Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Cureus ; 14(9): e28737, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36211092

RESUMO

Ulnar nerve dysfunction following distal humerus fractures is a recognized phenomenon. There is no dominating consensus regarding the optimal management of the ulnar nerve during surgical intervention for these fractures between leaving the nerve in situ versus nerve transposition for better healing. Additional complexities arise in the case we present, in which there was an open fracture compounded with an ulnar nerve laceration from a traumatic injury with a machete knife. We review and discuss the management of ulnar nerve injuries associated with complex open fractures of the humerus for optimizing patient outcomes following these injuries.

2.
J Orthop Trauma ; 35(12): 626-631, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34797781

RESUMO

OBJECTIVES: To determine whether skin perfusion surrounding tibial plateau and pilon fractures is associated with the Tscherne classification for severity of soft tissue injury. The secondary aim was to determine if soft tissue perfusion improves from the time of injury to the time of definitive fracture fixation in fractures treated using a staged protocol. DESIGN: Prospective cohort study. SETTING: Academic trauma center. PATIENTS: Eight pilon fracture patients and 19 tibial plateau fracture patients who underwent open reduction internal fixation. MAIN OUTCOME MEASURES: Skin perfusion (fluorescence units) as measured by LA-ICGA. RESULTS: Six patients were classified as Tscherne grade 0, 9 as grade 1, 10 as grade 2, and 2 as grade 3. Perfusion decreased by 14 fluorescence units (95% confidence interval, -21 to -6; P < 0.01) with each increase in Tscherne grade. Sixteen patients underwent staged fixation with an external fixator (mean time to definitive fixation 14.1 days). The mean perfusion increased significantly at the time of definitive fixation by a mean of 13.9 fluorescence units (95% confidence interval 4.8-22.9; P = 0.01). CONCLUSIONS: LA-ICGA perfusion measures are associated with severity of soft tissue injury surrounding orthopaedic trauma fractures and appear to improve over time when fractures are stabilized in an external fixator. Further research is warranted to investigate whether objective perfusion measures are predictive of postoperative wound healing complications and whether this tool can be used to effectively guide timing of safe surgical fixation. LEVEL OF EVIDENCE: Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Fixação Interna de Fraturas , Fraturas da Tíbia , Angiografia , Fixadores Externos , Humanos , Lasers , Perfusão , Projetos Piloto , Estudos Prospectivos , Estudos Retrospectivos , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Resultado do Tratamento
3.
Health Econ Rev ; 11(1): 15, 2021 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-33903947

RESUMO

BACKGROUND: Smoking increases the risk of complications and related costs after an orthopaedic fracture. Research in other populations suggests that a one-time payment may incentivize smoking cessation. However, little is known on fracture patients' willingness to accept financial incentives to stop smoking; and the level of incentive required to motivate smoking cessation in this population. This study aimed to estimate the financial threshold required to motivate fracture patients to stop smoking after injury. METHODS: This cross-sectional study utilized a discrete choice experiment (DCE) to elicit patient preferences towards financial incentives and reduced complications associated with smoking cessation. We presented participants with 12 hypothetical options with several attributes with varying levels. The respondents' data was used to determine the utility of each attribute level and the relative importance associated with each attribute. RESULTS: Of the 130 enrolled patients, 79% reported an interest in quitting smoking. We estimated the financial incentive to be of greater relative importance (ri) (45%) than any of the included clinical benefits of smoking cessations (deep infection (ri: 24%), bone healing complications (ri: 19%), and superficial infections (ri: 12%)). A one-time payment of $800 provided the greatest utility to the respondents (0.64, 95% CI: 0.36 to 0.93), surpassing the utility associated with a single $1000 financial incentive (0.36, 95% CI: 0.18 to 0.55). CONCLUSIONS: Financial incentives may be an effective tool to promote smoking cessation in the orthopaedic trauma population. The findings of this study define optimal payment thresholds for smoking cessation programs.

