Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Diagn Lab Immunol ; 8(3): 560-3, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11329458

RESUMO

Normal assay variation associated with bDNA tests for human immunodeficiency virus type 1 (HIV-1) RNA performed at two laboratories with different levels of test experience was investigated. Two 5-ml aliquots of blood in EDTA tubes were collected from each patient for whom the HIV-1 bDNA test was ordered. Blood was stored for no more than 4 h at room temperature prior to plasma separation. Plasma was stored at -70 degrees C until transported to the Central Pennsylvania Alliance Laboratory (CPAL; York, Pa.) and to the Hershey Medical Center (Hershey, Pa.) on dry ice. Samples were stored at < or =-70 degrees C at both laboratories prior to testing. Pools of negative (donor), low-HIV-1-RNA-positive, and high-HIV-1-RNA-positive plasma samples were also repeatedly tested at CPAL to determine both intra- and interrun variation. From 11 August 1999 until 14 September 2000, 448 patient specimens were analyzed in parallel at CPAL and Hershey. From 206 samples with results of > or =1,000 copies/ml at CPAL, 148 (72%) of the results varied by < or =0.20 log(10) when tested at Hershey and none varied by >0.50 log(10). However, of 242 specimens with results of <1,000 copies/ml at CPAL, 11 (5%) of the results varied by >0.50 log(10) when tested at Hershey. Of 38 aliquots of HIV-1 RNA pool negative samples included in 13 CPAL bDNA runs, 37 (97%) gave results of <50 copies/ml and 1 (3%) gave a result of 114 copies/ml. Low-positive HIV-1 RNA pool intrarun variation ranged from 0.06 to 0.26 log(10) while the maximum interrun variation was 0.52 log(10). High-positive HIV-1 RNA pool intrarun variation ranged from 0.04 to 0.32 log(10), while the maximum interrun variation was 0.55 log(10). In our patient population, a change in bDNA HIV-1 RNA results of < or =0.50 log(10) over time most likely represents normal laboratory test variation. However, a change of >0.50 log(10), especially if the results are >1,000 copies/ml, is likely to be significant.


Assuntos
Infecções por HIV/diagnóstico , HIV-1/genética , HIV-1/isolamento & purificação , RNA Viral/análise , Ensaio de Amplificação de Sinal de DNA Ramificado/normas , Infecções por HIV/virologia , Humanos , RNA Viral/genética , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...