Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Curr Radiopharm ; 12(1): 29-39, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30215339

RESUMO

OBJECTIVE: The characterization of cancerous tissue and bone metastasis can be distinguished by accurate assessment of accumulated uptake and activity from different radioisotopes. The various parameters and phenomena such as calibration factor, Compton scattering, attenuation and penetration intrinsicallyinfluence calibration equation, and the qualification of images as well. METHODS: The camera calibration factor (CF) translates reconstructed count map into absolute activity map, which is determined by both planar and tomographic scans using different phantom geometries. In this study, the CF for radionuclides of Tc-99m and Sm-153 in soft tissue and bone was simulated by the Monte Carlo method, and experimental results were obtained in equivalent tissue and bone phantoms. It may be employed for the simultaneous correction of the scattering and attenuation rays interacted with the camera, leading to corrected counts. Also, the target depth (d) may be estimated by a combination of scattering and photoelectric functions, which we have published before. RESULTS: The calibrated equations for soft tissue phantom for the radionuclides were obtained by RTc = - 10d+ 300 and RSm = -8d + 100, and the relative errors between the simulated and experimental results were 4.5% and 3.1%, respectively. The equations for bone phantom were RTc = -30d + 300 and RSm = - 10d + 100, and the relative errors were 5.4% and 5.6%. The R and d are in terms of cpm/mCi and cm. Besides, the collimators' impact was evaluated on the camera response, and the relevant equations were obtained by the Monte Carlo method. The calibrated equations as a function of various radiation angles on the center of camera's cells without using collimator indicated that both sources have the same quadratic coefficient by -2E-08 and same vertical width from the origin by 8E-05. CONCLUSION: The presented procedure may help determine the absorbed dose in the target and likewise optimize treatment planning.


Assuntos
Câmaras gama , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Radioisótopos/química , Compostos Radiofarmacêuticos/química , Samário/química , Tecnécio/química , Tomografia Computadorizada de Emissão de Fóton Único , Calibragem , Simulação por Computador , Método de Monte Carlo , Imagens de Fantasmas , Espalhamento de Radiação
2.
Indian J Nucl Med ; 30(3): 239-47, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26170567

RESUMO

PURPOSE: Estimation of Compton attenuation and the photoelectric absorption coefficients were explored at various depths. METHODS: A new method was proposed for estimating the depth based on the convolution of two exponential functions, namely convolution of scattering and primary functions (CSPF), which the convolved result will conform to the photopeak region of energy spectrum with the variable energy-window widths (EWWs) and a theory on the scattering cross-section. The triple energy-windows (TEW) and extended triple energy-windows scatter correction (ETEW) methods were used to estimate the scattered and primary photons according to the energy spectra at various depths due to a better performance than the other methods in nuclear medicine. For this purpose, the energy spectra were employed, and a distinct phantom along with a technetium-99 m source was simulated by Monte Carlo method. RESULTS: The simulated results indicate that the EWW, used to calculate the scattered and primary counts in terms of the integral operators on the functions, was proportional to the depth as an exponential function. The depth will be calculated by the combination of either TEW or ETEW and proposed method resulting in the distinct energy-window. The EWWs for primary photons were in good agreement with those of scattered photons at the same as depths. The average errors between these windows for both methods TEW, and ETEW were 7.25% and 6.03% at different depths, respectively. The EWW value for functions of scattered and primary photons was reduced by increasing the depth in the CSPF method. CONCLUSIONS: This coefficient may be an index for the scattering cross-section.

3.
Ann Nucl Med ; 29(4): 375-83, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25613356

RESUMO

OBJECTIVE: Improving signal to noise ratio (SNR) and qualified images by the various methods is very important for detecting the abnormalities at the body organs. Scatter and attenuation of photons by the organs lead to errors in radiopharmaceutical estimation as well as degradation of images. The choice of suitable energy window and the radionuclide have a key role in nuclear medicine which appearing the lowest scatter fraction as well as having a nearly constant linear attenuation coefficient as a function of phantom thickness. METHODS: The energy windows of symmetrical window (SW), asymmetric window (ASW), high window (WH) and low window (WL) using Tc-99m and Sm-153 radionuclide with solid water slab phantom (RW3) and Teflon bone phantoms have been compared, and Matlab software and Monte Carlo N-Particle (MCNP4C) code were modified to simulate these methods and obtaining the amounts of FWHM and full width at tenth maximum (FWTM) using line spread functions (LSFs). The experimental data were obtained from the Orbiter Scintron gamma camera. RESULTS: Based on the results of the simulation as well as experimental work, the performance of WH and ASW display of the results, lowest scatter fraction as well as constant linear attenuation coefficient as a function of phantom thickness. WH and ASW were optimal windows in nuclear medicine imaging for Tc-99m in RW3 phantom and Sm-153 in Teflon bone phantom. Attenuation correction was done for WH and ASW optimal windows and for these radionuclides using filtered back projection algorithm. Results of simulation and experimental show that very good agreement between the set of experimental with simulation as well as theoretical values with simulation data were obtained which was nominally less than 7.07 % for Tc-99m and less than 8.00 % for Sm-153. Corrected counts were not affected by the thickness of scattering material. The Simulated results of Line Spread Function (LSF) for Sm-153 and Tc-99m in phantom based on four windows and TEW method were indicated that the FWHM and FWTM values were approximately the same in TEW method and WH and ASW, but the sensitivity at the optimal window was more than that of the other one. CONCLUSIONS: The suitable determination of energy window width on the energy spectra can be useful in optimal design to improve efficiency and contrast. It is found that the WH is preferred to the ASW and the ASW is preferred to the SW.


Assuntos
Radioisótopos , Samário , Espalhamento de Radiação , Tecnécio , Algoritmos , Osso e Ossos/diagnóstico por imagem , Simulação por Computador , Câmaras gama , Modelos Biológicos , Método de Monte Carlo , Imagens de Fantasmas , Politetrafluoretileno , Cintilografia/instrumentação , Cintilografia/métodos , Razão Sinal-Ruído , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...