Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Arch Ital Urol Androl ; : 12306, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38722142

RESUMO

INTRODUCTION: Benign prostatic hyperplasia is a prevalent disease that could be responsible of severe intractable hematuria requiring invasive surgical management. CASE PRESENTATION: We report three high-risk cases presented with intractable hematuria of prostatic origin with high medical co-morbidities treated safely and effectively by prostatic artery embolization with favorable outcomes. CONCLUSIONS: In non-surgical, anticoagulated patients, prostatic artery embolization represents a safe and effective intervention for the treatment of intractable hematuria related to benign prostatic hyperplasia.

2.
Am J Surg ; 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38448320

RESUMO

BACKGROUND: Ensuring ergonomic posture and safety for surgeons is key to preventing work-related injuries and promoting sustained practice. We evaluated ergonomic aspects of Anatomic Endoscopic Enucleation of the Prostate (AEEP) and its relation to musculoskeletal injuries. METHOD: A two-month online survey involving 119 Endourological Society members provided an in-depth analysis of AEEP practices and their musculoskeletal impacts. RESULTS: The sample experienced general (65.5%), back (32.8%), neck (35.3%) and shoulder (37%) pain. Female AEEP surgeons reported greater back pain. Experience and age were inversely related to MSK injuries, and operative times over 2 â€‹h increased back pain. AEEP procedures predominantly involved sitting (86%) on backless stools (58%), with most surgeons wearing protective eyewear (75.6%) and using large resectoscopes (76.5%). Monitors were usually above eye-level (57%) and beyond 1 â€‹m (68.9%). CONCLUSION: Musculoskeletal complaints are prevalent among AEEP endourologists. More awareness and further studies on risk factors are necessary to limit work-related injuries in urology.

4.
Arch Ital Urol Androl ; 95(1): 11201, 2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36924367

RESUMO

INTRODUCTION: Penile compression using a tourniquet is common with several materials and designs that have been previously described. The objective of the tourniquet is to induce an artificial erection through corporal occlusion for intra-operative penile curvature assessment or to obtain a clear visible bloodless surgical field. OBJECTIVE: We sought to describe our novel step-by-step technique of applying penile tourniquet using silicone Penrose drain tube designed as a strap by creating a small hole on the side of the tube to obtain a loop at the base of the penis Conclusions: This novel technique is simple, effective and requires no additional materials nor special equipment, and facilitates the application and release of a tourniquet during penile surgery.


Assuntos
Ereção Peniana , Pênis , Masculino , Humanos , Pênis/cirurgia
5.
Arch Ital Urol Androl ; 95(1): 11150, 2023 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-36924371

RESUMO

INTRODUCTION: Siliconoma represents an inflammatory tissue response to extravasated silicone. Penile enhancing silicone injections have been described for over 50 years. Most of the publications report complications including negative effects on penile appearance and function which require corrective procedures. Penile circumferential skin and siliconoma excision with skin grafting has been described in multiple case reports and series as an effective and feasible option to remove the silicone and achieve good esthetic results. METHODS: We describe a simple and feasible single stage procedure removing the siliconoma with adjacent non-viable skin while preserving 50% of healthy penile skin and resurfacing the defect with a split-thickness skin graft to treat a long-term complication of penile silicone injection associated with recurrent infections and a chronic skin ulceration. CONCLUSION: Partial excision of the affected penile skin and sili-conoma with defect resurfacing with a split-thickness skin graft is a feasible with good functional and cosmetic outcomes.


Assuntos
Pênis , Transplante de Pele , Masculino , Humanos , Pênis/cirurgia , Silicones
6.
Arch Ital Urol Androl ; 95(1): 11072, 2023 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-36924376

