Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Vasc Surg ; 61(6): 1501-9.e1, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26004327

RESUMO

OBJECTIVE: Patients with limb-threatening ischemia exhibit uneven patterns of perfusion in the foot, which makes it challenging to determine adequate topographic perfusion by angiography alone. This study assessed the feasibility of reporting dynamic relative oxygen indices and tissue oxygen concentration from multiple locations on the foot during endovascular therapy using a novel micro-oxygen sensor (MOXY; PROFUSA, Inc, South San Francisco, Calif) approach. METHODS: A prospective, 28-day, single-arm, observational study was performed in 10 patients who underwent endovascular therapy for limb-threatening ischemia. At least 24 hours before therapy, four microsensors were injected in each patient (one in the arm, three in the treated foot). The optical signal from the microsensors corresponded to tissue oxygen concentration. A custom detector on the surface of the skin was used to continuously and noninvasively measure the signals from the microsensors. The ability to locate and read the signal from each injected microsensor was characterized. Oxygen data from the microsensors were collected throughout the revascularization procedure. The timing of therapy deployment was recorded during the procedure to assess its relationship with the microsensor oxygen data. Oxygen data collection and clinical evaluation were performed immediately postoperatively as well as postoperatively on days 7, 14, 21, and 28. RESULTS: The study enrolled 10 patients (50% male) with ischemia (30% Rutherford class 4, 70% Rutherford class 5). Patients were a mean age of 70.7 years (range, 46-90 years), and all were Hispanic of varying origin. Microsensors were successfully read 206 of 212 times (97.2%) in all patients during the course of the study. Microsensors were compatible with intraoperative use in the interventional suite and postoperatively in an office setting. In nine of 10 revascularization procedures, at least one of the three MOXYs showed an immediate change in the dynamic relative oxygen index, correlating to deployed therapy. Moreover, there was a statistically significant increase in the concentration of oxygen in the foot in preoperative levels compared with postoperative levels. No adverse events occurred related to the microsensor materials. CONCLUSIONS: This MOXY approach appears to be safe when implanted in patients with limb-threatening ischemia undergoing endovascular recanalization and is effective in reporting local tissue oxygen concentrations over a course of 28 days. Further testing is needed to determine its potential effect on clinical decision making, both acutely on-table and chronically as a surveillance modality, which ultimately can lead to improved healing and limb salvage.


Assuntos
Procedimentos Endovasculares , Pé/irrigação sanguínea , Isquemia/terapia , Oximetria/instrumentação , Oxigênio/sangue , Transdutores , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Costa Rica , Procedimentos Endovasculares/efeitos adversos , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Isquemia/sangue , Isquemia/diagnóstico , Isquemia/fisiopatologia , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Miniaturização , Valor Preditivo dos Testes , Estudos Prospectivos , Fluxo Sanguíneo Regional , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Resultado do Tratamento
2.
IEEE Trans Biomed Eng ; 62(1): 99-109, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25069107

RESUMO

In this paper, we describe the design and performance of the first integrated-circuit microsensor developed for daily ingestion by patients. The ingestible sensor is a device that allows patients, families, and physicians to measure medication ingestion and adherence patterns in real time, relate pharmaceutical compliance to important physiologic metrics, and take appropriate action in response to a patient's adherence pattern and specific health metrics. The design and theory of operation of the device are presented, along with key in-vitro and in-vivo performance results. The chemical, toxicological, mechanical, and electrical safety tests performed to establish the device's safety profile are described in detail. Finally, aggregate results from multiple clinical trials involving 412 patients and 5656 days of system usage are presented to demonstrate the device's reliability and performance as part of an overall digital health feedback system.


Assuntos
Conteúdo Gastrointestinal/química , Adesão à Medicação , Monitorização Ambulatorial/instrumentação , Comprimidos com Revestimento Entérico/análise , Comprimidos com Revestimento Entérico/química , Tecnologia sem Fio/instrumentação , Administração Oral , Animais , Condutometria/instrumentação , Cães , Monitoramento de Medicamentos , Ingestão de Alimentos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Concentração de Íons de Hidrogênio , Preparações Farmacêuticas/administração & dosagem , Preparações Farmacêuticas/análise , Preparações Farmacêuticas/química , Transdutores
3.
PLoS One ; 8(1): e53373, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23308203

RESUMO

Poor adherence to tuberculosis (TB) treatment hinders the individual's recovery and threatens public health. Currently, directly observed therapy (DOT) is the standard of care; however, high sustaining costs limit its availability, creating a need for more practical adherence confirmation methods. Techniques such as video monitoring and devices to time-register the opening of pill bottles are unable to confirm actual medication ingestions. A novel approach developed by Proteus Digital Health, Inc. consists of an ingestible sensor and an on-body wearable sensor; together, they electronically confirm unique ingestions and record the date/time of the ingestion. A feasibility study using an early prototype was conducted in active TB patients to determine the system's accuracy and safety in confirming co-ingestion of TB medications with sensors. Thirty patients completed 10 DOT visits and 1,080 co-ingestion events; the system showed 95.0% (95% CI 93.5-96.2%) positive detection accuracy, defined as the number of detected sensors divided by the number of transmission capable sensors administered. The specificity was 99.7% [95% CI 99.2-99.9%] based on three false signals recorded by receivers. The system's identification accuracy, defined as the number of correctly identified ingestible sensors divided by the number of sensors detected, was 100%. Of 11 adverse events, four were deemed related or possibly related to the device; three mild skin rashes and one complaint of nausea. The system's positive detection accuracy was not affected by the subjects' Body Mass Index (p = 0.7309). Study results suggest the system is capable of correctly identifying ingestible sensors with high accuracy, poses a low risk to users, and may have high patient acceptance. The system has the potential to confirm medication specific treatment compliance on a dose-by-dose basis. When coupled with mobile technology, the system could allow wirelessly observed therapy (WOT) for monitoring TB treatment as a replacement for DOT.


Assuntos
Antituberculosos/uso terapêutico , Técnicas Biossensoriais/instrumentação , Terapia Diretamente Observada/métodos , Adesão à Medicação/estatística & dados numéricos , Tuberculose Pulmonar/tratamento farmacológico , Administração Oral , Adulto , Idoso , Antituberculosos/farmacologia , Técnicas Biossensoriais/métodos , Índice de Massa Corporal , Terapia Diretamente Observada/ética , Esquema de Medicação , Estudos de Viabilidade , Feminino , Humanos , Masculino , Adesão à Medicação/psicologia , Pessoa de Meia-Idade , Estudos Prospectivos , Saúde Pública/ética , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...