Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
MMWR Morb Mortal Wkly Rep ; 70(6): 208-211, 2021 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-33571175

RESUMO

Approximately 41% of adults aged 18-24 years in the United States are enrolled in a college or university (1). Wearing a face mask can reduce transmission of SARS-CoV-2, the virus that causes coronavirus disease 2019 (COVID-19) (2), and many colleges and universities mandate mask use in public locations and outdoors when within six feet of others. Studies based on self-report have described mask use ranging from 69.1% to 86.1% among adults aged 18-29 years (3); however, more objective measures are needed. Direct observation by trained observers is the accepted standard for monitoring behaviors such as hand hygiene (4). In this investigation, direct observation was used to estimate the proportion of persons wearing masks and the proportion of persons wearing masks correctly (i.e., covering the nose and mouth and secured under the chin*) on campus and at nearby off-campus locations at six rural and suburban universities with mask mandates in the southern and western United States. Trained student observers recorded mask use for up to 8 weeks from fixed sites on campus and nearby. Among 17,200 observed persons, 85.5% wore masks, with 89.7% of those persons wearing the mask correctly (overall correct mask use: 76.7%). Among persons observed indoors, 91.7% wore masks correctly. The proportion correctly wearing masks indoors varied by mask type, from 96.8% for N95-type masks and 92.2% for cloth masks to 78.9% for bandanas, scarves, and similar face coverings. Observed indoor mask use was high at these six universities with mask mandates. Colleges and universities can use direct observation findings to tailor training and messaging toward increasing correct mask use.


Assuntos
Máscaras/estatística & dados numéricos , Máscaras/normas , Saúde Pública/legislação & jurisprudência , Estudantes/psicologia , Universidades/legislação & jurisprudência , Adolescente , COVID-19/epidemiologia , COVID-19/prevenção & controle , Humanos , Estudantes/estatística & dados numéricos , Estados Unidos/epidemiologia , Adulto Jovem
2.
Eye Vis (Lond) ; 3: 20, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27478858

RESUMO

BACKGROUND: Femtosecond-laser assisted clear cornea cataract surgery may hold promise in safer and more effective procedures. We decided to perform a comparative study to standard manual incision phacoemulsification surgery. METHODS: This is a single-center, single-intervention, and prospective comparative data evaluation of 133 consecutive cases subjected to cataract surgery. Group-A (Phaco), manual capsulorhexis & ultrasound phacoemulsification (n = 66); Group-B femtosecond-laser assisted capsulorhexis and lens fragmentation (n = 67), employing the LenSx laser (Alcon Surgical, Ft. Worth, TX). All cases were evaluated for refraction, visual acuity, keratometry, tomography, pachymetry, endothelial cell counts, intraocular pressure, and type of intraocular lens (IOL) implanted. The groups were matched for age, gender, pre-operative vision metrics, and cataract grade, and were followed up to 1 year. RESULTS: In group-A post-operative uncorrected distance visual acuity (UDVA) was 20/20 or better in 61.5 % and 20/25 or better in 78.5 % of the eyes. The femtosecond laser group-B had improved outcomes (p = 0.075 and p = 0.042, respectively): post-operative UDVA was 20/20 or better in 62.7 % of the eyes and 20/25 or better in 85.1 %. Linear regression scatterplots of achieved versus attempted spherical equivalent had excellent regression coefficients (r (2) = 0.983 in group-A and 0.979 in group-B). There were 75.2 % cases in group-A and 80.6 % in group-B (p = 0.8732) within ±0.50 D of targeted refractive equivalent. Slight trend of under-correction was noted in group-A. Average residual manifest cylinder in the toric subgroup-A was -0.50 D (95 % Limit-of-Agreement (LoA) = -0.78 D), and in toric subgroup-B -0.45 D (LoA = -0.45 D). CONCLUSIONS: Mean spherical equivalent refraction and visual acuity are comparable with laser cataract surgery compared with manual capsulorhexis & ultrasound phacoemulsification. Improved astigmatism correction may be among the benefits of femtosecond laser-assisted cataract surgery. Transient corneal edema may be a first day transient disadvantage in femtosecond laser-assisted cataract surgery.

