Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
4.
J AOAC Int ; 96(5): 1068-72, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24282949

RESUMO

After an assessment of data generated from a single-laboratory validation study published in J. AOAC Int. 95, 1469-1478 (2012), a method for determining total myo-inositol in infant formula and adult/ pediatric nutritional formula by high-performance anion exchange chromatography with pulsed amperometric detection (HPAEC-PAD), including extraction by using microwave-assisted acid hydrolysis and enzymatic treatment was presented for consideration by AOAC during the AOAC Annual Meeting held in Las Vegas, NV, from September 30 to October 3, 2012. The Expert Review Panel on Infant Formula and Adult Nutritionals concluded that the method met the criteria set by the standard method performance requirements (SMPRs) for the determination of free myo-inositol and approved the method as AOAC Official First Action. The method also determines total myo-inositol, but includes bound sources that the SMPRs exclude. The method involves using HPAEC-PAD for free myo-inositol and a total myo-inositol determination by two different techniques. The first technique uses the conventional acid hydrolysis with 6 h incubation in an autoclave. The second uses a microwave-assisted acid hydrolysis with enzymatic treatment that decreases the extraction time.


Assuntos
Cromatografia por Troca Iônica/métodos , Alimentos Formulados/análise , Fórmulas Infantis/química , Inositol/análise , Técnicas Eletroquímicas , Hidrólise , Inositol/isolamento & purificação , Micro-Ondas
5.
J AOAC Int ; 95(5): 1469-78, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23175982

RESUMO

A method for the analysis of free and total myo-inositol in foods, feeds, and infant formulas has been developed and validated using high-performance anion exchange chromatography with pulsed amperometric detection. The option of a free myo-inositol determination or a complete total myo-inositol determination from main bound sources can be achieved. These sources include phytates, lower'phosphorylated forms, and phosphatidylinositol. This approach gives the option for subtraction of myo-inositol from nonbioavailable sources when it is quantified using other methods if a total bioavailable myo-inositol result is desired for nutritional labeling of a product. The free analysis was validated in a milk-based infant formula, giving RSD(R) of 2.29% and RSD, of 2.06%. A mean recovery of 97.9% was achieved from various spike levels of myo-inositol. Certified National Institute of Standards and Technology reference material verified the method's compatibility and specificity. Two different total analyses were validated in a soy-based infant formula and compared. One technique involved using a conventional acid hydrolysis with autoclave incubation for 6 h, while the other used a novel technique of microwave-assisted acid hydrolysis with enzymatic treatment that can minimize extraction to 1 day. The autoclave analysis had RSD(R) of 2.08% and RSDr of 1.55%, along with a mean spike recovery of 102.1% at various myo-inositol spike levels. The microwave/enzyme total analysis had RSD(R) of 4.34% and RSD, of 4.70%, along with a mean spike recovery of 104.2% at various spike levels of myo-inositol. Main sources of myo-inositol including phytic acid and phosphatidylinositol were tested with both total analyses. Mean recoveries of phytic acid and phosphatidylinositol through the autoclave total analysis were 90.4 and 98.3%, respectively. Mean spike recoveries for these same sources in soy- based infant formula through the microwave/enzyme total analysis were 97.2 and 96.3%, respectively. Comparison of soy-based infant formula and corn grain samples with high levels of these main sources showed in similar results, indicating both total analyses are acceptable for use. An additional glycerol kinase step was also developed to remove glycerol from the chromatographic elution window of myoinositol in samples with high levels of glycerol.


Assuntos
Ração Animal/análise , Fracionamento Químico/métodos , Cromatografia/métodos , Análise de Alimentos/métodos , Alimentos Infantis/análise , Inositol/química , Ativação Enzimática , Contaminação de Alimentos , Humanos , Hidrólise , Lactente , Micro-Ondas , Padrões de Referência
6.
J AOAC Int ; 93(2): 499-509, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20480896

RESUMO

A collaborative study was conducted to evaluate the interlaboratory performance of an LC method for lycopene in dietary supplements and the raw materials commonly used in their manufacture. Twelve laboratories from six countries agreed to participate in the study. Results from 10 laboratories were received and are reported. Five dietary supplements, including both tablets and a softgel capsule with a lycopene content ranging from 25 microg to 25 mg per unit, and three raw materials, including gelatin-based beadlets, vegetarian beadlets, and a suspension in oil ranging from 5 to 20% lycopene, were analyzed as blind duplicates. In addition to the commercial products, two positive controls and a negative control were included in the study. For the raw materials studied, the repeatability relative standard deviations (RSDr) ranged from 1.49 to 5.13% for total lycopene, and the reproducibility relative standard deviations (RSDR) ranged from 3.84 to 9.21% with HorRat values from 1.23 to 3.24. For finished products, the RSDr ranged from 1.31 to 4.62%, RSDR from 4.28 to 10.5%, and HorRat values from 0.79 to 2.07. Corresponding values for all-trans-lycopene were significantly higher. It is recommended that the method be considered for Official First Action for all-trans- and total lycopene in finished products and raw materials.


Assuntos
Carotenoides/química , Cromatografia Líquida de Alta Pressão/métodos , Suplementos Nutricionais/análise , Calibragem , Cápsulas/análise , Carotenoides/análise , Géis/química , Concentração de Íons de Hidrogênio , Cooperação Internacional , Licopeno , Padrões de Referência , Reprodutibilidade dos Testes , Espectrofotometria/métodos , Comprimidos/análise , Água/química
7.
J AOAC Int ; 89(4): 942-59, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16915829

RESUMO

The presence of aristolochic acid in some dietary supplements is a concern to regulators and consumers. A method has been developed, by initially using a reference method as a guide, during single laboratory validation (SLV) for the determination of aristolochic acid I, also known as aristolochic acid A, in botanical species and dietary supplements at concentrations of approximately 2 to 32 microg/g. Higher levels were determined by dilution to fit the standard curve. Through the SLV, the method was optimized for quantification by liquid chromatography with ultraviolet detection (LC-UV) and LC/mass spectrometry (MS) confirmation. The test samples were extracted with organic solvent and water, then injected on a reverse phase LC column. Quantification was achieved with linear regression using a laboratory automation system. The SLV study included systematically optimizing the LC-UV method with regard to test sample size, fine grinding of solids, and solvent extraction efficiency. These parameters were varied in increments (and in separate optimization studies), in order to ensure that each parameter was individually studied; the test results include corresponding tables of parameter variations. In addition, the chromatographic conditions were optimized with respect to injection volume and detection wavelength. Precision studies produced overall relative standard deviation values from 2.44 up to 8.26% for aristolochic acid I. Mean recoveries were between 100 and 103% at the 2 microg/g level, between 102 and 103% at the 10 microg/g level, and 104% at the 30 microg/g level.


Assuntos
Ácidos Aristolóquicos/análise , Cromatografia Líquida/métodos , Suplementos Nutricionais/análise , Espectrometria de Massas/métodos , Acetonitrilas/análise , Técnicas de Química Analítica/métodos , Cromatografia Líquida de Alta Pressão , Íons , Metanol/análise , Raízes de Plantas , Reprodutibilidade dos Testes , Fatores de Tempo , Raios Ultravioleta , Água/análise
SELEÇÃO DE REFERÊNCIAS