Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Orthop Traumatol Surg Res ; 105(1): 1-3, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30584003
2.
J Arthroplasty ; 31(6): 1256-1260, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26718778

RESUMO

BACKGROUND: Total hip arthroplasty (THA) for intracapsular neck of femur (NOF) fracture remains debatable as it is associated with higher rates of dislocation, notably in the older part of the population. We hypothesized this risk could be limited using dual-mobility cups (DMCs). METHODS: Eighty-two patients (83 hips) aged older than 75 years underwent DMC-THA using a posterolateral approach for an intracapsular NOF fracture. RESULTS: Clinical data were collected in 45 patients at a mean of 23.8 ± 9.4 months (12.1-42 months). The mortality rates were 19% (16 patients) and 36.5% (30 patients) at 1 year postoperatively and at the last follow-up, respectively. Postoperatively, there were 2 dislocations of the large articulation (4.4%) and one intraprosthetic dislocation (2.2%), all related to technical errors. Functional results were rated at least good in 71% cases, whereas the Parker and Devane scores were stable, indicating optimal restoration of autonomy and physical activity. CONCLUSION: Although technically demanding, DMC-THA may prevent dislocation in intracapsular NOF fracture in elderly patients, while consistently limiting the risk of loss of independence.


Assuntos
Artroplastia de Quadril/métodos , Fraturas do Colo Femoral/cirurgia , Fêmur/cirurgia , Luxação do Quadril/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Prótese de Quadril , Humanos , Luxações Articulares/cirurgia , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Falha de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
3.
Acta Orthop ; 85(1): 91-6, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24286563

RESUMO

BACKGROUND AND PURPOSE: It is difficult to evaluate glenoid component periprosthetic radiolucencies in total shoulder arthroplasties (TSAs) using plain radiographs. This study was performed to evaluate whether computed tomography (CT) using a specific patient position in the CT scanner provides a better method for assessing radiolucencies in TSA. METHODS: Following TSA, 11 patients were CT scanned in a lateral decubitus position with maximum forward flexion, which aligns the glenoid orientation with the axis of the CT scanner. Follow-up CT scanning is part of our routine patient care. Glenoid component periprosthetic lucency was assessed according to the Molé score and it was compared to routine plain radiographs by 5 observers. RESULTS: The protocol almost completely eliminated metal artifacts in the CT images and allowed accurate assessment of periprosthetic lucency of the glenoid fixation. Positioning of the patient within the CT scanner as described was possible for all 11 patients. A radiolucent line was identified in 54 of the 55 observed CT scans and osteolysis was identified in 25 observations. The average radiolucent line Molé score was 3.4 (SD 2.7) points with plain radiographs and 9.5 (SD 0.8) points with CT scans (p = 0.001). The mean intra-observer variance was lower in the CT scan group than in the plain radiograph group (p = 0.001). INTERPRETATION: The CT scan protocol we used is of clinical value in routine assessment of glenoid periprosthetic lucency after TSA. The technique improves the ability to detect and monitor radiolucent lines and, therefore, possibly implant loosening also.


Assuntos
Artroplastia de Substituição/efeitos adversos , Prótese Articular , Falha de Prótese , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Idoso , Idoso de 80 Anos ou mais , Artefatos , Protocolos Clínicos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/cirurgia , Osteólise/etiologia , Posicionamento do Paciente/métodos , Articulação do Ombro/fisiopatologia , Tomografia Computadorizada por Raios X/métodos
4.
PLoS One ; 8(10): e75791, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24116075