RESUMO

PURPOSE: To address the pattern of urodynamic findings in diabetic patients with lower urinary tract symptoms (LUTS), comparing short-standing and long-standing type 2 diabetes mellitus (T2DM). METHODS: A prospective study was conducted on 50 patients presenting with LUTS and a concurrent diagnosis of T2DM, between February 2016 and May 2018. Patients were classified and evaluated according to the duration of diabetes into two groups: short-standing DM (< 15 years, n = 31), and long-standing DM (≥ 15 years, n = 19) groups. The impact of LUTS and quality of life were assessed in female patients using ICIQ-FLUTS and male patients using ICIQ-MLUTS. RESULTS: A total of 50 patients were included in the study. The mean duration of T2DM was 10 ± 0.7 years. The mean age was 56.3 ± 1.2 years, and the mean HbA1c was 7.5 ± 1.2%. Urodynamic evaluation detected significantly higher detrusor overactivity (DO) and increased bladder sensation with the short-standing DM group (35.5 vs. 15.8%, p = 0.01 and 32.3 vs. 5.3%, p = 0.01, respectively). Comparatively, weak, or absent detrusor contractility were more frequent in patients with long-standing DM (52% and 26% respectively p = 0.01). As expected, overflow incontinence and straining during voiding were significantly higher in the long-standing DM group (p = 0.04 and p = 0.03, respectively). Surprisingly, there was no significant correlation between patients presenting with urgency in their voiding diary (subjective) and urodynamic detection of DO (p = 0.07). CONCLUSIONS: There are different patterns in urodynamic characterizations of T2DM. Patients with short-standing DM present more commonly with storage symptoms and detrusor overactivity on urodynamics. Contrastingly, patients with long-standing DM present more frequently with voiding symptoms and detrusor underactivity on urodynamics. Thus, screening for an underactive bladder is advisable in patients with long-standing T2DM.


Assuntos
Diabetes Mellitus Tipo 2 , Sintomas do Trato Urinário Inferior , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Diabetes Mellitus Tipo 2/complicações , Urodinâmica , Qualidade de Vida , Estudos Prospectivos , Sintomas do Trato Urinário Inferior/etiologia
7.
Can Urol Assoc J ; 17(4): 94-100, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36486176

RESUMO

INTRODUCTION: Competency by Design (CBD) is a form of competency-based medical education implemented in Canadian urology programs since 2018. Regular, multimethod assessments and formative feedback via Entrustable Professional Activities (EPAs) are the cornerstones of CBD. Personalized and regular feedback are the top perceived benefits of CBD by both residents and supervisors; however, evidence shows that in practice, constant feedback-seeking is burdensome, and increased quantity of feedback does not equal increased quality. The experience of CBD implementation has not yet been studied in surgical programs. Our aim was to examine how supervisors and residents have experienced the integration of formative assessment and feedback since the implementation of CBD in a surgical training program. METHODS: Using data from focus groups, a qualitative phenomenological analysis based on the experiences of the residents and supervisors in a urology residency program was performed. RESULTS: Residents and supervisors felt that CBD allowed for better tracking of resident performance and increased quantity of feedback; however, increased workload, delayed completion of EPA assessments, lack of direct observation in non-surgical activities, variable supervisor guidance, and lack of understanding of CBD were cited as barriers to providing proper feedback and formative assessment. CONCLUSIONS: The participants experienced a lukewarm transition in feedback and formative assessment practices with CBD. As with every process of change, these growing pains may eventually result in meaningful practice improvements and incorporation of a CBD culture into everyday learning activities.

8.
Arch Ital Urol Androl ; 94(4): 439-442, 2022 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-36576455

RESUMO

OBJECTIVE: To quantify the predictors for the ancillary treatments after extracorporeal shock wave lithotripsy (SWL) for renal and upper ureteral stones. MATERIALS AND METHODS: From January 2014 to January 2017, patients undergoing SWL using an electromagnetic lithotripter machine (Compact Delta; Dornier MedTech GmbH, Wessling, Germany) for renal and upper ureteral stones ≤ 20 mm were retrospectively reviewed. All patients underwent CT urography prior to SWL. The cohort was subdivided into three groups according to stone attenuation values in Hounsfield Units (HU). Group I; HU < 500 (n = 20), group II; HU 500-1000 (n = 51) and group III; HU ≥ 1000 (n = 180). The parameters included for multivariate analysis were stone size, location, multiplicity, stone attenuation value, number of shocks and stone clearance rate by 3 months. The ancillary treatments were ureteroscopy (URS), ureteral stenting and hospital readmission for pain or fever. RESULTS: A total of 251 patients were included in the study. The overall SWL success rate was 92.4%. Mean stone size was 10.9 ± 2.1, 11.6 ± 3 and 11.4 ± 3.6 mm and mean stone attenuation values were 364 ± 125, 811 ± 154 and 1285 ± 171 HU for groups I, II and III respectively. The stone clearance rates by 3 months were 96%, 92% and 88.4% for groups I, II and III respectively. On subgroup analysis, group III required ancillary treatments in 70% of patients whereas group I, II, did not require any ancillary treatments. On multivariate analysis, stone multiplicity, stone location (lower calyceal stones) and HU were independent significant predictors for the need for ancillary treatments after SWL (p values < 0.05). CONCLUSIONS: Patients with stone attenuation value (HU) > 1000, multiple stones and/or lower calyceal stones have higher risk to necessitate ancillary treatments after SWL. These patients would likely benefit from upfront endoscopic lithotripsy for treating symptomatic renal or upper ureteral stones.


