Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
2.
Med Eng Phys ; 37(7): 674-82, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26003286

RESUMO

This paper presents a novel method for discrimination between innocent and pathological murmurs using the growing time support vector machine (GTSVM). The proposed method is tailored for characterizing innocent murmurs (IM) by putting more emphasis on the early parts of the signal as IMs are often heard in early systolic phase. Individuals with mild to severe aortic stenosis (AS) and IM are the two groups subjected to analysis, taking the normal individuals with no murmur (NM) as the control group. The AS is selected due to the similarity of its murmur to IM, particularly in mild cases. To investigate the effect of the growing time windows, the performance of the GTSVM is compared to that of a conventional support vector machine (SVM), using repeated random sub-sampling method. The mean value of the classification rate/sensitivity is found to be 88%/86% for the GTSVM and 84%/83% for the SVM. The statistical evaluations show that the GTSVM significantly improves performance of the classification as compared to the SVM.


Assuntos
Sopros Cardíacos/classificação , Fonocardiografia/métodos , Máquina de Vetores de Suporte , Adolescente , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/classificação , Estenose da Valva Aórtica/fisiopatologia , Criança , Pré-Escolar , Bases de Dados Factuais , Sopros Cardíacos/fisiopatologia , Humanos , Lactente , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Análise de Ondaletas
3.
Med Eng Phys ; 36(4): 477-83, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24613501

RESUMO

In this paper, we present a novel neural network for classification of short-duration heart sounds: the time growing neural network (TGNN). The input to the network is the spectral power in adjacent frequency bands as computed in time windows of growing length. Children with heart systolic ejection click (SEC) and normal children are the two groups subjected to analysis. The performance of the TGNN is compared to that of a time delay neural network (TDNN) and a multi-layer perceptron (MLP), using training and test datasets of similar sizes with a total of 614 normal and abnormal cardiac cycles. From the test dataset, the classification rate/sensitivity is found to be 97.0%/98.1% for the TGNN, 85.1%/76.4% for the TDNN, and 92.7%/85.7% for the MLP. The results show that the TGNN performs better than do TDNN and MLP when frequency band power is used as classifier input. The performance of TGNN is also found to exhibit better immunity to noise.


Assuntos
Ruídos Cardíacos , Redes Neurais de Computação , Processamento de Sinais Assistido por Computador , Sístole/fisiologia , Algoritmos , Valva Aórtica/anormalidades , Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide , Criança , Pré-Escolar , Simulação por Computador , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Curva ROC , Sensibilidade e Especificidade , Fatores de Tempo
4.
Biomed Eng Online ; 12: 64, 2013 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-23827015

RESUMO

BACKGROUND: ECG (Electrocardiogram) measurements in home health care demands new sensor solutions. In this study, six different configurations of screen printed conductive ink electrodes have been evaluated with respect to electrode potential variations and electrode impedance. METHODS: The electrode surfaces consisted of a Ag/AgCl-based ink with a conduction line of carbon or Ag-based ink underneath. On top, a lacquer layer was used to define the electrode area and to cover the conduction lines. Measurements were performed under well-defined electro-chemical conditions in a physiologic saline solution. RESULTS: The results showed that all printed electrodes were stable and have a very small potential drift (less than 3 mV/30 min). The contribution to the total impedance was 2% of the set maximal allowed impedance (maximally 1 kΩ at 50 Hz), assuming common values of input impedance and common mode rejection ratio of a regular amplifier. CONCLUSION: Our conclusions are that the tested electrodes show satisfying properties to be used as elements in a skin electrode design that could be suitable for further investigations by applying the electrodes on the skin.