3.
Eye Vis (Lond) ; 3: 4, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26909354

RESUMO

BACKGROUND: To compare intraocular pressure (IOP) changes following topical dexamethasone administration for 1 month in keratoconic versus normal eyes. METHODS: This is a retrospective, single-center, non-randomized case series evaluation of 350 eyes. Two groups were formed: normal/control Group A (nA =73), eyes that underwent excimer laser photorefractive keratectomy; and keratoconic (KCN) Group B (nB =277), eyes that were subjected to partial laser photorefractive keratectomy combined with collagen cross-linking (The Athens Protocol). All eyes received the same post-operative regimen of topical dexamethasone 0.1 % for at least 1 month. Goldmann applanation tonometry IOP readings and central corneal thickness (CCT) measurements were monitored. Cases with induced ocular hypertension (OHT, defined as post-operative IOP higher than 21 mmHg), were identified and correlated to refractive procedure, gender, and corneal thickness. RESULTS: At 4 weeks postoperatively, OHT was noted on 27.4 % (20 /73 eyes) in Group A, and 43.7 % (121 /277 eyes) in KCN Group B, (p <0.01). Six months post-operatively (following 5-months of discontinuing topical dexamethasone treatment and commencing treatment of IOP-lowering medications), OHT rate was 1.8 % in Group A and 3.9 % in the KCN Group B. CONCLUSION: This study demonstrates a potentially significant pre-disposition of keratoconic eyes to the development of steroid-induced OHT.

4.
Cornea ; 35(4): 557-61, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26845317

RESUMO

PURPOSE: To evaluate ex vivo the possible difference in corneal cross-linking (CXL) biomechanical effect of different ultraviolet-A (UV-A) irradiances. METHODS: The study involved 25 human donor corneas, randomly allocated to 5 groups (n = 5 each). CXL was applied with UV-A irradiances of 3, 9, 18, 30, and 45 mW/cm2, maintaining equal cumulative energy dose of 5.4 J/cm2. UV-A was delivered on half of the cornea. The nonirradiated halves served as controls. Specimens were subjected to collagenase-A enzymatic digestion. The time to complete dissolution in each specimen was recorded. RESULTS: Time to dissolution in group-A (3 mW/cm2 for 30 minutes) was 321 ± 13.4 minutes (range: 300-330) compared with 171 ± 8.2 (range: 165-180) for their control. In group-B (9 mW/cm2 for 10 minutes), it was 282 ± 19.6 minutes (range: 270-315) compared with 177 ± 6.7 (165-180) for their control. In group-C (18 mW/cm2 for 5 minutes), it was 267 ± 19.6 minutes (range: 240-285) compared with 177 ± 7.7 (range: 165-180) for their control. In group-D (30 mW/cm2 for 3 minutes), it was 252 ± 12.5 minutes (range: 240-270) compared with 180 ± 10.6 minutes (range: 165-195) for their control. In group-E (45 mW/cm2 for 2 minutes), it was 204 ± 17.1 minutes (range: 180-225) compared with 186 ± 8.2 minutes (range: 180-195) for their control. CONCLUSIONS: The data in this ex vivo human corneal study indicate that the biomechanical effect of CXL studied by resistance to enzymatic digestion in human corneas is comparable between irradiances of 9, 18 and 30 mW/cm and seems to be reduced at a fluence of 45 mW/cm2.


Assuntos
Colágeno/metabolismo , Colagenases/farmacologia , Córnea/fisiologia , Reagentes de Ligações Cruzadas , Fármacos Fotossensibilizantes/farmacologia , Riboflavina/farmacologia , Terapia Ultravioleta , Idoso , Fenômenos Biomecânicos , Córnea/efeitos dos fármacos , Substância Própria/efeitos dos fármacos , Substância Própria/metabolismo , Relação Dose-Resposta à Radiação , Elasticidade/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doadores de Tecidos
5.
Eye Vis (Lond) ; 3: 1, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26783543

RESUMO

Dry eye is a multifactorial, progressive, and chronic disease of the tears and ocular surface. The disease is multi-factorial and has intermittent symptoms. Discomfort, visual disturbance, tear film instability with potential damage to the ocular surface, and increased tear film osmolarity are known associates. Dry eye is a common clinical problem for eye-care providers worldwide and there is a large number of clinical investigative techniques for the evaluation of dry eye. Despite this, however, there is no globally accepted guideline for dry eye diagnosis and none of the available tests may hold the title of the 'gold standard'. The majority of the techniques involved in the diagnosis of the disease, particularly for its early stages, has a large degree of subjectivity. The purpose of this article is to review existing dry eye investigative techniques and to present a new objective dry eye screening technique based on optical coherence tomography.

