Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biosensors (Basel) ; 13(12)2023 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-38131756

RESUMO

Blood filtration using micro-fabricated devices is an interdisciplinary topic of research and innovation driven by clinical applications in cytapheresis, cardiovascular disease monitoring, or liquid biopsy. In this paper, we demonstrate that a micro-perforated membrane can be equipped with sensing microelectrodes for detecting, in situ and in real-time, the capture of cellular material during ex vivo filtration of whole blood under high flow rates. This work describes the fabrication process of the sift and detection microdevice. We demonstrate that reliable electrical signals can be measured in whole blood samples flowing inside a fluidic system at typical flow rates, as large as 11.5 mL/min, hence allowing for large-volume sample processing. The in situ monitoring of the electrical impedance of the microelectrodes is shown to characterize the accumulation of living circulating cells retained by the filtrating membrane, opening interesting applications for monitoring blood filtration processes.


Assuntos
Espectroscopia Dielétrica , Microeletrodos , Impedância Elétrica
2.
Sensors (Basel) ; 23(10)2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37430750

RESUMO

In this paper, a neural network approach is applied for solving an electromagnetic inverse problem involving solid dielectric materials subjected to shock impacts and interrogated by a millimeter-wave interferometer. Under mechanical impact, a shock wave is generated in the material and modifies the refractive index. It was recently demonstrated that the shock wavefront velocity and the particle velocity as well as the modified index in a shocked material can be remotely derived from measuring two characteristic Doppler frequencies in the waveform delivered by a millimeter-wave interferometer. We show here that a more accurate estimation of the shock wavefront and particle velocities can be obtained from training an appropriate convolutional neural network, especially in the important case of short-duration waveforms of few microseconds.

3.
Sensors (Basel) ; 22(24)2022 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-36559938

RESUMO

Blast waves generated by energetic materials involve very fast time variations in the pressure. One important issue for blast wave metrology is the accurate measurement (typical precision in the range of ±5% or better) of the static overpressure peak. For most near field configurations, this measurement requires ultra-fast sensors with response times lower than a few microseconds. In this paper, we design, model, fabricate and characterize a new ultra-fast sensor using piezo-resistive gauges at the center of a miniaturized and rectangular silicon membrane. When a pressure step of 10 bar is applied to the membrane, the signal delivered to the sensor output presents dampened oscillations, with a resonant frequency of 20.6 MHz and quality factor of 24,700 ns after the arrival of the shock wave. After removing undesirable drifts that appear after 700 ns, we may expect the sensor to have a response time (at ±5%) of 1.2 µs. Consequently, the proposed pressure sensor could be advantageously used for the accurate measurement of static overpressure peaks in blast wave experiments.

4.
Sensors (Basel) ; 22(10)2022 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-35632199

RESUMO

New broadband (>1 MHz) pressure sensors are regularly reported in the literature to measure the overpressure of blast waves. However, the frequency bandwidth needed to accurately measure such overpressure has not yet been clearly discussed. In this article, we present a methodology to determine the bandwidth required to estimate the overpressure magnitude at the front of a blast wave, in order to obtain a desired estimation accuracy. The bandwidth is derived here by using Kingery and Bulmash data.


Assuntos
Explosões , Leucócitos , Pressão
5.
Sensors (Basel) ; 21(23)2021 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-34884145

RESUMO

The automated quantification of the behaviour of freely moving animals is increasingly needed in applied ethology. State-of-the-art approaches often require tags to identify animals, high computational power for data collection and processing, and are sensitive to environmental conditions, which limits their large-scale utilization, for instance in genetic selection programs of animal breeding. Here we introduce a new automated tracking system based on millimetre-wave radars for real time robust and high precision monitoring of untagged animals. In contrast to conventional video tracking systems, radar tracking requires low processing power, is independent on light variations and has more accurate estimations of animal positions due to a lower misdetection rate. To validate our approach, we monitored the movements of 58 sheep in a standard indoor behavioural test used for assessing social motivation. We derived new estimators from the radar data that can be used to improve the behavioural phenotyping of the sheep. We then showed how radars can be used for movement tracking at larger spatial scales, in the field, by adjusting operating frequency and radiated electromagnetic power. Millimetre-wave radars thus hold considerable promises precision farming through high-throughput recording of the behaviour of untagged animals in different types of environments.


Assuntos
Movimento , Radar , Agricultura , Animais , Coleta de Dados , Monitorização Fisiológica , Ovinos
6.
Sensors (Basel) ; 21(17)2021 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-34502802

RESUMO

This paper reports the design, fabrication and measured performance of a passive microelectromechanical transducer for the wireless monitoring of high irradiation doses in nuclear environments. The sensing device is composed of a polymer material (high-density polyethylene) sealed inside a cavity. Subjected to ionizing radiation, this material releases various gases, which increases the pressure inside the cavity and deflects a dielectric membrane. From the measurement of the deflection, the variation of the applied pressure can be estimated, and, in turn, the dose may be determined. The microelectromechanical structure can also be used to study and validate the radiolysis properties of the polymer through its gas emission yield factor. Measurement of the dielectric membrane deflection is performed here to validate on the one hand the required airtightness of the cavity exposed to doses about 4 MGy and on the other hand, the functionality of the fabricated dosimeter for doses up to 80 kGy. The selection of appropriate materials for the microelectromechanical device is discussed, and the outgassing properties of the selected high-density polyethylene are analysed. Moreover, the technological fabrication process of the transducer is detailed.


Assuntos
Dosímetros de Radiação , Transdutores , Monitorização Fisiológica , Polímeros
7.
Sensors (Basel) ; 19(15)2019 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-31362437

RESUMO

This paper addresses the implementation of autonomous radiofrequency identification sensor nodes based on wireless power transfer. For size reduction, a switching method is proposed in order to use the same frequency band for both supplying power to the nodes and wirelessly transmitting the nodes' data. A rectenna harvests the electromagnetic energy delivered by the dedicated radiofrequency source for charging a few-mF supercapacitor. For supercapacitors of 7 mF, it is shown that the proposed autonomous sensor nodes were able to wirelessly communicate with the reader at 868 MHz for 10 min without interruption for a tag-to-reader separation distance of 1 meter. This result was obtained from effective radiated powers of 2 W during the supercapacitor charging and of 100 mW during the wireless data communication.

8.
Sensors (Basel) ; 19(6)2019 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-30871142

RESUMO

This paper reports the indoor wireless measurement of pressure from zero-power (or passive) microwave (24 GHz) sensors. The sensors are packaged and allow the remote measurement of overpressure up to 2.1 bars. Their design, fabrication process and packaging are detailed. From the measurement of sensor scattering parameters, the outstanding sensitivity of 995 MHz/bar between 0.8 and 2.1 bars was achieved with the full-scale measurement range of 1.33 GHz. Moreover, the 3D radar imagery technique was applied for the remote interrogation of these sensors in electromagnetic reverberant environments. The full-scale dynamic range of 4.9 dB and the sensitivity of 4.9 dB/bar between 0.7 and 1.7 bars were achieved with radar detection in a highly reflective environment. These measurement results demonstrate for the first time the ability of the radar imagery technique to interrogate fully passive pressure sensors in electromagnetic reverberant environments.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...