Assuntos
Eletrocardiografia/instrumentação , Impressão , Impedância Elétrica , Eletrodos , Humanos , Prata , Compostos de Prata , Pele , Propriedades de Superfície
5.
PLoS One ; 8(7): e70404, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23894650

RESUMO

Occurrence of cannibalism and inferior competitive ability of predators compared to their prey have been suggested to promote coexistence in size-structured intraguild predation (IGP) systems. The intrinsic size-structure of fish provides the necessary prerequisites to test whether the above mechanisms are general features of species interactions in fish communities where IGP is common. We first experimentally tested whether Arctic char (Salvelinus alpinus) were more efficient as a cannibal than as an interspecific predator on the prey fish ninespine stickleback (Pungitius pungitius) and whether ninespine stickleback were a more efficient competitor on the shared zooplankton prey than its predator, Arctic char. Secondly, we performed a literature survey to evaluate if piscivores in general are more efficient as cannibals than as interspecific predators and whether piscivores are inferior competitors on shared resources compared to their prey fish species. Both controlled pool experiments and outdoor pond experiments showed that char imposed a higher mortality on YOY char than on ninespine sticklebacks, suggesting that piscivorous char is a more efficient cannibal than interspecific predator. Estimates of size dependent attack rates on zooplankton further showed a consistently higher attack rate of ninespine sticklebacks compared to similar sized char on zooplankton, suggesting that ninespine stickleback is a more efficient competitor than char on zooplankton resources. The literature survey showed that piscivorous top consumers generally selected conspecifics over interspecific prey, and that prey species are competitively superior compared to juvenile piscivorous species in the zooplankton niche. We suggest that the observed selectivity for cannibal prey over interspecific prey and the competitive advantage of prey species over juvenile piscivores are common features in fish communities and that the observed selectivity for cannibalism over interspecific prey has the potential to mediate coexistence in size structured intraguild predation systems.


Assuntos
Canibalismo , Peixes/fisiologia , Comportamento Predatório , Animais , Cadeia Alimentar
6.
Stud Health Technol Inform ; 177: 71-5, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22942033

RESUMO

NovaMedTech is an initiative funded from EU structural funds for supporting new medical technologies for personalized health care. It aims at bringing these technologies into clinical use and to the health care market. The program has participants from health care, industry and academia in East middle Sweden. The first three year period of the program was successful in terms of product concepts tried clinically, and number of products brought to a commercialization phase. Further, the program has led to a large number of scientific publications. Among projects supported, we can mention: Intelligent sensor networks; A digital pen to collect medical information about health status from patients; A web-based intelligent stethoscope; Methodologies to measure local blood flow and nutrition using optical techniques; Blood flow assessment from ankle pressure measurements; Technologies for pressure ulcer prevention; An IR thermometer for improved accuracy; A technique that identifies individuals prone to commit suicide among depressed patients; Detection of infectious disease using an electronic nose; Identification of the lactate threshold from breath; Obesity measurements using special software and MR camera; and An optical probe guided tumor resection. During the present three years period emphasis will be on entrepreneurial activities supporting the commercialization and bringing products to the market.


Assuntos
Tecnologia Biomédica/organização & administração , Atenção à Saúde/organização & administração , Programas Governamentais , Monitorização Ambulatorial/métodos , Medicina de Precisão/métodos , Telemedicina/organização & administração , Europa (Continente)
7.
Ecology ; 90(7): 1923-32, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19694140

RESUMO

This study quantified new biomass production of algae and bacteria in both benthic and pelagic habitats of clear-water lakes to contrast how carbon from the atmosphere and terrestrial sources regulates whole-lake metabolism. We studied four small unproductive lakes in subarctic northern Sweden during one summer season. The production of new biomass in both benthic and pelagic habitats was calculated as the sum of autotrophic production by algae and heterotrophic production by bacteria using allochthonous organic carbon (OC). Whole-lake production of new biomass was dominated by the benthic habitat (86% +/- 4% [mean +/- SD]) and by primary production (77% +/- 9%). Still, heterotrophic bacteria fueled by allochthonous OC constituted a significant portion of the new biomass production in both benthic (19% +/- 11%) and pelagic habitats (51% +/- 24%). In addition, overall net production (primary production minus respiration) was close to zero in the benthic habitats but highly negative (-163 +/- 81 mg C x m(-2) x d(-1)) in pelagic regions of all lakes. We conclude (1) that allochthonous OC supported a significant part of total production of new biomass in both pelagic and benthic habitats, (2) that benthic habitats dominated the whole-lake production of new biomass, and (3) that respiration and net CO2 production dominated the carbon flux of the pelagic habitats and biomass production dominated the benthic carbon flux. Taken together, these findings suggest that previous investigations have greatly underestimated the productivity of clear-water lakes when benthic autotrophic production and metabolism of allochthonous OC have not been measured.


