Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Mech Behav Biomed Mater ; 2(3): 237-42, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19627828

RESUMO

Biomedical devices and implants require precision joining for hermetic sealing which can be achieved with low power lasers. The effect of two different thin metal film coating methods was studied in transmission laser micro-joints of titanium-coated glass and polyimide. The coating methods were cathodic arc physical vapor deposition (CA-PVD) and electron beam evaporation (EB-PVD). Titanium-coated glass joined to polyimide film can have neural electrode application. The improvement of the joint quality will be essential for robust performance of the device. Low power fiber laser (wave length = 1100 nm) was used for transmission laser micro-joining of thin titanium (Ti) film (approximately 200 nm) coated Pyrex borosilicate 7740 glass wafer (0.5 mm thick) and polyimide (Imidex) film (0.2 mm thick). Ti film acts as the coupling agent in the joining process. The Ti film deposition rate in the CA-PVD was 5-10 A/s and in the EB-PVD 1.5 A/s. The laser joint strength was measured by a lap shear test, the Ti film surfaces were analyzed by atomic force microscopy (AFM) and the lap shear tested joints were analyzed by optical microscopy and scanning electron microscopy (SEM). The film properties and the failure modes of the joints were correlated to joint strength. The CA-PVD produced around 4 times stronger laser joints than EB-PVD. The adhesion of the Ti film on glass by CA-PVD is better than that of the EB-PVD method. This is likely to be due to a higher film deposition rate and consequently higher adhesion or sticking coefficient for the CA-PVD particles arriving on the substrate compared to that of the EB-PVD film. EB-PVD shows poor laser bonding properties due to the development of thermal hotspots which occurs from film decohesion.


Assuntos
Biotecnologia/métodos , Vidro , Lasers , Miniaturização/métodos , Resinas Sintéticas , Titânio , Biotecnologia/instrumentação , Análise de Falha de Equipamento , Microscopia Eletrônica de Varredura , Miniaturização/instrumentação , Resistência ao Cisalhamento
2.
Comput Methods Biomech Biomed Engin ; 12(1): 109-12, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18663613

RESUMO

The objective of this research is to design and optimise a mini/micro-channel based surface accumulator of Escherichia coli to be detected by acoustic wave biosensors. A computational research has been carried out using the state of the art software, CFD-ACE with water as bacteria bearing fluid. E. coli bacteria have been modelled as random discrete particles tracked by solving the Lagrangian equations. The design challenges are to achieve low shear force (pico-N), high concentration at accumulation and high enough Reynolds number to avoid bacteria swimming. A range of low Reynolds number (Re) from 28.2 to 58.3 has been considered along with the effects of particle-boundary interactions, gravity, Saffman lift and Magnus lift. About four orders of magnitude higher concentration at accumulation than the inlet concentration and lower shear force in the order of less than pico-N have been achieved in the optimised design with particles accumulating at a specific location under random particle-boundary interactions.


Assuntos
Técnicas Biossensoriais/instrumentação , Contagem de Colônia Microbiana/instrumentação , Escherichia coli/isolamento & purificação , Citometria de Fluxo/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Ultrafiltração/instrumentação , Microbiologia da Água , Acústica/instrumentação , Técnicas Biossensoriais/métodos , Contagem de Colônia Microbiana/métodos , Simulação por Computador , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Escherichia coli/fisiologia , Citometria de Fluxo/métodos , Técnicas Analíticas Microfluídicas/métodos , Modelos Biológicos , Ultrafiltração/métodos , Movimentos da Água
3.
Artigo em Inglês | MEDLINE | ID: mdl-18391246

RESUMO

A redesigned motion control system for the medical robot Aesop allows automating and programming its movements. An IR eye tracking system has been integrated with this control interface to implement an intelligent, autonomous eye gaze-based laparoscopic positioning system. A laparoscopic camera held by Aesop can be moved based on the data from the eye tracking interface to keep the user's gaze point region at the center of a video feedback monitor. This system setup provides autonomous camera control that works around the surgeon, providing an optimal robotic camera platform.


