Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anesth Analg ; 94(6): 1474-8, table of contents, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12032010

RESUMO

UNLABELLED: In this prospective study, we evaluated the bispectral index (BIS) and postoperative recall during the intraoperative wake-up examination in 34 children and adolescents undergoing scoliosis surgery. Each anesthesiologist was blinded to BIS values throughout surgery and the wake-up test. The BIS, mean arterial blood pressure, and heart rate were compared at: before starting the wake-up test, patient movement to command, and after the patient was reanesthetized. The anesthetic technique for Group 1 was small-dose isoflurane, nitrous oxide, fentanyl, and midazolam and for Group 2 was nitrous oxide, fentanyl, and midazolam. Controlled hypotension was used for all cases. At patient movement to command, the patients were told a specific color to remember (teal) and on the second postoperative day were interviewed for explicit recall of the color and other intraoperative events. A total of 37 wake-up tests were performed in 34 patients. There was a significant increase in both groups of BIS (P < 0.001), mean arterial blood pressure (P < 0.001), and heart rate (P < 0.01) at the time of purposeful patient movement followed by a significant decline in BIS after reintroduction of anesthesia (P < 0.01). No patient recalled intraoperative pain, one patient recalled the wake-up test but not the color, and five patients recalled the specified color. We conclude that BIS may be a useful clinical monitor for predicting patient movement to command during the intraoperative wake-up test, particularly when controlled hypotension is used and hemodynamic responses to emergence of anesthesia are blunted. IMPLICATIONS: The relationship between bispectral index (BIS) and purposeful intraoperative patient movement is consistent with previous BIS utility studies. We conclude that BIS may be a useful clinical monitor for predicting patient movement to command during the intraoperative wake-up test, particularly when controlled hypotension is used and hemodynamic responses to emergence of anesthesia are blunted.


Assuntos
Anestesia , Eletroencefalografia/efeitos dos fármacos , Rememoração Mental , Monitorização Intraoperatória/métodos , Procedimentos Ortopédicos , Escoliose/cirurgia , Adolescente , Pressão Sanguínea/fisiologia , Criança , Feminino , Moduladores GABAérgicos/farmacologia , Frequência Cardíaca/fisiologia , Humanos , Masculino , Midazolam/farmacologia , Período Pós-Operatório , Estudos Prospectivos , Ressuscitação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...