Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Endovasc Ther ; 19(6): 707-15, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23210865

RESUMO

PURPOSE: To investigate the feasibility and early results of endoanchoring (endostapling) using a new commercially available device as an adjunctive procedure during endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms (AAAs) with an unfavorable proximal neck. METHODS: Between June 2010 and May 2012, 13 consecutive patients (all men; median age 73 years, range 62-82) were prospectively enrolled in a 2-center registry to follow outcomes of adjunctive primary endoanchoring (Aptus HeliFX Aortic Securement System) of the proximal endograft to enhance proximal graft fixation and sealing during EVAR. Indications for proximal neck endoanchoring included at least one of the following: neck angulation 45° to 90°, length 8 to 15 mm, diameter 29 to 33 mm, conical neck configuration, or an irregularly shaped neck. The median AAA diameter was 56 mm (range 50-98). The Endurant stent-graft was implanted in 4 patients and the Zenith device in 9. RESULTS: A median of 4 endoanchors were implanted per patient (range 3-10) in adjunctive procedures that required a median 12 minutes (range 7-20). Intraoperatively, 2 proximal type I endoleaks were present following endoanchor implantation (85% primary technical success); a cuff was deployed in 1 case, which successfully sealed the endoleak (92% assisted primary technical success). The second proximal type I endoleak was minute and sealed spontaneously within 30 days. No further major device-related complications occurred intraoperatively. In the 30-day perioperative period, the only procedure-related complications were 2 type II endoleaks, which required no intervention. Over a median follow-up of 7 months (range 2-17), no further complications occurred apart from an asymptomatic internal iliac artery occlusion and a non-lethal myocardial infarction at 9 months. The type II endoleaks spontaneously sealed. No endograft migration was noticed nor loss of endoanchor integrity. No deaths occurred throughout follow-up. CONCLUSION: Primary endoanchoring using the HeliFX aortic securement system is feasible, and early results were promising in this series.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares , Grampeamento Cirúrgico , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Stents , Grampeamento Cirúrgico/efeitos adversos , Grampeamento Cirúrgico/instrumentação , Suturas , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...