Assuntos
Computadores , Endoscópios , Movimentos Oculares , Software , Cirurgia Assistida por Computador/instrumentação , Humanos , Robótica/instrumentação , Estados Unidos , Interface Usuário-Computador
4.
Int J Med Robot ; 3(3): 217-23, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17823978

RESUMO

BACKGROUND: Many surgical robotic interfaces allow users to interact with robots over a wide potential range of motion, yet variation in operator performance across a range of motion remains unexamined. This research identifies and explores a new construct, the surgeon's 'comfortable working envelope' within the available range of motion, as a factor in surgical robotic interface design. METHODS: Task accuracy and completion time for a simple aimed movement task were analysed as a function of participant hand positions obtained via infrared motion tracking. RESULTS: Hand positions outside the 'comfortable working envelope' led to a 20% increase in error magnitude. With respect to the overall input device range of motion, there were large variations in performance, up to 31% difference in error magnitude and 11% difference in movement time. CONCLUSIONS: These results suggest that advanced surgical robots should have intelligent re-indexing strategies. Alternatively, the robot's control gain should adaptively change with respect to hand position to normalize a surgeon's performance throughout his/her working volume.


Assuntos
Mãos/fisiologia , Destreza Motora/fisiologia , Movimento/fisiologia , Postura/fisiologia , Robótica/métodos , Cirurgia Assistida por Computador/métodos , Análise e Desempenho de Tarefas , Interface Usuário-Computador , Adulto , Feminino , Humanos , Masculino
5.
Int J Med Robot ; 3: 82-8, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17441030

RESUMO

BACKGROUND: In this study we investigated the integration of a Raman spectroscopy-based biosensor with an image-guided surgery system. Such a system would provide a surgeon with both a diagnosis of the tissue being analysed (e.g. cancer) and localization information displayed within an imaging modality of choice. This type of mutual and registered information could lead to faster diagnoses and enable more accurate tissue resections. METHODS: A test bed consisting of a portable Raman probe attached to a passively articulated mechanical arm was used to scan and classify objects within a phantom skull. RESULTS: The prototype system was successfully able to track the Raman probe, classify objects within the phantom skull, and display the classifications on medical imaging data within a virtual reality environment. CONCLUSION: We discuss the implementation of the integrated system, its accuracy and improvements to the system that will enhance its usefulness and further the field of sensor-based computer-assisted surgery.


Assuntos
Técnicas Biossensoriais/instrumentação , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/cirurgia , Procedimentos Neurocirúrgicos/instrumentação , Análise Espectral Raman/instrumentação , Cirurgia Assistida por Computador/instrumentação , Técnicas Biossensoriais/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Procedimentos Neurocirúrgicos/métodos , Imagens de Fantasmas , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Análise Espectral Raman/métodos , Cirurgia Assistida por Computador/métodos , Transdutores
6.
J Mater Sci Mater Med ; 18(3): 417-27, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17334691

RESUMO

In this paper, laser bonded microjoints between glass and polyimide is considered to examine their potential applicability in encapsulating neural implants. To facilitate bonding between polyimide and glass, a thin titanium film with a thickness of 2 microm was deposited on borosilicate glass plates by a physical vapor deposition (PVD) process. Titanium coated glass was then joined with polyimide by using a cw fiber laser emitting at a wavelength of 1.1 microm (1.0 W) to prepare several tensile samples. Some of the samples were exposed to artificial cerebrospinal fluid (aCSF) at 37 degrees C for two weeks to assess long-term integrity of the joints. Both the as-received and aCSF soaked samples were subjected to uniaxial tensile loads for bond strengths measurements. The bond strengths for the as-received and aCSF soaked samples were measured to be 7.31 and 5.33 N/mm, respectively. Although the long-term exposure of the microjoints to aCSF has resulted in 26% reduction of bond strength, the samples still retain considerably high strength as compared with the titanium-polyimide samples. The failed glass/polyimide samples were also analyzed using optical microscopy, and failure mechanisms are discussed. In addition, a two dimensional finite element analysis (FEA) was conducted to understand the stress distribution within the substrate materials while the samples are in tension. The FEA results match reasonably well with the experimental load-displacement curves for as-received samples. Detailed discussion on various stress contours is presented in the paper, and the failure mechanisms observed from the experiment are shown in good agreement with the FEA predicted ones.