6.
J Refract Surg ; 31(11): 768-73, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26544565

RESUMO

PURPOSE: To comparatively investigate the efficacy of the enhanced Athens Protocol procedure guided by novel Placido-derived topography with cyclorotation compensation (the cyclorotation adjusted group) to similar cases guided by Scheimpflug-derived tomography without cyclorotation compensation (the non-cyclorotation adjusted group). METHODS: Two groups were evaluated: the cyclorotation adjusted group (n = 110 eyes) and the non-cyclorotation adjusted group (n = 110 eyes). Analysis was based on digital processing of Scheimpflug imaging derived curvature difference maps preoperatively and 3 months postoperatively. The vector (r, ϑ) corresponding to the steepest corneal point (cone) on the preoperative surgical planning map (rp, ϑp) and on the curvature difference map (rd, ϑd) were computed. The differences between the peak topographic angular data (Δϑ = |ϑp - ϑd|) and weighted angular difference (WΔϑ = Δϑ × Δr) were calculated. RESULTS: For the cyclorotation adjusted group, Δϑ was 7.18° ± 7.53° (range: 0° to 34) and WΔϑ was 3.43 ± 4.76 mm (range: 0.00 to 21.41 mm). For the non-cyclorotation adjusted group, Δϑ was 14.50° ± 12.65° (range: 0° to 49°) and WΔϑ was 10.23 ± 15.15 mm (range: 0.00 to 80.56 mm). The cyclorotation adjusted group appeared superior to the non-cyclorotation adjusted group, in both the smaller average angular difference between attempted to achieved irregular curvature normalization and in weighted angular difference, by a statistically significant margin (Δϑ: P = .0058; WΔϑ: P = .015). CONCLUSIONS: This study suggests that employment of the novel Placido-derived topographic data of highly irregular corneas, such as in keratoconus, treated with topography-guided profile with cyclorotation compensation leads to markedly improved cornea normalization.


Assuntos
Topografia da Córnea/métodos , Ceratocone/terapia , Lasers de Excimer/uso terapêutico , Fotoquimioterapia , Ceratectomia Fotorrefrativa/métodos , Cirurgia Assistida por Computador , Adolescente , Adulto , Colágeno/metabolismo , Terapia Combinada , Substância Própria/metabolismo , Feminino , Seguimentos , Humanos , Ceratocone/tratamento farmacológico , Ceratocone/metabolismo , Ceratocone/cirurgia , Masculino , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Retrospectivos , Riboflavina/uso terapêutico , Raios Ultravioleta , Acuidade Visual/fisiologia , Adulto Jovem
7.
J Refract Surg ; 31(9): 628-32, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26352569

RESUMO

PURPOSE: To evaluate corneal stromal thickness reduction and compare to attempted and achieved ablation depth in a consecutive case series study of myopic LASIK. METHODS: Stromal thickness reduction was retrospectively evaluated in 205 consecutive eyes of 205 patients undergoing myopic and myopic astigmatic LASIK. Anterior segment optical coherence tomography was performed preoperatively and 3 months postoperatively. Epithelial thickness remodeling was also accounted for to achieve objective stromal thickness reduction. The derived maximum stromal thickness reduction was then compared to the programmed (planned) maximum ablation depth. Deviation of planned versus achieved maximum stromal thickness changes was correlated with residual refractive error. RESULTS: The 3-month stromal reduction was 86.01 ± 28.28 µm, compared to the average programmed maximum ablation depth of 88.48 ± 26.05 µm. The attempted versus achieved thickness outliers correlated with deviations in achieved refractive correction. CONCLUSIONS: Actual objective stromal thickness reduction following myopic LASIK correlates well with the attempted versus achieved refractive change.


Assuntos
Substância Própria/patologia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Adulto , Paquimetria Corneana , Substância Própria/cirurgia , Feminino , Análise de Fourier , Humanos , Masculino , Pessoa de Meia-Idade , Miopia/fisiopatologia , Tamanho do Órgão , Refração Ocular/fisiologia , Estudos Retrospectivos , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia , Adulto Jovem
8.
J Cataract Refract Surg ; 41(7): 1426-33, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26287881

RESUMO

PURPOSE: To evaluate the safety, efficacy, and refractive and keratometric stability of myopic femtosecond laser in situ keratomileusis (LASIK) with concurrent prophylactic high-fluence corneal collagen crosslinking (CXL) compared with the outcomes of standard femtosecond LASIK. SETTING: Private clinical practice, Athens, Greece. DESIGN: Consecutive randomized prospective comparative study. METHODS: Eyes that had myopic LASIK or myopic LASIK with concurrent high-fluence CXL were evaluated preoperatively and up to 2 years postoperatively for manifest refraction spherical equivalent (MRSE), refractive astigmatism, visual acuity, corneal keratometry (K), and endothelial cell count. RESULTS: One hundred forty consecutive eyes had myopic LASIK; 65 of the eyes were treated additionally with CXL. In the LASIK-CXL eyes, the mean postoperative MRSE was -0.18 diopter (D) ± 17.0 (SD) from -6.67 ± 2.14 D preoperatively. The postoperative flat K was 37.67 D from 43.92 D, and the steep K was 38.38 D from 45.15 D. The correlation coefficient of SE correction predictability was 0.975. In the LASIK-only eyes, the mean postoperative MRSE was -0.32 ± 0.24 D from -5.49 ± 1.99 D preoperatively. The flat K was 38.04 D from 43.15 D, and the steep K was 38.69 D from 44.03 D. The correlation coefficient of SE correction predictability was 0.968. The differences between the 2 groups at the 20/20 and 20/25 levels were statistically significant (P = .045 and P = .039, respectively). CONCLUSION: Two-year results indicate that the application of prophylactic CXL concurrently with high-myopic LASIK appears to improve refractive and keratometric stability, presumably by affecting corneal biomechanical properties. FINANCIAL DISCLOSURE: Dr. Kanellopoulos is a consultant to Alcon Surgical, Inc., Wavelight Laser Technologie AG, Allergan, Inc., Avedro, Inc., and i-Optics Corp. Dr. Asimellis has no financial or proprietary interest in any material or method mentioned.