4.
Injury ; 52(8): 2395-2402, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33712297

RESUMO

INTRODUCTION: The purpose of our study was to evaluate the factors that influence the timing of definitive fixation in the management of bilateral femoral shaft fractures and the outcomes for patients with these injuries. METHODS: Patients with bilateral femur fractures treated between 1998 to 2019 at ten level-1 trauma centers were retrospectively reviewed. Patients were grouped into early or delayed fixation, which was defined as definitive fixation of both femurs within or greater than 24 hours from injury, respectively. Statistical analysis included reversed logistic odds regression to predict which variable(s) was most likely to determine timing to definitive fixation. The outcomes included age, sex, high-volume institution, ISS, GCS, admission lactate, and admission base deficit. RESULTS: Three hundred twenty-eight patients were included; 164 patients were included in the early fixation group and 164 patients in the delayed fixation group. Patients managed with delayed fixation had a higher Injury Severity Score (26.8 vs 22.4; p<0.01), higher admission lactate (4.4 and 3.0; p<0.01), and a lower Glasgow Coma Scale (10.7 vs 13; p<0.01). High-volume institution was the most reliable influencer for time to definitive fixation, successfully determining 78.6% of patients, followed by admission lactate, 64.4%. When all variables were evaluated in conjunction, high-volume institution remained the strongest contributor (X2 statistic: institution: 45.6, ISS: 8.83, lactate: 6.77, GCS: 0.94). CONCLUSION: In this study, high-volume institution was the strongest predictor of timing to definitive fixation in patients with bilateral femur fractures. This study demonstrates an opportunity to create a standardized care pathway for patients with these injuries. LEVEL OF EVIDENCE: Level III.


Assuntos
Fraturas do Fêmur , Traumatismo Múltiplo , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Fêmur , Humanos , Escala de Gravidade do Ferimento , Estudos Retrospectivos , Centros de Traumatologia
5.
J Orthop Trauma ; 35(9): 499-504, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-33512861

RESUMO

OBJECTIVE: To evaluate rates of complications in patients with bilateral femur fractures treated with intramedullary nailing (IMN) during either 1 single procedure or 2 separate procedures. DESIGN: A multicenter retrospective review of patients sustaining bilateral femur fractures, treated with IMN in single or 2-stage procedure, from 1998 to 2018 was performed at 10 Level-1 trauma centers. SETTING: Ten Level-1 trauma centers. PATIENTS/PARTICIPANTS: Two hundred forty-six patients with bilateral femur fractures. INTERVENTIONS: Intramedullary nailing. MAIN OUTCOME MEASURES: Incidence of complications. RESULTS: A total of 246 patients were included, with 188 single-stage and 58 two-stage patients. Gender, age, injury severity score, abbreviated injury score, secondary injuries, Glasgow coma scale, and proportion of open fractures were similar between both groups. Acute respiratory distress syndrome (ARDS) occurred at higher rates in the 2-stage group (13.8% vs. 5.9%; P value = 0.05). When further adjusted for age, gender, injury severity score, abbreviated injury score, Glasgow coma scale, and admission lactate, the single-stage group had a 78% reduced risk for ARDS. In-hospital mortality was higher in the single-stage cohort (2.7% compared with 0%), although this did not meet statistical significance (P = 0.22). CONCLUSIONS: This is the largest multicenter study to date evaluating the outcomes between single- and 2-stage IMN fixation for bilateral femoral shaft fractures. Single-stage bilateral femur IMN may decrease rates of ARDS in polytrauma patients who are able to undergo simultaneous definitive fixation. However, a future prospective study with standardized protocols in place will be required to discern whether single- versus 2-stage fixation has an effect on mortality and to identify those individuals at risk. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Fêmur , Fixação Intramedular de Fraturas/efeitos adversos , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento
6.
J Orthop Trauma ; 35(1): e18-e24, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32833697

