Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biorheology ; 37(4): 265-77, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11145073

RESUMO

Experiments were carried out in swine to test the hypothesis that changes in the fluid dynamic environment of the arterial wall, with time constants of several minutes to perhaps a few hours, prompt adaptive responses that transiently increase endothelial permeability. After parenteral Evans Blue Dye (EBD) administration, the hemodynamics of the external iliac arteries of the experimental animals were altered using a reversible arteriovenous femoral shunt. For 3 h, the shunt was opened and closed with a period (tau) between 1-180 min. Subsequently, the animal was euthanized and the iliac vessels were photographed en face to obtain the distribution of EBD-bound albumin uptake by the tissue during its exposure to the dye. Albumin uptake increases with tau in a fashion that can be explained by an a priori model of the adaptive permeability response, with a time constant of about an hour.


Assuntos
Adaptação Fisiológica , Arteriosclerose/etiologia , Endotélio Vascular/metabolismo , Periodicidade , Estresse Mecânico , Albuminas/metabolismo , Animais , Arteriosclerose/metabolismo , Permeabilidade Capilar , Densitometria , Azul Evans , Feminino , Substâncias Macromoleculares , Masculino , Modelos Animais , Transporte Proteico , Suínos
2.
Biorheology ; 36(3): 257-66, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10690272

RESUMO

In support of an in vivo investigation in swine of the influence of changes in fluid dynamic wall shear on arterial macromolecular permeability, a procedure has been developed to alter the flows in the porcine posterior arterial vasculature by opening and closing a reversible arteriovenous shunt placed on one of the femoral arteries. Laparoscopic techniques were used to place appropriately modified Transonic Systems ultrasonic flow probes on both external and circumflex iliac arteries, and on the terminal aorta. Flow measurements were made prior to shunt placement, and with the shunt open and closed, to measure the influence of altered external iliac artery flow on the distribution to the infrarenal abdominal vessels. Similar experiments were carried out to relate the flow rates in the external iliac arteries to those in the femoral arteries, which are more accessible. Based on the relationships among the measured flow rates, rules have been developed to estimate the major infrarenal flows in the pig, at baseline and with the shunt opened and closed, from only the flow rates measured at the two femoral arteries.


Assuntos
Artéria Femoral/fisiologia , Hemorreologia , Animais , Derivação Arteriovenosa Cirúrgica , Artéria Femoral/diagnóstico por imagem , Hemodinâmica , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/fisiologia , Fluxo Sanguíneo Regional , Estresse Mecânico , Suínos , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...