Assuntos
Carbono/metabolismo , Ecossistema , Eucariotos/fisiologia , Água Doce/química , Sedimentos Geológicos/química , Microbiologia da Água , Água Doce/microbiologia
8.
Exp Clin Cardiol ; 14(2): 18-20, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19675823

RESUMO

BACKGROUND AND OBJECTIVE: Patients have reported that they perceive their own heart sounds differently after open cardiac surgery than before the surgery. The present study was designed to investigate whether changes in heart sounds can be quantitatively measured. METHOD: Heart sounds were recorded from 57 patients undergoing coronary artery bypass graft (CABG) surgery and from a control group of 10 subjects. The so-called Hjorth descriptors and the main frequency peak were compared before and after surgery to determine whether the characteristics of the heart sounds had changed. RESULTS: At a group level, the first heart sound was found to be significantly different after CABG surgery. Generally, the heart sounds shifted toward a lower frequency after surgery in the CABG group. No significant changes were found in the control group. CONCLUSIONS: Heart sounds are altered after CABG surgery. The changes are objectively quantifiable and may also be subjectively perceived by the patients.

9.
Ultrasound Med Biol ; 35(11): 1892-8, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19713031

RESUMO

Ultrasound Doppler using two-dimensional (2D) techniques is commonly used to study blood flow and myocardial tissue motion. This use includes measurement of velocity and time intervals, often in relation to the electrocardiogram (ECG) signal. 2D Doppler is frequently considered a real-time technique but in reality the acquisition time can be as long as 200 ms per image. We have developed a test-phantom using a rotating cylinder to simulate blood flow and tissue motion in a whole sector or space angle to evaluate velocity and timing characteristics. The phantom can produce constant velocities for velocity testing, as well as accelerating movement for testing the timing characteristics of ultrasound systems. Our investigation shows that the cylinder phantom is especially suitable for timing measurements in 2D Doppler imaging and that time delays between the Doppler signals and the ECG signal exist in the tested ultrasound system.


Assuntos
Modelos Cardiovasculares , Imagens de Fantasmas , Ultrassonografia Doppler em Cores/métodos , Velocidade do Fluxo Sanguíneo , Ecocardiografia Doppler em Cores/métodos , Eletrocardiografia , Desenho de Equipamento , Humanos , Ultrassonografia Doppler de Pulso/métodos
10.
Nature ; 460(7254): 506-9, 2009 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-19626113

RESUMO

Productivity denotes the rate of biomass synthesis in ecosystems and is a fundamental characteristic that frames ecosystem function and management. Limitation of productivity by nutrient availability is an established paradigm for lake ecosystems. Here, we assess the relevance of this paradigm for a majority of the world's small, nutrient-poor lakes, with different concentrations of coloured organic matter. By comparing small unproductive lakes along a water colour gradient, we show that coloured terrestrial organic matter controls the key process for new biomass synthesis (the benthic primary production) through its effects on light attenuation. We also show that this translates into effects on production and biomass of higher trophic levels (benthic invertebrates and fish). These results are inconsistent with the idea that nutrient supply primarily controls lake productivity, and we propose that a large share of the world's unproductive lakes, within natural variations of organic carbon and nutrient input, are limited by light and not by nutrients. We anticipate that our result will have implications for understanding lake ecosystem function and responses to environmental change. Catchment export of coloured organic matter is sensitive to short-term natural variability and long-term, large-scale changes, driven by climate and different anthropogenic influences. Consequently, changes in terrestrial carbon cycling will have pronounced effects on most lake ecosystems by mediating changes in light climate and productivity of lakes.