RESUMO

BACKGROUND: The success of Total Shoulder Arthroplasty (TSA) is believed to depend on the restoration of the natural anatomy of the joint and a key development has been the introduction of modular humeral components to more accurately restore the patient's anatomy. However, there are no peer-reviewed studies that have reported the degree of glenoid component mal-position achieved in clinical practice and the clinical outcome of such mal-position. The main purpose of this study was to assess the accuracy of glenoid implant positioning during TSA and to relate it to the radiological (occurrence of radiolucent lines and osteolysis on CT) and clinical outcomes. METHODS: 68 TSAs were assessed with a mean follow-up of 38+/-27 months. The clinical evaluation consisted of measuring the mobility as well as of the Constant Score. The radiological evaluation was performed on CT-scans in which metal artefacts had been eliminated. From the CT-scans radiolucent lines and osteolysis were assessed. The positions of the glenoid and humeral components were also measured from the CT scans. RESULTS: Four position glenoid component parameters were calculated The posterior version (6°±12°; mean ± SD), the superior tilt (12°±17°), the rotation of the implant relative to the scapular plane (3°±14°) and the off-set distance of the centre of the glenoid implant from the scapular plane (6±4 mm). An inferiorly inclined implant was found to be associated with higher levels of radiolucent lines while retroversion and non-neutral rotation were associated with a reduced range of motion. CONCLUSION: this study demonstrates that glenoid implants of anatomic TSA are poorly positioned and that this malposition has a direct effect on the clinical and radiological outcome. Thus, further developments in glenoid implantation techniques are required to enable the surgeon to achieve a desired implant position and outcome.


Assuntos
Artroplastia de Substituição , Osteoartrite/cirurgia , Escápula/cirurgia , Articulação do Ombro/cirurgia , Ombro/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Osteoartrite/diagnóstico por imagem , Radiografia , Amplitude de Movimento Articular , Estudos Retrospectivos , Escápula/diagnóstico por imagem , Ombro/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem , Resultado do Tratamento
5.
Acta Orthop ; 83(5): 529-35, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23083436

RESUMO

BACKGROUND AND PURPOSE: Alignment of the glenoid component with the scapula during total shoulder arthroplasty (TSA) is challenging due to glenoid erosion and lack of both bone stock and guiding landmarks. We determined the extent to which the implant position is governed by the preoperative erosion of the glenoid. Also, we investigated whether excessive erosion of the glenoid is associated with perforation of the glenoid vault. METHODS: We used preoperative and postoperative CT scans of 29 TSAs to assess version, inclination, rotation, and offset of the glenoid relative to the scapula plane. The position of the implant keel within the glenoid vault was classified into three types: centrally positioned, component touching vault cortex, and perforation of the cortex. RESULTS: Preoperative glenoid erosion was statistically significantly linked to the postoperative placement of the implant regarding all position parameters. Retroversion of the eroded glenoid was on average 10° (SD10) and retroversion of the implant after surgery was 7° (SD11). The implant keel was centered within the vault in 7 of 29 patients and the glenoid vault was perforated in 5 patients. Anterior cortex perforation was most frequent and was associated with severe preoperative posterior erosion, causing implant retroversion. INTERPRETATION: The position of the glenoid component reflected the preoperative erosion and "correction" was not a characteristic of the reconstructive surgery. Severe erosion appears to be linked to vault perforation. If malalignment and perforation are associated with loosening, our results suggest reorientation of the implant relative to the eroded surface.


Assuntos
Artrite/cirurgia , Artroplastia de Substituição , Escápula/diagnóstico por imagem , Articulação do Ombro/cirurgia , Idoso , Artrite/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Articulação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X
6.
Clin Orthop Relat Res ; 470(10): 2776-84, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22733186

RESUMO

BACKGROUND: Repair of cuff tears involving rotator interval reportedly improves function. However, it is unclear whether successful repair prevents shoulder degenerative changes. QUESTIONS/PURPOSES: Therefore, we (1) documented the minimal 4-year function of patients who underwent open surgical repair for rotator interval tears; (2) evaluated repaired tendon healing with postoperative MRI; and (3) sought to determine the influence of tendon healing on muscular and glenohumeral joint changes. METHODS: We retrospectively analyzed 22 patients (23 shoulders) treated by open transosseous reinsertion of supraspinatus and subscapularis tendons. The mean age of the patients was 53 years (range, 37-64 years). The tear was traumatic in four cases. Repair healing and muscular changes were assessed using MRI. The minimum followup was 46 months (mean, 75 months; range, 46-103 months). RESULTS: We observed an improvement in the absolute Constant-Murley score from 63 points preoperatively to 76 points postoperatively. With the last followup MRI, the supraspinatus tendon repair had failed in two of the 23 shoulders, whereas the subscapularis tendon repair had healed in all cases. Once healing of the repaired tendon occurred, supraspinatus muscle atrophy never worsened. However, on MRI fatty infiltration of the rotator cuff muscles increased despite successful tendon repair. Glenohumeral arthritis remained stable. Postoperative abduction and internal rotation strengths were better when the standardized supraspinatus muscle area was greater than 0.5 at the final evaluation. CONCLUSION: Durable functional improvement and limited degenerative articular and muscular changes can be expected in most patients 4 to 10 years after open repair of anterosuperior cuff tears provided that healing of the cuff is obtained. LEVEL OF EVIDENCE: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.