Assuntos
Cálculos Renais , Litotripsia , Cálculos Ureterais , Humanos , Estudos Retrospectivos , Cálculos Ureterais/terapia , Cálculos Renais/diagnóstico por imagem , Cálculos Renais/terapia , Rim , Resultado do Tratamento
11.
J Urol ; 207(4): 866-875, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34854748

RESUMO

PURPOSE: The Optilume® drug-coated balloon (DCB) is a urethral dilation balloon with a paclitaxel coating that combines mechanical dilation for immediate symptomatic relief with local drug delivery to maintain urethral patency. The ROBUST III study is a randomized, single-blind trial evaluating the safety and efficacy of the Optilume DCB against endoscopic management of recurrent anterior urethral strictures. MATERIALS AND METHODS: Eligible patients were adult males with anterior strictures ≤12Fr in diameter and ≤3 cm in length, at least 2 prior endoscopic treatments, International Prostate Symptom Score ≥11 and maximum flow rate <15 ml per second. A total of 127 subjects were enrolled at 22 sites. The primary study end point was anatomical success (≥14Fr by cystoscopy or calibration) at 6 months. Key secondary end points included freedom from repeat treatment, International Prostatic Symptom Score and peak flow rate. The primary safety end point included freedom from serious device- or procedure-related complications. RESULTS: Baseline characteristics were similar between groups, with subjects having an average of 3.6 prior treatments and average length of 1.7 cm. Anatomical success for Optilume DCB was significantly higher than control at 6 months (75% vs 27%, p <0.001). Freedom from repeat intervention was significantly higher in the Optilume DCB arm. Immediate symptom and urinary flow rate improvement was significant in both groups, with the benefit being more durable in the Optilume DCB group. The most frequent adverse events included urinary tract infection, post-procedural hematuria and dysuria. CONCLUSIONS: The results of this randomized controlled trial support that Optilume is safe and superior to standard direct vision internal urethrotomy/dilation for the treatment of recurrent anterior urethral strictures <3 cm in length. The Optilume DCB may serve as an important alternative for men who have had an unsuccessful direct vision internal urethrotomy/dilation but want to avoid or delay urethroplasty.


Assuntos
Dilatação/métodos , Paclitaxel/administração & dosagem , Estreitamento Uretral/cirurgia , Adulto , Materiais Revestidos Biocompatíveis , Dilatação/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Método Simples-Cego , Resultado do Tratamento
12.
Can Urol Assoc J ; 16(12): 409-416, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36656697

RESUMO

INTRODUCTION: Anatomical endoscopic enucleation of the prostate (AEEP) is an effective treatment for benign prostatic hyperplasia (BPH); however, there is controversy regarding the difficulty of learning such a technique. Simulation-based training can mimic real-life surgeries and help surgeons develop skills they can transfer to the operating room, thereby improving patient safety. This study aimed to evaluate the validity of a novel organ phantom for use in AEEP simulation training. METHODS: Participants performed AEEP on organ phantom simulators during a Masterclass using one of three energy modalities: holmium:YAG laser, thulium fiber laser, or bipolar energy. The organ phantom is composed of hydrogels and uses 3D molds to recreate prostatic tissue. Participants completed a questionnaire assessing content validity, face validity, feasibility, and acceptability of using the prostate organ phantom. RESULTS: The novice group consisted of 13 urologists. The median number of AEEP previously performed was 0 (interquartile range [IQR] 0-2). Two experts in AEEP (surgeons having performed over 100 AEEP interventions) also participated. All participants agreed or strongly agreed that there is a role for simulators in AEEP training. Participants positively rated the overall operative experience (7.3/10). Morcellation (4.7/10) and hemostasis (3.1/10) were deemed the least realistic steps. All participants considered it feasible to incorporate this organ phantom into training programs and 92.9% agreed that it teaches skills transferrable to the operating room. CONCLUSIONS: This study has established content and face validity for AEEP with three different energy sources for an organ phantom. Participants considered its use both feasible and appropriate for AEEP training purposes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...