Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Jpn J Radiol ; 42(2): 158-164, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37633874

RESUMO

Recently, computed tomography with photon-counting detector (PCD-CT) has been developed to enable high-resolution imaging at a lower radiation dose. PCD-CT employs a photon-counting detector that can measure the number of incident X-ray photons and their energy. The newly released PCD-CT (NAEOTOM Alpha, Siemens Healthineers, Forchheim, Germany) has been in clinical use at our institution since December 2022. The PCD-CT offers several advantages over current state-of-the-art energy-integrating detector CT (EID-CT). The PCD-CT does not require septa to create a detector channel, while EID-CT does. Therefore, downsizing the anode to achieve higher resolution does not affect the dose efficiency of the PCD-CT. CT is an indispensable modality for evaluating ear ossicles. The ear ossicles and joints are clearly depicted by PCD-CT. In particular, the anterior and posterior legs of the stapes, which are sometimes unclear on conventional CT scans, can be clearly visualized. We present cases of congenital anomalies of the ossicular chain, ossicular chain dislocation, tympanosclerosis, and cholesteatoma in which PCD-CT was useful. This short article reports the usefulness of PCD-CT in the 3D visualization of the ear ossicles.


Assuntos
Intensificação de Imagem Radiográfica , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Intensificação de Imagem Radiográfica/métodos , Fótons , Ossículos da Orelha/diagnóstico por imagem
2.
Acta Med Okayama ; 77(6): 647-650, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38145939

RESUMO

A 67-year-old man was referred to our hospital for the diagnosis and treatment of prostate cancer. Multidisciplinary discussion led to intensity-modulated radiotherapy preceded by hormone therapy. Before radiotherapy, a biodegradable hydrogel spacer (HS) was placed between the prostate and rectum to reduce radiation injury risk. Three weeks postplacement, pelvic magnetic resonance imaging revealed HS migration into the pelvic vein. Subsequent whole-body contrast-enhanced computed tomography (CECT) revealed HS migration into the pulmonary artery. The patient showed no symptoms or clinical signs. Radiotherapy was completed uneventfully. Complete absorption of the migrated HS was confirmed using CECT images 5 months postplacement.


Assuntos
Hidrogéis , Neoplasias da Próstata , Masculino , Humanos , Idoso , Hidrogel de Polietilenoglicol-Dimetacrilato , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/patologia , Próstata/patologia , Reto/patologia , Neoplasias da Próstata/patologia
3.
Abdom Radiol (NY) ; 47(6): 1929-1938, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35226124

RESUMO

PURPOSE: This study aimed to investigate the characteristics of magnetic resonance imaging (MRI) findings in pure prostatic ductal adenocarcinoma. METHODS: From January 2009 to February 2020, seven patients who were diagnosed with pure prostatic ductal adenocarcinoma and had a referable preoperative MRI scan were included in the study. We evaluated the following MRI findings for each tumor: size, location, presence of multi-cystic component, and apparent diffusion coefficient (ADC) value. RESULTS: The median maximum diameter of the tumors was 22 mm (range 19-70 mm). Regarding transverse distribution, five tumors were located in the periurethral area and two were located peripherally apart from the urethra. Two of the seven tumors had cystic components. The median ADC value of the tumors was 0.754 × 10-3 mm2/s (range 0.570-0.963 × 10-3 mm2/s). Based on the transverse distribution and components of the tumors on MRI, ductal adenocarcinomas were classified into three types: type I as a non-cystic tumor located peripherally apart from the urethra (29%, two cases); type II as a non-cystic tumor located in the periurethral area (43%, three cases); and type III as a tumor with a multi-cystic component (29%, two cases). CONCLUSION: The non-cystic mass with periurethral distribution (type II) and multi-cystic mass (type III) may be characteristic features that differentiate pure ductal adenocarcinoma from ordinary acinar adenocarcinoma on MRI.


Assuntos
Carcinoma de Células Acinares , Neoplasias da Próstata , Carcinoma de Células Acinares/patologia , Imagem de Difusão por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Neoplasias da Próstata/patologia
4.
Jpn J Radiol ; 36(4): 285-294, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29429141

RESUMO

PURPOSE: The quality of images acquired using single-energy metal artifact reduction (SEMAR) on helical lung computed tomography (CT) in patients with pulmonary arteriovenous malformation (PAVM) after coil embolization was retrospectively evaluated. MATERIALS AND METHODS: CT images were reconstructed with and without SEMAR. Twenty-seven lesions [20 patients (2 males, 18 females), mean age 61.2 ± 11.0 years; number of embolization coils, 9.8 ± 5.0] on contrast-enhanced CT and 18 lesions of non-enhanced lung CT concurrently performed were evaluated. Regions of interest were positioned around the coils and mean standard deviation value was compared as noise index. Two radiologists visually evaluated metallic coil artifacts using a four-point scale: 4 = minimal; 3 = mild; 2 = strong; 1 = extensive. RESULTS: Noise index was significantly improved with SEMAR versus without SEMAR (median [interquartile range]; 194.4 [161.6-211.9] Hounsfield units [HU] vs. 243.9 [220.4-286.0] HU; p < 0.001). Visual score was significantly improved with SEMAR versus without SEMAR (Reader 1, 3 [3] vs.1 [1]; Reader 2, 3 [3] vs.1 [1]; p < 0.001). Significant differences were similarly demonstrated on lung CT (p < 0.001). CONCLUSION: SEMAR provided clear chest CT images in patients who underwent PAVM coil embolization.


Assuntos
Malformações Arteriovenosas/terapia , Artefatos , Prótese Vascular , Embolização Terapêutica/métodos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada Espiral/métodos , Adulto , Idoso , Algoritmos , Malformações Arteriovenosas/diagnóstico por imagem , Meios de Contraste , Feminino , Humanos , Pulmão/irrigação sanguínea , Pulmão/diagnóstico por imagem , Masculino , Metais , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...