Assuntos
Colágeno/metabolismo , Substância Própria/metabolismo , Reagentes de Ligações Cruzadas , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Miopia Degenerativa/terapia , Fármacos Fotossensibilizantes/uso terapêutico , Adolescente , Adulto , Contagem de Células , Terapia Combinada , Paquimetria Corneana , Endotélio Corneano/patologia , Feminino , Seguimentos , Humanos , Lasers de Excimer/efeitos adversos , Masculino , Miopia Degenerativa/tratamento farmacológico , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/cirurgia , Fármacos Fotossensibilizantes/efeitos adversos , Estudos Prospectivos , Refração Ocular/fisiologia , Riboflavina/uso terapêutico , Retalhos Cirúrgicos , Tomografia de Coerência Óptica , Resultado do Tratamento , Acuidade Visual/fisiologia , Adulto Jovem
9.
Cornea ; 34(8): 937-44, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26057324

RESUMO

PURPOSE: To evaluate and investigate the distribution and repeatability of anterior corneal surface astigmatism measurements (axis and magnitude) using a novel corneal topographer. METHODS: Anterior corneal surface astigmatism was investigated in a total of 195 eyes using a novel multicolored spot reflection topographer (Cassini; i-Optics). Two patient groups were studied, a younger-age group A and an older-age group B. Three consecutive acquisitions were obtained from each eye. The repeatability of measurement was assessed using Bland-Altman plot analysis and is reported as the coefficient of repeatability. RESULTS: Group A (average age 34.3 years) had on average with-the-rule astigmatism, whereas the older-age group B (average age 72.3 years) had on average against-the-rule astigmatism. Average astigmatism magnitude measurement repeatability in group A was 0.4 diopters (D) and in group B 0.4 D. Average astigmatism axis measurement repeatability in group A was 5.4 degrees and in group B 5.5 degrees. The axis measurement repeatability improved with increasing magnitude of astigmatism: in the subgroups with astigmatism between 3.0 and 6.0 D, the axis repeatability was 1.4 degrees (group A) and 1.2 degrees (group B), whereas in the subgroups with astigmatism larger than 6.0 D, the repeatability was 1.1 and 0.6 degrees, respectively. CONCLUSIONS: This novel corneal topography device seems to offer high precision in reporting corneal astigmatism. This study reaffirms the established trend of a corneal astigmatism shift from an average "with-the-rule" to "against-the-rule" with aging.


Assuntos
Astigmatismo/diagnóstico , Córnea/patologia , Topografia da Córnea/instrumentação , Adolescente , Adulto , Idoso , Envelhecimento/fisiologia , Astigmatismo/fisiopatologia , Cor , Feminino , Seguimentos , Humanos , Luz , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
11.
Br J Ophthalmol ; 99(6): 870-4, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25795914

RESUMO

BACKGROUND/AIMS: To evaluate ex vivo biomechanical and enzymatic digestion resistance differences between standard myopic laser in-situ keratomileusis (LASIK) compared with LASIK+CXL, in which high-irradiance cross-linking (CXL) is added. METHODS: Eight human donor corneas were subjected to femtosecond-assisted myopic LASIK. Group A (n=4) served as a control group (no CXL). The corneas in LASIK+CXL group B were subjected to concurrent prophylactic high-irradiance CXL (n=4). Saline-diluted (0.10%) riboflavin was instilled on the stroma, subsequently irradiated with UV-A through the repositioned flap. The cornea stroma and flap specimens were separately subjected to transverse biaxial resistance measurements; biomechanical differences were assessed via stress and Young's shear modulus. Subsequently, the specimens were subjected to enzymatic degradation. RESULTS: For the corneal stroma specimen, stress at 10% strain was 128±11 kPa for control group A versus 293±20 kPa for the LASIK+CXL group B (relative difference Δ=+129%, p<0.05). The stress in group B was also increased at 20% strain by +68% (p<0.05). Shear modulus in group B was increased at 10% strain by +79%, and at 20% strain by +48% (both statistically significant, p<0.05). The enzymatic degradation time to dissolution was 157.5±15.0 min in group A versus 186.25±7.5 min in group B (Δ=+18%, p=0.014). For the flaps, both biomechanical, as well as enzymatic degradation tests showed no significant differences. CONCLUSIONS: LASIK+CXL appears to provide significant increase in underlying corneal stromal rigidity, up to +130%. Additionally, there is significant relevant enzymatic digestion resistance confirmatory to the above. LASIK flaps appear unaffected biomechanically by the LASIK+CXL procedure, suggesting effective CXL just under the flap.