Assuntos
Atrofia Muscular/prevenção & controle , Complicações Pós-Operatórias/prevenção & controle , Lesões do Manguito Rotador , Manguito Rotador/cirurgia , Tecido Adiposo/patologia , Adulto , Humanos , Pessoa de Meia-Idade , Atrofia Muscular/patologia , Procedimentos Ortopédicos/métodos , Complicações Pós-Operatórias/patologia , Estudos Retrospectivos , Manguito Rotador/patologia
8.
Acta Orthop ; 81(5): 563-9, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20860445

RESUMO

BACKGROUND: Current techniques for measuring in vivo polyethylene wear suffer from a range of problems, resulting in an unacceptable lack of repeatability and/or insufficient accuracy when they are used to measure the low wear rates associated with new, highly crosslinked polyethylene. We describe an improved CT method for measurement of 3D femoral head penetration in PE acetabular cups that has sufficient accuracy and repeatability to allow assessment of the wear potential of modern implants. METHOD: The accuracy and repeatability of the CT-scan method was determined by blindly repeating measurements on a precisely calibrated 28-mm prosthetic head and by comparing them with direct metrological measurements on 10 acetabular specimens with in vitro wear from machining, and on 8 explanted acetabular specimens with in vivo wear. RESULTS: The intra- and interobserver errors in femoral head diameter were 0.036 mm (SD 0.044) and 0.050 mm (SD 0.022), respectively. CT estimated femoral head penetration in both all-poly and metal-backed acetabular components with accuracy ranging from 0.009 to 0.245 mm (mean 0.080; SD 0.067). INTERPRETATION: We found that the CT method is rapid, is accurate, and has repeatability and ease of availability. Using a slice thickness of 0.0625 mm, this method can detect wear­and also the threshold for the wear rate that causes osteolysis­much earlier than previous methods.


Assuntos
Artroplastia de Quadril/efeitos adversos , Análise de Falha de Equipamento/métodos , Cabeça do Fêmur/diagnóstico por imagem , Falha de Prótese , Tomografia Computadorizada por Raios X/métodos , Acetábulo/diagnóstico por imagem , Prótese de Quadril/efeitos adversos , Humanos , Imageamento Tridimensional , Variações Dependentes do Observador , Osteólise/diagnóstico por imagem , Polietileno , Desenho de Prótese , Reprodutibilidade dos Testes
9.
Med Oncol ; 27(2): 446-8, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19444655

RESUMO

Sunitinib is a recently approved tyrosine-kinase inhibitor that targets the vascular endothelial growth factor receptors (VEGFR). We report two cases of patients with metastatic renal cell cancer who developed olecranon bursitis while receiving sunitinib. In both cases other causes of bursitis were excluded and the symptoms resolved after treatment with sunitinib was discontinued. Recurrence of symptoms during subsequent treatment cycles was also observed. This adverse event has not been previously reported for sunitinib and we believe it is directly attributable to the drug. This is an unexpected adverse event, given the mechanism of action of the drug. The pathophysiology of this event remains unexplained, although we describe some hypotheses.


Assuntos
Bursite/induzido quimicamente , Bursite/diagnóstico , Carcinoma de Células Renais/tratamento farmacológico , Indóis/efeitos adversos , Neoplasias Renais/tratamento farmacológico , Olécrano/patologia , Pirróis/efeitos adversos , Idoso , Carcinoma de Células Renais/patologia , Humanos , Indóis/uso terapêutico , Neoplasias Renais/patologia , Masculino , Pessoa de Meia-Idade , Pirróis/uso terapêutico , Sunitinibe , Resultado do Tratamento
10.
Clin Orthop Relat Res ; 467(10): 2613-22, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19499278

