Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 152: 18-24, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31279149

RESUMO

In this study, Nerium oleander L. leaves were used as biomonitors to evaluate environmental pollutants levels in a sub-region in the Metropolitan Area of Rio de Janeiro City (Brazil) through X-ray Fluorescence (XRF). Control samples were collected in a rural zone next to the Parque Estadual da Pedra Branca/RJ. The samples were collected during all seasons of 2015 (summer, fall, winter and spring). The concentration of 13 elements (S, Cl, K, Ca, Mn, Fe, Cu, Zn, Br, Rb, Sr, Ba and Pb) was determined. Most of the elements showed, during all seasons, median concentrations of sampling sites higher than the results obtained from the control sites. The principal component analysis (PCA) showed the grouping of the elements in two main factors that can be associated to emission sources of these elements. The elements Cl, K, Ca, Cu, Rb and Sr can be associated as a possible influence from the soil (root uptake and/or resuspension). On the other hand, the elements Fe, Cu, Zn, and Pb can be associated to vehicle and industry emission sources. The study showed that the XRF technique applied to Nerium oleander L. leaves is efficient to environmental pollution analysis in Metropolitan Regions since it is precise, fast and low-cost, besides allowing the monitoring of pollution levels over time.


Assuntos
Poluição do Ar/análise , Metais Pesados/análise , Nerium/química , Folhas de Planta/química , Brasil , Cidades , Monitoramento Ambiental/métodos , Espectrometria por Raios X
2.
Appl Spectrosc ; 71(3): 432-437, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27694429

RESUMO

In this study, we investigate the capability of energy dispersive X-ray fluorescence (EDXF) spectrometry in a triaxial geometry apparatus as a fast and nondestructive determination method of both dominant and contaminant elements in pharmaceutical iron supplements. The following iron supplements brands with their respective active ingredients were analyzed: Neutrofer fólico (iron gylcinate), Anemifer (iron(II) sulfate monohydrate), Noripurum (iron(III)-hydroxide polymaltose complex), Sulferbel (iron(II) sulfate monohydrate), and Combiron Fólico (carbonyl iron). Although we observe a good agreement between the iron content obtained by the present method and that indicated in the supplement's prescribed dose, we observe contamination by manganese and nickel of up to 180 µg and 36 µg, respectively. These contents correspond to 7.2% and 14.4% of the permitted daily exposure of manganese and nickel, respectively, for an average adult individual as determined by the European Medicine Agency (EMEA). The method was successfully validated against the concentrations of several certified reference materials of biological light matrices with similar concentrations of contaminants. Moreover, we also validated our method by comparing the concentrations with those obtained with the inductively coupled plasma-atomic emission technique.

3.
Caries Res ; 49(2): 99-108, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25572115

RESUMO

This in vivo study aimed to evaluate the influence of contact points on the approximal caries detection in primary molars, by comparing the performance of the DIAGNOdent pen and visual-tactile examination after tooth separation to bitewing radiography (BW). A total of 112 children were examined and 33 children were selected. In three periods (a, b, and c), 209 approximal surfaces were examined: (a) examiner 1 performed visual-tactile examination using the Nyvad criteria (EX1); examiner 2 used DIAGNOdent pen (LF1) and took BW; (b) 1 week later, after tooth separation, examiner 1 performed the second visual-tactile examination (EX2) and examiner 2 used DIAGNOdent again (LF2); (c) after tooth exfoliation, surfaces were directly examined using DIAGNOdent (LF3). Teeth were examined by computed microtomography as a reference standard. Analyses were based on diagnostic thresholds: D1: D 0 = health, D 1 ­D 4 = disease; D2: D 0 , D 1 = health, D 2 ­D 4 = disease; D3: D 0 ­D 2 = health, D 3 , D 4 = disease. At D1, the highest sensitivity/specificity were observed for EX1 (1.00)/LF3 (0.68), respectively. At D2, the highest sensitivity/ specificity were observed for LF3 (0.69)/BW (1.00), respectively. At D3, the highest sensitivity/specificity were observed for LF3 (0.78)/EX1, EX2 and BW (1.00). EX1 showed higher accuracy values than LF1, and EX2 showed similar values to LF2. We concluded that the visual-tactile examination showed better results in detecting sound surfaces and approximal caries lesions without tooth separation. However, the effectiveness of approximal caries lesion detection of both methods was increased by the absence of contact points. Therefore, regardless of the method of detection, orthodontic separating elastics should be used as a complementary tool for the diagnosis of approximal noncavitated lesions in primary molars.


Assuntos
Cárie Dentária/diagnóstico , Dente Molar/patologia , Coroa do Dente/patologia , Dente Decíduo/patologia , Criança , Cárie Dentária/diagnóstico por imagem , Esmalte Dentário/diagnóstico por imagem , Esmalte Dentário/patologia , Dentina/diagnóstico por imagem , Dentina/patologia , Humanos , Lasers , Dente Molar/diagnóstico por imagem , Exame Físico/estatística & dados numéricos , Radiografia Interproximal/estatística & dados numéricos , Sensibilidade e Especificidade , Coroa do Dente/diagnóstico por imagem , Esfoliação de Dente/diagnóstico por imagem , Esfoliação de Dente/patologia , Dente Decíduo/diagnóstico por imagem , Percepção do Tato/fisiologia , Percepção Visual/fisiologia , Microtomografia por Raio-X/estatística & dados numéricos
4.
Appl Radiat Isot ; 68(4-5): 948-50, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19959370

RESUMO

Proton computerized tomography deals with relatively thick targets like the human head or trunk. In this case precise analytical calculation of the proton final energy is a rather complicated task, thus the Monte Carlo simulation stands out as a solution. We used the GEANT4.8.2 code to calculate the proton final energy spectra after passing a thick Al absorber and compared it with the same conditions of the experimental data. The ICRU49, Ziegler85 and Ziegler2000 models from the low energy extension pack were used. The results were also compared with the SRIM2008 and MCNPX2.4 simulations, and with solutions of the Boltzmann transport equation in the Fokker-Planck approximation.


Assuntos
Alumínio/química , Modelos Estatísticos , Validação de Programas de Computador , Software , Tomografia Computadorizada por Raios X/métodos , Simulação por Computador , Prótons , Doses de Radiação , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
5.
Appl Radiat Isot ; 68(4-5): 951-3, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19932624

RESUMO

This work presents the recent results of computer simulations for the low energy proton beam tomographic scanner installed at the cyclotron CV-28 of IEN/CNEN. New computer simulations were performed in order to adjust the parameters of previous simulation within the first experimental results and to understand some specific effects that affected the form of the final proton energy spectra. To do this, the energy and angular spread of the initial proton beam were added, and the virtual phantom geometry was specified more accurately in relation to the real one. As a result, a more realistic view on the measurements was achieved.


Assuntos
Alumínio/química , Modelos Estatísticos , Validação de Programas de Computador , Software , Tomografia Computadorizada por Raios X/métodos , Simulação por Computador , Prótons , Doses de Radiação , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...