Assuntos
Ecossistema , Água Doce/química , Luz , Animais , Biomassa , Carbono/análise , Carbono/metabolismo , Eucariotos/fisiologia , Peixes/fisiologia , Nitrogênio/análise , Fósforo/análise , Suécia
11.
Am J Vet Res ; 70(5): 604-13, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19405899

RESUMO

OBJECTIVE: To investigate use of signal analysis of heart sounds and murmurs in assessing severity of mitral valve regurgitation (mitral regurgitation [MR]) in dogs with myxomatous mitral valve disease (MMVD). ANIMALS: 77 client-owned dogs. PROCEDURES: Cardiac sounds were recorded from dogs evaluated by use of auscultatory and echocardiographic classification systems. Signal analysis techniques were developed to extract 7 sound variables (first frequency peak, murmur energy ratio, murmur duration > 200 Hz, sample entropy and first minimum of the auto mutual information function of the murmurs, and energy ratios of the first heart sound [S1] and second heart sound [S2]). RESULTS: Significant associations were detected between severity of MR and all sound variables, except the energy ratio of S1. An increase in severity of MR resulted in greater contribution of higher frequencies, increased signal irregularity, and decreased energy ratio of S2. The optimal combination of variables for distinguishing dogs with high-intensity murmurs from other dogs was energy ratio of S2 and murmur duration > 200 Hz (sensitivity, 79%; specificity, 71%) by use of the auscultatory classification. By use of the echocardiographic classification, corresponding variables were auto mutual information, first frequency peak, and energy ratio of S2 (sensitivity, 88%; specificity, 82%). CONCLUSIONS AND CLINICAL RELEVANCE: Most of the investigated sound variables were significantly associated with severity of MR, which indicated a powerful diagnostic potential for monitoring MMVD. Signal analysis techniques could be valuable for clinicians when performing risk assessment or determining whether special care and more extensive examinations are required.


Assuntos
Doenças do Cão/diagnóstico , Sopros Cardíacos/veterinária , Ruídos Cardíacos/fisiologia , Insuficiência da Valva Mitral/veterinária , Animais , Análise Discriminante , Cães , Ecocardiografia/veterinária , Feminino , Sopros Cardíacos/diagnóstico , Masculino , Valva Mitral/patologia , Insuficiência da Valva Mitral/diagnóstico , Análise de Regressão , Sensibilidade e Especificidade , Índice de Gravidade de Doença
12.
Ultrasound Med Biol ; 35(3): 447-57, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19152997

RESUMO

Quantitative assessment of regional myocardial function at rest and during stress with Doppler tissue imaging (DTI) plays an important role in daily routine echocardiography. However, reliable visual analysis is largely dependent on image quality and adequate border delineation, which still remains a challenge in a significant number of patients. In this respect, an ultrasound contrast agent (UCA) is often used to improve visualization in patients with suboptimal image quality. The knowledge of how DTI measurements will be affected by UCA present in the tissue is therefore of significant importance for an accurate interpretation of local myocardial motion. The aim of this paper was to investigate how signal contribution from UCA and nonlinear wave propagation influence the performance of the autocorrelation phase shift estimator used for DTI applications. Our results are based on model experiments with a clinical 2-D grayscale scanner and computational simulations of the DTI velocity estimator for synthetically-derived pulses, simulated bubble echoes and experimentally-sampled RF data of transmitted pulses and backscattered contrast echoes. The results show that destruction of UCA present in the tissue will give rise to an apparent bidirectional velocity bias of individual velocity estimates, but that spatial averaging of individual velocity measurements within a region-of-interest will result in a negative bias (away from the transducer) of the estimated mean or mean peak velocity. The UCA destruction will also have a significant impact on the measured integrated mean velocity over time, i.e., displacement. To achieve improved visualization with UCA during DTI-examinations, we either recommend that it is performed at low acoustic powers, mechanical index