Assuntos
Substância Própria/fisiologia , Reagentes de Ligações Cruzadas , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Miopia/terapia , Fotoquimioterapia , Retalhos Cirúrgicos/fisiologia , Adulto , Idoso , Fenômenos Biomecânicos , Terapia Combinada , Córnea/efeitos dos fármacos , Córnea/cirurgia , Elasticidade/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miopia/tratamento farmacológico , Miopia/cirurgia , Fármacos Fotossensibilizantes/uso terapêutico , Riboflavina/uso terapêutico , Doadores de Tecidos , Raios Ultravioleta
12.
J Refract Surg ; 31(3): 164-9, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25751832

RESUMO

PURPOSE: To objectively define the effective centration of myopic femtosecond laser-assisted LASIK ablation pattern, evaluate the difference between achieved versus planned excimer laser ablation centration, and compare these results from two different generations of an excimer laser system. METHODS: The study retrospectively evaluated 280 eyes subjected to myopic LASIK. Digital image analysis was performed on Scheimpflug sagittal curvature maps (difference of preoperative to postoperative). Centration was assessed via proprietary software digital analysis of the coordinate displacement between the achieved ablation geometric center and the planned ablation center, which was the corneal vertex. Results from two different excimer laser generations (Eye-Q 400 [140 eyes] and EX500 [140 eyes]; Alcon/WaveLight, Fort Worth, TX) were compared. RESULTS: Radial displacement was on average 360 ± 220 µm (range: 0 to 1,030 µm) in the Eye-Q 400 laser group and 120 ± 110 µm (range: 0 to 580 µm) in the EX500 laser group (P < .01). The percentage of eyes with displacement of greater than 300 µm was 52% in the Eye-Q 400 laser group and 4% in the EX500 laser group. CONCLUSIONS: Displacement of ablation pattern may depend on the laser platform used. The improvement in the efficiency of centration indicates that newer generation excimer lasers with faster eye tracking and active centration control appear to achieve a significantly more accurate centration of myopic ablation patterns. The authors propose this novel, objective technique for laser refractive surgeon evaluation may point out significant outcome measures not currently used in standard metrics of refractive laser efficiency.


Assuntos
Astigmatismo/cirurgia , Substância Própria/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Adolescente , Adulto , Topografia da Córnea , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Retalhos Cirúrgicos , Adulto Jovem
13.
Cornea ; 34(5): 550-6, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25651497

RESUMO

PURPOSE: To evaluate biomechanical changes induced by in situ corneal cross-linking (CXL) with stromal pocket delivered enhanced concentration riboflavin and high-fluence, high-energy UV-A irradiation. METHODS: Eight human donor corneas were subjected to intrastromal lamellar corneal tissue removal of anterior 140-µm deep, 80-µm thick × 5-mm diameter central stromal buttons, extracted through a 3.5-mm width tunnel, surfacing in the superior cornea periphery. Enhanced concentration riboflavin solution (0.25%) was instilled in the pocket. In study group A (CXL), superficial high-fluence UV-A irradiation was applied, whereas in control group B (no CXL), none. To comparatively assess changes in corneal rigidity, corneal specimens were subjected to transverse biaxial resistance measurements by application of a unidirectional tangential shear force. Biomechanical differences were evaluated through stress and Young shear modulus. RESULTS: Stress at 10% strain was 305 ± 24 kPa in study group A versus 157 ± 11 kPa in control group B (relative difference Δ = 107%, P = 0.021). Stress at 20% strain was 1284 ± 34 kPa in study group A versus 874 ± 29 kPa in control group B (Δ = 47%, P = 0.043). Average shear modulus in study group A at 10% strain was 6.98 ± 1.12 MPa versus 4.04 ± 0.85 MPa in control group B (Δ = 73%, P = 0.036). Average shear modulus in study group A at 20% strain was 11.46 ± 0.75 MPa versus 8.80 ± 0.72 MPa in group B (Δ = 30%, P = 0.047). CONCLUSIONS: Adjunct CXL in this ex vivo simulation refractive lens extraction procedure seems to provide significant increase in corneal rigidity, up to +107%. These findings also support our previous reported work on laser in situ keratomileusis combined with CXL.