RESUMO

UNLABELLED: Open repair of full-thickness tears of the rotator cuff generally improves function, although anatomic failures are not uncommon. We asked whether the presence or absence of an anatomic repair influenced outcomes. We retrospectively analyzed 47 patients (49 shoulders) treated by open proximalized reinsertion of the supraspinatus tendon for chronic retracted detachment. The mean age of the patients at the time of surgery was 59 years. At a minimum 60-month followup (mean, 87 months; range, 60-133 months), we observed an improvement in the age- and gender-adjusted Constant-Murley score from 67% preoperatively to 95% postoperatively and in the pain score. With the last followup MRI, the supraspinatus tendon had reruptured in five patients (12%); the presence of a rerupture did not negatively influence the functional result. Once healing of the repaired tendons was achieved, supraspinatus muscle atrophy never worsened. However, on MRI, fatty infiltration of the supraspinatus, infraspinatus, and subscapularis muscles increased postoperatively despite tendon healing. Radiographic centering of the humeral head was preserved and glenohumeral arthritis remained stable. Functional results were better when the standardized supraspinatus muscle area was greater than 0.5 at the final evaluation. LEVEL OF EVIDENCE: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.


Assuntos
Imageamento por Ressonância Magnética , Procedimentos Ortopédicos , Reimplante , Manguito Rotador/cirurgia , Traumatismos dos Tendões/cirurgia , Atividades Cotidianas , Adulto , Idoso , Artrite/etiologia , Artrite/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Atrofia Muscular/etiologia , Atrofia Muscular/patologia , Medição da Dor , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Recidiva , Estudos Retrospectivos , Manguito Rotador/patologia , Manguito Rotador/fisiopatologia , Lesões do Manguito Rotador , Ruptura , Articulação do Ombro/patologia , Articulação do Ombro/fisiopatologia , Articulação do Ombro/cirurgia , Dor de Ombro/etiologia , Dor de Ombro/prevenção & controle , Traumatismos dos Tendões/complicações , Traumatismos dos Tendões/patologia , Traumatismos dos Tendões/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Cicatrização
11.
J Orthop Res ; 27(12): 1589-95, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19472376

RESUMO

Glenoid fixation failure has only been grossly characterized. This lack of information hinders attempts to improve fixation because of a lack of methodologies for detecting and monitoring fixation failure. Our goal was twofold: to collect detailed data of glenoid fixation fracture, and to investigate computed tomography (CT)-scanning as a tool for investigations of fixation failure. Six cadaver scapulas and six bone-substitute specimens were cyclically loaded and CT-scanned at clinical settings after 0, 1,000, 5,000, 10,000, 30,000, 50,000 and 70,000 load cycles. The fixation status was evaluated by inspection of the scans. After 70,000 cycles, the specimens were sectioned, and the fixation inspected by microscopy. The results of the microscopy analysis were compared to the CT-scan analysis. Fracture of the glenoid fixation initiated at the edge of the glenoid rim and propagated towards and around the keel of the implant. The entire process from initiation to complete fracture took place at the polyethylene implant-cement interface, while the cement, the adjacent bone, and the cement-bone interface remained intact. Thus, strengthening the polyethylene-cement interface should improve glenoid fixation. Microscopy results validated the CT methodology, suggesting that the CT technique is reliable.


Assuntos
Artroplastia de Substituição/efeitos adversos , Falha de Prótese , Luxação do Ombro/etiologia , Articulação do Ombro/cirurgia , Cadáver , Humanos , Técnicas In Vitro , Luxação do Ombro/diagnóstico por imagem , Luxação do Ombro/fisiopatologia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiopatologia , Estresse Mecânico , Tomografia Computadorizada por Raios X , Suporte de Carga
12.
Eur J Trauma Emerg Surg ; 34(6): 601-5, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26816287

RESUMO

Anterior shoulder dislocation is a very common trauma and the main complications are well documented. We report a case of aseptic osteonecrosis of the humeral head following an isolated episode of anterior glenohumeral dislocation without fracture that, to our knowledge, has never been reported in the literature.A 17-year-old male patient sustained an anterior glenohumeral dislocation following a sport accident. It was managed by reduction and immobilization. A radiologically identified aseptic osteonecrosis appeared 6 months later. The instability had been arthroscopically treated. At a follow-up of 4 years, the osteonecrosis has been stabilized leaving a mild arthrosis with stiffness, but without pain.