Assuntos
Meios de Contraste , Ecocardiografia Doppler/métodos , Ecocardiografia sob Estresse/métodos , Velocidade do Fluxo Sanguíneo , Simulação por Computador , Compostos Férricos , Coração/fisiologia , Humanos , Ferro , Microbolhas , Modelos Cardiovasculares , Óxidos
13.
Artigo em Inglês | MEDLINE | ID: mdl-18003315

RESUMO

In this study we aim to explain the behavior of textile electrodes due to their construction techniques. Three textile electrodes were tested for electrode impedance and polarization potentials. The multifilament yarn (A) is favorable for its low thread resistance. Although, when knitted into electrodes, the staple fiber yarn (B) showed a comparable and satisfiable electrode impedance. The multifilament yarn had however a lower polarization potential drift then the other specimens. The monofilament yarn (C) had high electrode impedance and varying mean polarization potentials due to its conductive material and small contact area with the skin.


Assuntos
Vestuário , Eletrodos , Monitorização Ambulatorial/instrumentação , Têxteis , Condutividade Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Materiais , Monitorização Ambulatorial/métodos
14.
Artigo em Inglês | MEDLINE | ID: mdl-18002364

RESUMO

Mild sclerotic thickening of the aortic valve affects 25% of the population, and the condition causes aortic valve stenosis (AS) in 2% of adults above 65 years. Echocardiography is today the clinical standard for assessing AS. However, a cost effective and uncomplicated technique that can be used for decision support in the primary health care would be of great value. In this study, recorded phonocardiographic signals were analyzed using the first local minimum of the auto mutual information (AMI) function. The AMI method measures the complexity in the sound signal, which is related to the amount of turbulence in the blood flow and thus to the severity of the stenosis. Two previously developed phonocardiographic methods for assessing AS severity were used for comparison, the murmur energy ratio and the sound spectral averaging technique. Twenty-nine patients with suspected AS were examined with Doppler echocardiography. The aortic jet velocity was used as a reference of AS severity, and it was found to correlate with the AMI method, the murmur energy ratio and the sound spectral averaging technique with the correlation coefficient R = 0.82, R = 0.73 and R = 0.76, respectively.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/patologia , Sopros Cardíacos/diagnóstico , Fonocardiografia/instrumentação , Processamento de Sinais Assistido por Computador , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica , Velocidade do Fluxo Sanguíneo , Análise Custo-Benefício , Feminino , Auscultação Cardíaca , Sopros Cardíacos/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Fonocardiografia/métodos
15.
Med Biol Eng Comput ; 45(12): 1251-7, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17929069

RESUMO

Clothing with conductive textiles for health care applications has in the last decade been of an upcoming research interest. An advantage with the technique is its suitability in distributed and home health care. The present study investigates the electrical properties of conductive yarns and textile electrodes in contact with human skin, thus representing a real ECG-registration situation. The yarn measurements showed a pure resistive characteristic proportional to the length. The electrodes made of pure stainless steel (electrode A) and 20% stainless steel/80% polyester (electrode B) showed acceptable stability of electrode potentials, the stability of A was better than that of B. The electrode made of silver plated copper (electrode C) was less stable. The electrode impedance was lower for electrodes A and B than that for electrode C. From an electrical properties point of view we recommend to use electrodes of type A to be used in intelligent textile medical applications.


Assuntos
Microeletrodos , Telemetria/instrumentação , Têxteis , Engenharia Biomédica , Vestuário , Cobre , Condutividade Elétrica , Impedância Elétrica , Humanos , Poliésteres , Prata , Aço Inoxidável
16.
Am J Vet Res ; 68(9): 962-9, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17764410