Assuntos
Extração de Catarata , Colágeno/metabolismo , Córnea/efeitos dos fármacos , Córnea/fisiologia , Reagentes de Ligações Cruzadas , Fármacos Fotossensibilizantes/uso terapêutico , Riboflavina/uso terapêutico , Idoso , Fenômenos Biomecânicos , Paquimetria Corneana , Substância Própria/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doadores de Tecidos , Tomografia de Coerência Óptica , Raios Ultravioleta
14.
J Cataract Refract Surg ; 41(2): 408-14, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25661135

RESUMO

PURPOSE: To compare postoperative changes in apparent photopic and mesopic pupil size and centration in relation to cornea reflection landmarks after cataract surgery. SETTING: LaserVision.gr Clinical and Research Eye Institute, Athens, Greece. DESIGN: Prospective consecutive case study. METHODS: Pupils were imaged for pupil size and corneal vertex location before and 1-month after cataract surgery. Digital analysis of pupil images was used to determine the Cartesian coordinates (nasal-temporal, horizontal axis, superior-inferior, vertical axis) of the first Purkinje reflection point (approximating the corneal intersection of the visual axis [corneal vertex]) to the pupil geometric center (approximating the corneal intersection of the line of sight [corneal apex]). Pupil size changes were measured, and the correlation between vertex-to-apex shift changes and postoperative pupil centroid shift was evaluated. RESULTS: The study evaluated 40 eyes. The pupil size (diameter) change corresponded to a relative reduction of -9.8% for photopic pupils and -9.1% for mesopic pupils; the difference was statistically significant (P = .045 and P = .011, respectively). Also, there was a reduction in the centroid shift (all eyes) from a mean of 0.12 mm preoperatively to 0.05 mm postoperatively as a result of the postoperative minus temporal horizontal difference between the corneal vertex and the apex. CONCLUSIONS: Cataract extraction surgery appears to affect pupil size and centration. Specifically, a smaller pupil and less temporal shift were recorded. These data may have clinical relevance in targeted intraoperative intraocular lens centration. FINANCIAL DISCLOSURE: Dr. Kanellopoulos is a consultant to Alcon Surgical, Inc., Wavelight Laser Technologie AG, Allergan, Avedro, Inc., and i-Optics Corp. No author has a financial or proprietary interest in any material or method mentioned.


Assuntos
Técnicas de Diagnóstico Oftalmológico/instrumentação , Implante de Lente Intraocular , Facoemulsificação , Pupila/fisiologia , Idoso , Idoso de 80 Anos ou mais , Visão de Cores/fisiologia , Córnea/anatomia & histologia , Feminino , Humanos , Masculino , Visão Mesópica/fisiologia , Pessoa de Meia-Idade , Midríase/fisiopatologia , Estudos Prospectivos
15.
Clin Ophthalmol ; 9: 245-52, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25709385

RESUMO

PURPOSE: To investigate repeatability of steep and flat keratometry measurements, as well as astigmatism axis in cohorts with normal range and regular astigmatic such as: eyes following laser-assisted in situ keratomileusis (LASIK) and normal population, as well as cohorts of high and irregular astigmatism such as keratoconic eyes, and keratoconic eyes following corneal collagen cross-linking, employing a novel corneal reflection topography device. METHODS: Steep and flat keratometry and astigmatism axis measurement repeatability was investigated employing a novel multicolored-spot reflection topographer (Cassini) in four study groups, namely a post myopic LASIK-treated Group A, a keratoconus Group B, a post-CXL keratoconus Group C, and a control Group D of routine healthy patients. Three separate, maps were obtained employing the Cassini, enabling investigation of the intra-individual repeatability by standard deviation. Additionally we investigated in all groups,the Klyce surface irregularity indices for keratoconus, the SAI (surface asymmetry index) and the SRI (surface regularity index). RESULTS: Flat keratometry repeatability was 0.74±0.89 (0.03 to 5.26) diopters (D) in the LASIK Group A, 0.88±1.45 (range minimum to maximum, 0.00 to 7.84) D in the keratoconic Group B, and 0.71±0.94 (0.02 to 6.23) D in the cross-linked Group C. The control Group D had flat keratometry repeatability 0.36±0.46 (0.00 to 2.71) D. Steep keratometry repeatability was 0.64±0.82 (0.01 to 4.81) D in the LASIK Group A, 0.89±1.22 (0.02 to 7.85) D in the keratoconic Group B, and 0.93±1.12 (0.04 to 5.93) D in the cross-linked Group C. The control Group D had steep keratometry repeatability 0.41±0.50 (0.00 to 3.51) D. Axis repeatability was 3.45±1.62° (0.38 to 7.78°) for the LASIK Group A, 4.12±3.17° (0.02 to 12.13°) for the keratoconic Group B, and 3.20±1.99° (0.17 to 8.61°) for the cross-linked Group C. The control Group D had axis repeatability 2.16±1.39° (0.05 to 5.86°). The SAI index measurement repeatability was 0.33±0.40 (0.01 to 2.31) in the post-LASIK Group A, 0.39±0.75 (0.00 to 7.15) in the keratoconic Group B, and 0.43±0.56 (0.05 to 3.50) in the keratoconus post-CXL Group C. The control group had SAI measurement repeatability of 0.26±0.30 (0.00 to 2.39). The SRI index repeatability was 0.22±0.17 (0.01 to 0.96) for post-LASIK Group A, 0.20±0.18 (0.00 to 1.07) in keratoconic Group B, and 0.13±0.09 (0.00 to 0.45) in the keratoconus post-CXL Group C. The control Group D had SRI measurement repeatability of 0.23±0.16 (0.00 to 0.75). CONCLUSION: This novel corneal topography device appears to offer very high specificity in estimating corneal keratometry and specific corneal irregularity indices, even in topographically challenging corneas such as LASIK treated, keratoconic, and cross-linked.

