Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Invest Ophthalmol Vis Sci ; 65(6): 9, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38837167

RESUMO

Purpose: Optical coherence tomography (OCT) representations in clinical practice are static and do not allow for a dynamic visualization and quantification of blood flow. This study aims to present a method to analyze retinal blood flow dynamics using time-resolved structural OCT. Methods: We developed novel imaging protocols to acquire video-rate time-resolved OCT B-scans (1024 × 496 pixels, 10 degrees field of view) at four different sensor integration times (integration time of 44.8 µs at a nominal A-scan rate of 20 kHz, 22.4 µs at 40 kHz, 11.2 µs at 85 kHz, and 7.24 µs at 125 kHz). The vessel centers were manually annotated for each B-scan and surrounding subvolumes were extracted. We used a velocity model based on signal-to-noise ratio (SNR) drops due to fringe washout to calculate blood flow velocity profiles in vessels within five optic disc diameters of the optic disc rim. Results: Time-resolved dynamic structural OCT revealed pulsatile SNR changes in the analyzed vessels and allowed the calculation of potential blood flow velocities at all integration times. Fringe washout was stronger in acquisitions with longer integration times; however, the ratio of the average SNR to the peak SNR inside the vessel was similar across all integration times. Conclusions: We demonstrated the feasibility of estimating blood flow profiles based on fringe washout analysis, showing pulsatile dynamics in vessels close to the optic nerve head using structural OCT. Time-resolved dynamic OCT has the potential to uncover valuable blood flow information in clinical settings.


Assuntos
Fluxo Sanguíneo Regional , Vasos Retinianos , Tomografia de Coerência Óptica , Tomografia de Coerência Óptica/métodos , Humanos , Vasos Retinianos/fisiologia , Vasos Retinianos/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo/fisiologia , Fluxo Sanguíneo Regional/fisiologia , Disco Óptico/irrigação sanguínea , Disco Óptico/diagnóstico por imagem , Razão Sinal-Ruído , Masculino , Feminino , Adulto , Pessoa de Meia-Idade
2.
Transl Vis Sci Technol ; 11(1): 28, 2022 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-35044444

RESUMO

Purpose: The lateral resolution of an optical coherence tomography (OCT) instrument was considered to be equal to the illumination spot size on the retina. To evaluate the potential lateral resolution of the Spectralis OCT, an instrument calculated to have a 14 µm resolution. Methods: The lateral point spread function (PSF) was evaluated using diamond abrasive powder 0 to 1 µm in diameter in silicone elastomer and a validated target with 800 nm FeO particles in urethane. The amplitude transfer function was calculated from human OCT images. Finally, resolution was measured using the 1951 USAF target. Results: Measurement of the lateral PSF from 1215 diamond particle images yielded a full-width half maximum (FWHM) to be 5.11 µm and for 732 FeO particles, 4.9 µm. From the amplitude transfer function, the FWHM of the diffraction limited PSF was calculated to be 5.0 µm. The USAF target imaging showed a lateral resolution of 4.6 µm. Conclusions: Although a calculation of the spot size of the illumination beam was reported in the past as the lateral resolution of the OCT instrument, the actual lateral resolution is better by a factor of at least 2.5 times. The clinically used A-scan spacing was derived from the calculated, and not the true resolution, and results in under sampling. This set of findings likely apply to all commercial clinical instruments. Translational Relevance: The scan density parameters of past and present commercial OCT instruments were based on earlier translational concepts, which now appear to have been incorrect.


Assuntos
Retina , Tomografia de Coerência Óptica , Humanos
3.
Magn Reson Med ; 49(2): 276-87, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12541248

RESUMO

In this work absolute values of regional renal blood volume (rRBV) and flow (rRBF) are assessed by means of contrast-enhanced (CE) MRI using an intravascular superparamagnetic contrast agent. In an animal study, eight foxhounds underwent dynamic susceptibility-weighted MRI upon injection of contrast agent. Using principles of indicator dilution theory and deconvolution analysis, parametric images of rRBV, rRBF, and mean transit time (MTT) were computed. For comparison, whole-organ blood flow was determined invasively by means of an implanted flow probe, and the weight of the kidneys was evaluated postmortem. A mean rBV value of 28 ml/100 g was found in the renal cortex, with a corresponding mean rBF value of 524 ml/100 g/min and an average MTT of about 3.4 s. Although there was a systematic difference between the absolute blood flow values determined by MRI and the ultrasonic probe, a significant correlation (r(s) = 0.72, P < 0.05) was established. The influence of the arterial input function (AIF), T(1) relaxation effects, and repeated measurements on the precision of the perfusion quantitation is discussed.


Assuntos
Meios de Contraste/administração & dosagem , Ferro , Imageamento por Ressonância Magnética , Óxidos , Circulação Renal , Animais , Volume Sanguíneo , Dextranos , Cães , Óxido Ferroso-Férrico , Processamento de Imagem Assistida por Computador , Infusões Intravenosas , Ferro/administração & dosagem , Nanopartículas de Magnetita , Óxidos/administração & dosagem
4.
Magn Reson Med ; 49(2): 288-98, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12541249

RESUMO

The interrelation between the morphologic degree of renal artery stenosis and changes in parenchymal perfusion is assessed using an intravascular contrast agent. In seven adult foxhounds, different degrees of renal artery stenosis were created with an inflatable clamp implanted around the renal artery. Dynamic susceptibility-weighted gradient-echo imaging was used to measure signal-time curves in the renal artery and the renal parenchyma during administration of 1.5 mg/kg BW of an intravascular ultrasmall particle iron oxide (USPIO) contrast agent. From the dynamic series, regional renal blood volume (rRBV), regional renal blood flow (rRBF), and mean transit time (MTT) were calculated. The morphologic degree of stenosis was measured in the steady state using a high-resolution 3D contrast-enhanced (CE) MR angiography (MRA) sequence (voxel size = 0.7 x 0.7 x 1 mm(3)). Five patients with renoparenchymal damage due to long-standing renal artery stenosis were evaluated. In the animal stenosis model, cortical perfusion remained unchanged for degrees of renal artery stenosis up to 80%. With degrees of stenoses > 80%, cortical perfusion dropped to 151 +/- 54 ml/100 g of tissue per minute as compared to a baseline of 513 +/- 76 ml/100 g/min. In the patients, a substantial difference in the cortical perfusion of more than 200 +/- 40 ml/100 g/min between the normal and the ischemic kidneys was found. The results show that quantitative renal perfusion measurements in combination with 3D-CE-MRA allow the functional significance of a renal artery stenosis to be determined in a single MR exam. Differentiation between renovascular and renoparenchymal disease thus becomes feasible.


Assuntos
Meios de Contraste/administração & dosagem , Ferro , Imageamento por Ressonância Magnética , Óxidos , Obstrução da Artéria Renal/fisiopatologia , Circulação Renal , Angiografia Digital , Animais , Dextranos , Cães , Óxido Ferroso-Férrico , Humanos , Infusões Intravenosas , Ferro/administração & dosagem , Angiografia por Ressonância Magnética , Nanopartículas de Magnetita , Masculino , Pessoa de Meia-Idade , Óxidos/administração & dosagem , Obstrução da Artéria Renal/diagnóstico , Obstrução da Artéria Renal/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...