Assuntos
Materiais Biocompatíveis , Vidro , Polímeros , Engenharia Biomédica , Líquido Cefalorraquidiano , Análise de Elementos Finitos , Técnicas In Vitro , Lasers , Teste de Materiais , Procedimentos Neurocirúrgicos , Próteses e Implantes , Resistência à Tração , Titânio
7.
J Biomed Mater Res A ; 79(1): 159-65, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16779855

RESUMO

Assessment of neural biocompatibility requires that materials be tested with exposure in neural fluids. Laser bonded microjoint samples made from Ti coated glass substrate and polyimide film (GPI) and titanium foil and polyimide film (TIPI) were evaluated for mechanical performance before and after exposure in artificial cerebrospinal fluid (CSF) for two, four, and 12 weeks at 37 degrees C. These samples represent a critical feature, i.e., the microjoint-a major weakness in the bioencapsulation system. Both material systems showed initial degradation up to 4 weeks which then stabilized afterwards and retained similar strength until 12 weeks. The TIPI system appears to exhibit better overall performance with less degradation compared to its as-received strength. The CSF exposed TIPI samples predominantly failed at the interface, while GPI samples had mixed glass and polyimide substrate and interface failure. The amount of glass failure decreases and interface failure increases with increase in CSF exposure time. The failure mechanism of the as-received (not exposed to CSF) GPI samples under tension was predominantly flexure type failure of the glass substrate.


Assuntos
Materiais Biocompatíveis , Materiais Biomiméticos , Líquido Cefalorraquidiano , Vidro , Resinas Sintéticas , Titânio
8.
J Biomech Eng ; 128(3): 458-61, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16706596

RESUMO

The objective of this research is to design and optimize a mini/micro-channel based surface-accumulator of E. coli bacteria to be detected by acoustic wave biosensors. A computational approach has been carried out using the state of the art software, CFD-ACE with water as bacteria bearing fluid. E. coli bacteria have been modeled as random discrete particles tracked by solving the Lagrangian equations. The design challenges are to achieve low shear force (pico-N), high concentration at accumulation, and high enough Reynolds number to avoid bacteria swimming. A range of low Reynolds number (Re) has been considered along with the effects of particle boundary interactions, gravity, Saffman lift, etc. More than two orders of magnitude higher concentration at the accumulation than the inlet concentration, and lower shear force of less than pico-N have been achieved in the optimized designs.


Assuntos
Técnicas de Cultura de Células/instrumentação , Separação Celular/instrumentação , Contagem de Colônia Microbiana/instrumentação , Desenho Assistido por Computador , Escherichia coli/isolamento & purificação , Citometria de Fluxo/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Agregação Celular/fisiologia , Técnicas de Cultura de Células/métodos , Separação Celular/métodos , Contagem de Colônia Microbiana/métodos , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Escherichia coli/fisiologia , Citometria de Fluxo/métodos , Análise de Injeção de Fluxo/instrumentação , Análise de Injeção de Fluxo/métodos , Modelos Biológicos
9.
J Mater Sci Mater Med ; 16(3): 229-37, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15744614

RESUMO

Bioencapsulation of medical implant devices, and neural implant devices in particular, requires development of reliable hermetic joints between packaging materials that are often dissimilar. Titanium-polyimide is one of the biocompatible material systems, which are of interest to our research groups at Wayne State University and Fraunhofer USA. We have found processing conditions for successful joining of titanium with polyimide using near-infrared diode lasers or fiber lasers along transmission bonding lines with widths ranging from 200 to 300 microm. Laser powers of 2.2 and 3.8 W were used to create these joints. Laser-joined samples were tested in a microtester under tensile loading to determine joint strengths. In addition, finite element analysis (FEA) was conducted to understand the stress distribution within the bond area under tensile loading. The FEA model provides a full-field stress distribution in and around the joint that cause eventual failure. Results from the investigation provide an initial approach to characterize laser-fabricated microjoints between dissimilar materials that can be potentially used in optimization of bio-encapsulation design.


Assuntos
Imidas/química , Lasers , Polímeros/química , Próteses e Implantes , Titânio/química , Análise de Falha de Equipamento , Análise de Elementos Finitos , Raios Infravermelhos , Prótese Articular , Teste de Materiais/métodos , Microscopia , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração , Raios X
10.
Appl Opt ; 33(10): 1828-31, 1994 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-20885514

RESUMO

Dielectric multilayer antireflection coatings using TiO(2), SiO(2), Si(3)N(4), and Al(2)O(3) produce optimal results for a dual-wavelength optical data storage system to reduce the power requirement and enhance the Kerr rotation at blue wavelengths.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...