16.
Clin Ophthalmol ; 8: 2425-33, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25506204

RESUMO

PURPOSE: To report novel application of topographically-customized collagen crosslinking aiming to achieve hyperopic refractive changes. Two approaches were evaluated, one based on epithelium-off and one based on epithelium-on (transepithelial). METHODS: A peripheral annular-shaped topographically customizable design was employed for high-fluence ultraviolet (UV)-A irradiation aiming to achieve hyperopic refractive changes. A total of ten eyes were involved in this study. In group-A (five eyes), a customizable ring pattern was employed to debride the epithelium by excimer laser ablation, while in group-B (also five eyes), the epithelium remained intact. In both groups, specially formulated riboflavin solutions were applied. Visual acuity, cornea clarity, keratometry, topography, and pachymetry with a multitude of modalities, as well as endothelial cell counts were evaluated. RESULTS: One year postoperatively, the following changes have been noted: in group-A, average uncorrected distance visual acuity changed from 20/63 to 20/40. A mean hyperopic refractive increase of +0.75 D was achieved. There was some mild reduction in the epithelial thickness. In group-B, average uncorrected distance visual acuity changed from 20/70 to 20/50. A mean hyperopic refractive increase of +0.85 D was achieved. Epithelial thickness returned to slightly reduced levels (compared to baseline) in group-A, whereas to slightly increased levels in group-B. CONCLUSION: We introduce herein the novel application of a topographically-customizable collagen crosslinking to achieve a hyperopic refractive effect. This novel technique may be applied either with epithelial removal, offering a more stable result or with a non-ablative and non-incisional approach, offering a minimally invasive alternative.

17.
Clin Ophthalmol ; 8: 2373-81, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25473264

RESUMO

PURPOSE: To compare 1-year results: safety, efficacy, refractive and keratometric stability, of femtosecond myopic laser-assisted in situ keratomileusis (LASIK) with and without concurrent prophylactic high-fluence cross-linking (CXL) (LASIK-CXL). METHODS: We studied a total of 155 consecutive eyes planned for LASIK myopic correction. Group A represented 73 eyes that were treated additionally with concurrent prophylactic high-fluence CXL; group B included 82 eyes subjected to the stand-alone LASIK procedure. The following parameters were evaluated preoperatively and up to 1-year postoperatively: manifest refractive spherical equivalent (MRSE), refractive astigmatism, visual acuity, corneal keratometry, and endothelial cell counts. We plotted keratometry measurements pre-operatively and its change in the early, interim and later post-operative time for the two groups, as a means of keratometric stability comparison. RESULTS: Group A (LASIK-CXL) had an average postoperative MRSE of -0.23, -0.19, and -0.19 D for the 3-, 6-, and 12-month period, respectively, compared to -6.58±1.98 D preoperatively. Flat keratometry was 37.69, 37.66, and 37.67 D, compared to 43.94 D preoperatively, and steep keratometry was 38.35, 38.36, and 38.37 D, compared to 45.17 D preoperatively. The predictability of Manifest Refraction Spherical Equivalent (MRSE) correction showed a correlation coefficient of 0.979. Group B (stand-alone LASIK) had an average postoperative MRSE of -0.23, -0.20, and -0.27 D for the 3-, 6-, and 12-month period, respectively, compared with -5.14±2.34 D preoperatively. Flat keratometry was 37.65, 37.89, and 38.02 D, compared with 43.15 D preoperatively, and steep keratometry was 38.32, 38.57, and 38.66 D, compared with 44.07 D preoperatively. The predictability of MRSE correction showed a correlation coefficient of 0.970. The keratometric stability plots were stable for the LASIK CXL group and slightly regressing in the standard LASIK group, a novel stability evaluation metric that may escape routine acuity and refraction measurements. CONCLUSION: Application of prophylactic CXL concurrently with myopic LASIK surgery appears to contribute to improved refractive and keratometric stability compared to standard LASIK. The procedure appears safe and provides a new potential for LASIK correction.