13.
Arch Orthop Trauma Surg ; 125(3): 201-3, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15723194

RESUMO

Published cases of non-traumatic avascular necrosis of the femoral head associated with pregnancy are rare. We report a case of a 41-year-old woman who suddenly complained of bilateral hip pain 3 weeks after delivery by Caesarean section. For a problem of sterility, she had been treated with human menopausal gonadotropin and human chorionic gonadotropin (hMG-hCG). Initial radiographs of both hip joints were considered regular. After 4 years' evolution, radiographs of the hip joint showed collapse of both femoral heads. Bilaterally, osteonecrosis of the femoral heads was confirmed by MRI. MRI revealed a band pattern of low signal intensity for both hips on T1- and T2-weighted images. She had no history of steroid therapy or alcohol abuse. Osteonecrosis was related to pretentaine. A bilateral total hip arthroplasty was performed. The literature about avascular necrosis of the femoral head associated with pregnancy in previous cases is reviewed.


Assuntos
Necrose da Cabeça do Fêmur/diagnóstico , Articulação do Quadril/fisiopatologia , Dor/fisiopatologia , Período Pós-Parto/fisiologia , Adulto , Artroplastia de Quadril , Gonadotropina Coriônica/uso terapêutico , Feminino , Necrose da Cabeça do Fêmur/cirurgia , Fármacos para a Fertilidade Feminina/uso terapêutico , Humanos , Infertilidade Feminina/tratamento farmacológico , Menotropinas/uso terapêutico , Gravidez
14.
Int Orthop ; 28(4): 226-30, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15168082

RESUMO

We retrospectively reviewed the charts of 29 patients younger than 65 years at surgery treated with deltoid flap reconstruction for massive postero-superior rotator cuff tears. All tears involved supraspinatus and infraspinatus tendons and were associated with tendon stump retraction to the glenoid rim, a preservable long biceps tendon, and an intact subscapularis tendon. Mean follow-up was 10.5 years. Patient satisfaction rate was 89%. Mean global Constant score improved from 43 to 71.5 points, mean pain score from 6.3 to 13.2, mean anterior flexion from 100 to 157 degrees, and force in elevation from 2.3 to 3 kg. Two thirds of patients had no humeral head migration. Of the 18 patients whose flap was examined by magnetic resonance imaging, 15 had no tear and 12 had a flap signal of muscle intensity; mean flap thickness was 5 mm. Pre-operative factors associated with poorer outcomes were upwards humeral head migration with a subacromial space smaller than 6 mm, presence of glenohumeral osteoarthritis, and supraspinatus amyotrophy greater than 40%. Deltoid flap reconstruction is a valid option in this patient population.


Assuntos
Músculo Esquelético/transplante , Lesões do Manguito Rotador , Manguito Rotador/cirurgia , Retalhos Cirúrgicos , Idoso , Distribuição de Qui-Quadrado , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
17.
Int Orthop ; 26(5): 306-9, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12378360

RESUMO

We conducted a prospective, randomised study on primary total knee replacements to evaluate the effects of tourniquet use on total calculated blood loss using Gross formula, post-operative measured blood loss, operating time, need for blood transfusion, post-operative pain, analgesia requirement and knee flexion. Forty patients were operated on with the use of an arterial tourniquet with pressure of 350 mmHg (group A), and 40 patients without the use of a tourniquet (group B). Total calculated blood loss was significantly increased ( P=0.0165) without the use of a tourniquet. There was no significant difference in measured blood loss or operating time. The median units of blood given were similar in both groups. In spite of autologous transfusions 14% of patients received additional homologous transfusions. At 6 h post-operatively pain was significantly less ( P=0.0458) in group B but was similar at 24 and 48 h. There was no significant difference in analgesia requirement. The mean change in total flexion in group B was significantly better ( P<0.001) at 5 days than in group A, but knee flexion was similar at 10 days and 3 months. Knee arthroplasty operations without the use of a tourniquet cause a greater blood loss but have only small benefits in the early post-operative period.


Assuntos
Artroplastia do Joelho , Perda Sanguínea Cirúrgica/prevenção & controle , Torniquetes , Adulto , Idoso , Idoso de 80 Anos ou mais , Transfusão de Sangue , Distribuição de Qui-Quadrado , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Prospectivos , Estatísticas não Paramétricas , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...