brain diminished significantly in ischemic motor and somatosensory cortices. According to the statistical results, the signal amplitude, responsive area size, correlation, and wavelet coherence of the motor and the somatosensory cortices for stroke hemisphere were found to be significantly lower compared to the healthy hemisphere. The obtained results confirm that the OISi-based WC analysis is an efficient method to diagnose the relative severity of infarction and the size of the infarcted region after ischemic stroke.


Assuntos
Isquemia Encefálica/fisiopatologia , Imagem Óptica/métodos , Animais , Encéfalo/fisiopatologia , Masculino , Monitorização Fisiológica/métodos , Ratos , Ratos Wistar , Córtex Somatossensorial/fisiologia , Acidente Vascular Cerebral/fisiopatologia , Análise de Ondaletas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...