RESUMO

OBJECTIVE: To investigate whether time-frequency and complexity analyses of heart murmurs can be used to differentiate physiologic murmurs from murmurs caused by aortic stenosis (AS) in Boxers. ANIMALS: 27 Boxers with murmurs. PROCEDURES: Dogs were evaluated via auscultation and echocardiography. Analyses of time-frequency properties (TFPs; ie, maximal murmur frequency and duration of murmur frequency > 200 Hz) and correlation dimension (T(2)) of murmurs were performed on phonocardiographic sound data. Time-frequency property and T(2) analyses of low-intensity murmurs in 16 dogs without AS were performed at 7 weeks and 12 months of age. Additionally, TFP and T(2) analyses were performed on data obtained from 11 adult AS-affected dogs with murmurs. RESULTS: In dogs with low-intensity murmurs, TFP or T(2) values at 7 weeks and 12 months did not differ significantly. For differentiation of physiologic murmurs from murmurs caused by mild AS, duration of murmur frequency > 200 Hz was useful and the combination assessment of duration of frequency > 200 Hz and T(2) of the murmur had a sensitivity of 94% and a specificity of 82%. Maximal murmur frequency did not differentiate dogs with AS from those without AS. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggested that assessment of the duration of murmur frequency > 200 Hz can be used to distinguish physiologic heart murmurs from murmurs caused by mild AS in Boxers. Combination of this analysis with T(2) analysis may be a useful complementary method for diagnostic assessment of cardiovascular function in dogs.


Assuntos
Estenose da Valva Aórtica/veterinária , Doenças do Cão/fisiopatologia , Sopros Cardíacos/veterinária , Animais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Interpretação Estatística de Dados , Doenças do Cão/diagnóstico , Doenças do Cão/diagnóstico por imagem , Cães , Ecocardiografia Doppler em Cores/veterinária , Feminino , Auscultação Cardíaca/veterinária , Sopros Cardíacos/diagnóstico , Sopros Cardíacos/diagnóstico por imagem , Sopros Cardíacos/fisiopatologia , Masculino
17.
Ann Biomed Eng ; 34(11): 1666-77, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17019618

RESUMO

Heart murmurs are often the first signs of pathological changes of the heart valves, and they are usually found during auscultation in the primary health care. Distinguishing a pathological murmur from a physiological murmur is however difficult, why an "intelligent stethoscope" with decision support abilities would be of great value. Phonocardiographic signals were acquired from 36 patients with aortic valve stenosis, mitral insufficiency or physiological murmurs, and the data were analyzed with the aim to find a suitable feature subset for automatic classification of heart murmurs. Techniques such as Shannon energy, wavelets, fractal dimensions and recurrence quantification analysis were used to extract 207 features. 157 of these features have not previously been used in heart murmur classification. A multi-domain subset consisting of 14, both old and new, features was derived using Pudil's sequential floating forward selection (SFFS) method. This subset was compared with several single domain feature sets. Using neural network classification, the selected multi-domain subset gave the best results; 86% correct classifications compared to 68% for the first runner-up. In conclusion, the derived feature set was superior to the comparative sets, and seems rather robust to noisy data.


Assuntos
Algoritmos , Inteligência Artificial , Diagnóstico por Computador/métodos , Auscultação Cardíaca/métodos , Sopros Cardíacos/diagnóstico , Reconhecimento Automatizado de Padrão/métodos , Espectrografia do Som/métodos , Idoso , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
J Am Soc Echocardiogr ; 19(2): 154-64, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16455419

RESUMO

The combination of Doppler tissue imaging and myocardial contrast echocardiography has the potential to provide information about motion and perfusion of the myocardium in a single examination. The purpose of this study was to establish how the presence of ultrasound contrast agent (UCA) affects measurements of Doppler tissue velocities in vivo and in vitro. We performed echocardiography in 12 patients with ischemic heart disease before and immediately after a slow intravenous infusion of the UCA Optison, using color Doppler tissue imaging to examine the effect of contrast agents in vivo. The myocardial peak systolic velocities and their integrals were analyzed in digitally stored cineloops before and after contrast administration. To distinguish between methodologic and physiologic factors affecting the measurement of tissue velocity in vitro, experiments with a rotating disk and a flow cone phantom were also carried out for the 3 contrast agents: Optison, Sonovue, and Sonazoid. In vivo results show that the values for peak systolic velocity increased by about 10% during contrast infusion, from mean 5.2 +/- 1.8 to 5.7 +/- 2.3 cm/s (P = .02, 95% confidence interval 2%-16%). The increase in myocardial peak systolic velocities was verified in experimental models in which the UCA increased the estimated mean velocity in the order of 5% to 20% for the motion interval of 5 to 7 cm/s, corresponding to the myocardial velocities studied in vivo. The response was similar for all 3 contrast agents and was not affected by moderate variations in concentration of the agent. We have shown that the presence UCA will affect Doppler tissue measurements in vivo and in vitro. The observed bias is presumed to be an effect of harmonic signal contribution from rupturing contrast agent microbubbles and does not indicate biologic or physiologic effects.