RESUMO

OBJECTIVE: To determine whether fully threaded transiliac-transsacral (TI-TS) fixation is biomechanically superior to partially threaded TI-TS fixation of vertically unstable transforaminal sacral fractures. METHODS: Vertically unstable zone 2 sacral fractures were created in 20 human cadaveric pelves with a unilateral osteotomy and resection of 1 cm of bone through the foramen of the sacrum to represent comminution. Ten specimens received either 2 7.3-mm fully threaded or 2 7.3-mm partially threaded TI-TS screw fixation at the S1 and S2 body, and every specimen received standard 3.5-mm 8-hole parasymphyseal plating anteriorly. Each pelvis was loaded to 250 N at 3 Hz for 100,000 cycles and then loaded to failure. The primary outcome was fracture displacement at the S1 foramen, which was measured at 25,000, 50,000, 75,000, and 100,000 cycles. Secondary outcomes were simulated clinical failure of ≥1 cm displacement at the S1 foramen to determine occurrence probability of failure, and load at failure was defined as 2.5 cm of the linear loading system displacement. Specimens in the fully threaded and partially threaded cohorts were otherwise respectively comparable in regards to age, gender, and bone density. RESULTS: Five of the 10 TI-TS partially threaded specimens experienced simulated clinical failure with >1 cm displacement at the S1 foramen compared with 0 of the 10 TI-TS fully threaded cohort (50% vs. 0%, P = 0.03). The mean maximal displacement at the S1 foramen was greater in the partially threaded cohort (9.3 mm) compared with the fully threaded cohort (3.6 mm; P = 0.004). Fully threaded specimens also demonstrated greater mean force to failure than the partially threaded specimens (461 N vs. 288 N; P = 0.0001). CONCLUSIONS: Fully threaded TI-TS screw fixation seems to be mechanically superior to partially threaded fixation in a cadaveric vertically unstable transforaminal sacral fracture model with significantly less displacement of the posterior pelvic ring and greater load to failure.


Assuntos
Fraturas Ósseas , Ossos Pélvicos , Fenômenos Biomecânicos , Parafusos Ósseos , Cadáver , Fixação Interna de Fraturas , Fraturas Ósseas/cirurgia , Humanos , Ossos Pélvicos/cirurgia , Sacro/cirurgia
7.
J Orthop Trauma ; 35(2): 100-105, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32658018

RESUMO

OBJECTIVES: To determine the association between displaced femoral shaft bone fragments ("spikes") seen on radiographs after intramedullary nail insertion and the need for future motion surgery. DESIGN: Retrospective case-control study. SETTING: Academic trauma center. PATIENTS: We included patients with femoral shaft fractures treated with intramedullary nail insertion. Case patients (n = 22) had developed knee stiffness treated with motion surgery. The control group was a randomly selected sample (1:3 ratio). MAIN OUTCOME MEASURES: Motion surgery to address knee stiffness. We defined a "spike distance ratio" and "spike area ratio" from initial postoperative anteroposterior and lateral radiographs. Multivariable logistic regression determined the effect of spike distance and area ratios on the likelihood of need for motion surgery, controlling for polytraumatic injuries and bilateral fractures. RESULTS: The case group had a median femoral spike distance ratio of 1.9 [interquartile range (IQR), 1.6-2.5] compared with 1.5 (IQR, 1.2-1.8) in the control group. An increased femoral spike distance ratio was associated with increased odds of motion surgery (P < 0.01). A femoral spike distance >2 times the femoral radius had 32 times the odds (95% confidence interval, 2-752) of motion surgery compared with patients with distance ratios <1.25. Median femoral spike area ratios were similar between the case (0.2; IQR, 0.1-0.5) and control (0.2; IQR, 0.0-0.5) groups and were not associated with increased odds of motion surgery (P = 0.34). CONCLUSIONS: A larger spike distance ratio is associated with increased odds of subsequent motion surgery. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Pinos Ortopédicos , Estudos de Casos e Controles , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas/efeitos adversos , Humanos , Estudos Retrospectivos , Resultado do Tratamento
8.
Injury ; 51(7): 1662-1668, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32434717