18.
Clin Ophthalmol ; 8: 2141-50, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25368512

RESUMO

PURPOSE: To investigate, by high-precision digital analysis of data provided by Scheimpflug imaging, changes in pupil size and shape and anterior chamber (AC) parameters following cataract surgery. PATIENTS AND METHODS: The study group (86 eyes, patient age 70.58±10.33 years) was subjected to cataract removal surgery with in-the-bag intraocular lens implantation (pseudophakic). A control group of 75 healthy eyes (patient age 51.14±16.27 years) was employed for comparison. Scheimpflug imaging (preoperatively and 3 months postoperatively) was employed to investigate central corneal thickness, AC depth, and AC volume. In addition, by digitally analyzing the black-and-white dotted line pupil edge marking in the Scheimpflug "large maps," the horizontal and vertical pupil diameters were individually measured and the pupil eccentricity was calculated. The correlations between AC depth and pupil shape parameters versus patient age, as well as the postoperative AC and pupil size and shape changes, were investigated. RESULTS: Compared to preoperative measurements, AC depth and AC volume of the pseudophakic eyes increased by 0.99±0.46 mm (39%; P<0.001) and 43.57±24.59 mm(3) (36%; P<0.001), respectively. Pupil size analysis showed that the horizontal pupil diameter was reduced by -0.27±0.22 mm (-9.7%; P=0.001) and the vertical pupil diameter was reduced by -0.32±0.24 mm (-11%; P<0.001). Pupil eccentricity was reduced by -39.56%; P<0.001. CONCLUSION: Cataract extraction surgery appears to affect pupil size and shape, possibly in correlation to AC depth increase. This novel investigation based on digital analysis of Scheimpflug imaging data suggests that the cataract postoperative photopic pupil is reduced and more circular. These changes appear to be more significant with increasing patient age.

19.
Case Rep Ophthalmol ; 5(3): 311-7, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25408671

RESUMO

This case report aims to evaluate safety, efficacy and feasibility of anterior surface imaging by a novel point-source reflection topographer, in comparison to four other corneal imaging modalities. A 17-year-old female patient, clinically diagnosed with chronic herpetic keratitis in her left eye was imaged by a novel multicolored-spot reflection topography system. We comparatively investigated elevation and curvature maps between the novel topographer and established Placido disk topography and Scheimpflug tomography systems. Pachymetry maps were compared between the Scheimpflug system and anterior-segment optical coherence tomography system. The Placido system failed to properly register the abnormal anterior surface due to incomplete mire registration, while the Scheimpflug topometry device imaged the anterior surface properly, but not the posterior (due to media opacity), and thus pachymetry was highly irregular and erroneous in this case. Imaging of corneas infected with herpes simplex virus keratitis has been rare; we have not identified any such documentation in the peer review literature in the last 10 years. This novel multicolored-spot reflection topography imaging may offer successful corneal imaging in cases where established clinical topography systems may fail to produce accurate reconstruction of the corneal shape. This is an important case demonstrating exceptional clinical feasibility in such rare cases offered by a newly introduced technology in ophthalmic imaging.

20.
Clin Ophthalmol ; 8: 2277-87, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25429197

RESUMO

PURPOSE: To investigate epithelial thickness-distribution characteristics in a large group of keratoconic patients and their correlation to normal eyes employing anterior-segment optical coherence tomography (AS-OCT). MATERIALS AND METHODS: The study group (n=160 eyes) consisted of clinically diagnosed keratoconus eyes; the control group (n=160) consisted of nonkeratoconic eyes. Three separate, three-dimensional epithelial thickness maps were obtained employing AS-OCT, enabling investigation of the pupil center, average, mid-peripheral, superior, inferior, maximum, minimum, and topographic epithelial thickness variability. Intraindividual repeatability of measurements was assessed. We introduced correlation of the epithelial data via newly defined indices. The epithelial thickness indices were then correlated with two Scheimpflug imaging-derived AS-irregularity indices: the index of height decentration, and the index of surface variance highly sensitive to early and advancing keratoconus diagnosis as validation. RESULTS: Intraindividual repeatability of epithelial thickness measurement in the keratoconic group was on average 1.67 µm. For the control group, repeatability was on average 1.13 µm. In the keratoconic group, pupil-center epithelial thickness was 51.75±7.02 µm, while maximum and minimum epithelial thickness were 63.54±8.85 µm and 40.73±8.51 µm. In the control group, epithelial thickness at the center was 52.54±3.23 µm, with maximum 55.33±3.27 µm and minimum 48.50±3.98 µm epithelial thickness. Topographic variability was 6.07±3.55 µm in the keratoconic group, while for the control group it was 1.59±0.79 µm. In keratoconus, topographic epithelial thickness change from normal, correlated tightly with the topometric asymmetry indices of IHD and ISV derived from Scheimpflug imaging. CONCLUSION: Simple, OCT-derived epithelial mapping, appears to have critical potential in early and advancing keratoconus diagnosis, confirmed with its correlation with established Scheimpflug-derived asymmetry topometric indices.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...