Assuntos
Albuminas , Ecocardiografia/métodos , Compostos Férricos , Fluorocarbonos , Ferro , Isquemia Miocárdica/diagnóstico por imagem , Óxidos , Fosfolipídeos , Volume Sistólico , Hexafluoreto de Enxofre , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Movimento , Infarto do Miocárdio , Isquemia Miocárdica/complicações , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/etiologia
19.
J Artif Organs ; 8(3): 192-7, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16235036

RESUMO

Severe blood pressure changes are well known in hemodialysis. Detection and prediction of these are important for the well-being of the patient and for optimizing treatment. New noninvasive methods for this purpose are required. The pulse wave transit time technique is an indirect estimation of blood pressure, and our intention is to investigate whether this technique is applicable for hemodialysis treatment. A measurement setup utilizing lower body negative pressure and isometric contraction was used to simulate dialysis-related blood pressure changes in normal test subjects. Systolic blood pressure levels were compared to different pulse wave transit times, including and excluding the cardiac preejection period. Based on the results of these investigations, a pulse wave transit time technique adapted for dialysis treatment was developed and tried out on patients. To determine systolic blood pressure in the normal group, the total pulse wave transit time was found most suitable (including the cardiac preejection period). Correlation coefficients were r = 0.80 +/- 0.06 (mean +/- SD) overall and r = 0.81 +/- 0.16 and r = 0.09 +/- 0.62 for the hypotension and hypertension phases, respectively. When applying the adapted technique in dialysis patients, large blood pressure variations could easily be detected when present. Pulse wave transit time is correlated to systolic blood pressure within the acceptable range for a trend-indicating system. The method's applicability for dialysis treatment requires further studies. The results indicate that large sudden pressure drops, like those seen in sudden hypovolemia, can be detected.


Assuntos
Determinação da Pressão Arterial/métodos , Pressão Sanguínea , Monitorização Fisiológica , Pulso Arterial , Diálise Renal , Adulto , Idoso , Feminino , Humanos , Masculino
20.
Ultrasonics ; 42(1-9): 301-7, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15047302

RESUMO

The propagation of diagnostic ultrasonic imaging pulses in tissue and their interaction with contrast micro bubbles is a very complex physical process, which we assumed to be separable into three stages: pulse propagation in tissue, the interaction of the pulse with the contrast bubble, and the propagation of the scattered echo. The model driven approach is used to gain better knowledge of the complex processes involved. A simplified way of field simulation is chosen due to the complexity of the task and the necessity to estimate comparative contributions of each component of the process. Simulations are targeted at myocardial perfusion estimation. A modified method for spatial superposition of attenuated waves enables simulations of low intensity pulse pressure fields from weakly focused transducers in a nonlinear, attenuating, and liquid-like biological medium. These assumptions enable the use of quasi-linear calculations of the acoustic field. The simulations of acoustic bubble response are carried out with the Rayleigh-Plesset equation with the addition of radiation damping. Theoretical simulations with synthesised and experimentally sampled pulses show that the interaction of the excitation pulses with the contrast bubbles is the main cause of nonlinear scattering, and a 2-3 dB increase of second harmonic amplitude depends on nonlinear distortions of the incident pulse.


Assuntos
Meios de Contraste , Ecocardiografia , Microesferas , Modelos Teóricos , Processamento de Sinais Assistido por Computador , Transdutores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...