RESUMO

INTRODUCTION: We assessed the outcome and safety of posterior plating of distal tibial fractures. METHODS: We conducted a retrospective case series at a Level I trauma center. Seventy-four consecutive patients with distal tibial fractures treated with anatomically contoured 3.5-mm T-shaped locking compression plate using a posterolateral approach from January 2008 through April 2018 were included in the study. The mean patient age was 48 years (range, 18-87 years). Fifty-nine percent of the patients were male patients, 47% of the fractures were open fractures; and 27% of the patients had multiple traumatic injuries. Eleven fractures were AO/OTA type 42, 22 were type 43A, and 41 were type 43C. Sixty-two (84%) patients were treated with initial spanning external fixation (median time, 23 days) and staged open reduction and internal fixation. The main outcome measure was unplanned reoperation to address implant failure, nonunion, deep surgical site infection, or symptomatic implant. RESULTS: Overall risk of unplanned reoperation was 15% (11 of 74 patients, 95% confidence interval, 9%-25%). Four (5%) reoperations were for nonunion, three (4%) were for surgical site infection, two (3%) were for infected nonunion, and two (3%) were for implant prominence. Loss of alignment >10 degrees occurred in one patient who underwent unplanned reoperation for nonunion. No plate breakage occurred. Median time to reoperation was 221 days (range, 22-436 days). Only one other complication was noted: wound dehiscence associated with the posterolateral approach, which was treated with irrigation and débridement and a 6-week regimen of oral antibiotics. CONCLUSIONS: Use of a posterolateral approach with a pre-contoured locking compression T-plate for the treatment of distal tibial fractures led to reasonable outcomes with an acceptable risk of unplanned reoperation, even with a high proportion of open fractures commonly staged with external fixation.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/métodos , Fraturas Expostas/cirurgia , Infecção da Ferida Cirúrgica/prevenção & controle , Fraturas da Tíbia/cirurgia , Adulto , Traumatismos do Tornozelo/diagnóstico por imagem , Traumatismos do Tornozelo/cirurgia , Fixadores Externos , Feminino , Fixação Interna de Fraturas/instrumentação , Consolidação da Fratura , Fraturas Expostas/diagnóstico por imagem , Fraturas não Consolidadas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Amplitude de Movimento Articular , Reoperação , Estudos Retrospectivos , Fraturas da Tíbia/diagnóstico por imagem
9.
Drug Alcohol Depend ; 153: 201-6, 2015 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-26051158

RESUMO

BACKGROUND: Deceptive methods of falsifying urine samples are of concern for anyone who relies on accurate urine toxicology results. A novel method to combat these efforts utilizes polyethylene glycol (PEG) markers administered orally prior to providing a urine sample. By using various PEG combinations to create a tracer capsule of unique composition, each urine sample can be matched to that individual. The goal of this study was to determine the effectiveness of using the PEG marker system among active heroin users screening for research studies. METHODS: Upon each screening visit, participants (N=55) were randomized to provide an unobserved urine sample, or the PEG tracer procedure was used. LCMS analysis was used to distinguish the PEG combinations, and allowed us to provide a unique qualitative analysis of patterns of drug use (N=168, total urine specimens). RESULTS: The unique composition of the tracer capsules was accurately detected in 83.5% of the urine specimens. Analyses of inconsistencies implicated a number of possible attempts at fraudulence (11.4%) and investigator/lab error (5.1%). Among this sample, the concurrent use of multiple classes of psychoactive drugs was more common than not, though concomitant drug use was often underreported. CONCLUSION: Urine drug testing should be the minimum standard for obtaining information about drug use as self-report was unreliable even in a situation where there were no perceived adverse consequences for full disclosure. In cases where there are significant pressures for individuals to falsify these data, more protective collection methods such as the PEG marker system should be considered.


Assuntos
Biomarcadores/urina , Fraude/prevenção & controle , Dependência de Heroína/urina , Polietilenoglicóis/administração & dosagem , Detecção do Abuso de Substâncias/métodos , Feminino , Humanos , Masculino , Polietilenoglicóis/análise , Detecção do Abuso de Substâncias/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...