Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nepal Med Coll J ; 12(2): 66-8, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21222398

RESUMO

Fracture of the penis is rupture of the tunica albuginea and the usual cause is abrupt bending of the erect penis by blunt trauma. Trauma during sexual relation is responsible for approximately one third of all cases. The incidence of urethral injuries associated with this condition ranged from 2.0% to 38.0%. Twelve patients who presented to emergency over a period of 4 years with diagnosis of penile fracture were reviewed retrospectively. Patient's profile and all relevant data were noted from charts. The etiology of fracture was related to coital activity in 6 (50.0%) cases while other denied such act. Surgery was performed on all the patients and discharged from hospital on removal of urethral catheter. Follow up continued until restoration of normal penile function without complaint. So fracture of the penis is an injury that can be diagnosed clinically and needs emergency surgical correction for better result.


Assuntos
Pênis/lesões , Adulto , Hospitais de Ensino , Humanos , Masculino , Pênis/cirurgia , Estudos Retrospectivos , Ruptura , Ferimentos e Lesões/diagnóstico , Ferimentos e Lesões/cirurgia
2.
Eur J Prosthodont Restor Dent ; 17(2): 58-60, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19645305

RESUMO

Traditionally long curing cycles have been recommended for heat cured acrylic resin denture base materials. Recently manufacturers have produced materials for which they recommend short curing cycles. Specimens conforming to British Standards Specification were made using three different brands of heat cured acrylic resin denture base material. Each material was processed in three batches using either the manufacturer's recommended short curing cycle, an arbitrary medium curing cycle or a traditional long cycle. Specimens were subjected to a three point bending test. With one exception using the arbitrary medium curing cycle, all specimens achieved the British Standard suggesting that the manufacturers' recommended cycles should be followed.


Assuntos
Resinas Acrílicas , Bases de Dentadura , Resinas Acrílicas/normas , Análise do Estresse Dentário , Módulo de Elasticidade , Dureza , Temperatura Alta , Transição de Fase , Maleabilidade , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...