Ann Hepatol ; 11(1): 77-84, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22166564

RESUMO

BACKGROUND: There is an ongoing clinical need for novel methods to measure hepatic iron content (HIC) noninvasively. Both magnetic resonance imaging (MRI) and superconducting quantum interference device (SQUID) methods have previously shown promise for estimation of HIC, but these methods can be expensive and are not widely available. Room-temperature susceptometry (RTS) represents an inexpensive alternative and was previously found to be strongly correlated with HIC estimated by SQUID measurements among patients with transfusional iron overload related to thalassemia. AIM: The goal of the current study was to examine the relationship between RTS and biochemical HIC measured in liver biopsy specimens in a more varied patient cohort. MATERIAL AND METHODS: Susceptometry was performed in a diverse group of patients with hyperferritinemia due to hereditary hemochromatosis (HHC) (n = 2), secondary iron overload (n = 3), nonalcoholic fatty liver disease (NAFLD) (n = 2), and chronic viral hepatitis (n = 3) within one month of liver biopsy in the absence of iron depletion therapy. RESULTS: The correlation coefficient between HIC estimated by susceptometry and by biochemical iron measurement in liver tissue was 0.71 (p = 0.022). Variance between liver iron measurement and susceptometry measurement was primarily related to reliance on the patient's body-mass index (BMI) to estimate the magnetic susceptibility of tissue overlying the liver. CONCLUSIONS: We believe RTS holds promise for noninvasive measurement of HIC. Improved measurement techniques, including more accurate overlayer correction, may further improve the accuracy of liver susceptometry in patients with liver disease.


Assuntos
Técnicas e Procedimentos Diagnósticos/instrumentação , Ferritinas/sangue , Ferro/metabolismo , Fígado/metabolismo , Fígado/patologia , Campos Magnéticos , Temperatura , Adulto , Idoso , Biópsia , Estudos de Coortes , Fígado Gorduroso/metabolismo , Fígado Gorduroso/patologia , Feminino , Hemocromatose/metabolismo , Hemocromatose/patologia , Hepatite Crônica/metabolismo , Hepatite Crônica/patologia , Humanos , Sobrecarga de Ferro/metabolismo , Sobrecarga de Ferro/patologia , Cirrose Hepática/metabolismo , Cirrose Hepática/patologia , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica , Valor Preditivo dos Testes
2.
Physiol Meas ; 28(4): 349-61, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17395991

RESUMO

Magnetic susceptibility measurements on the liver can quantify iron overload accurately and noninvasively. However, established susceptometer designs, using superconducting quantum interference devices (SQUIDs) that work in liquid helium, have been too expensive for widespread use. This paper presents a less expensive liver susceptometer that works at room temperature. This system uses oscillating magnetic fields, which are produced and detected by copper coils. The coil design cancels the signal from the applied field, eliminating noise from fluctuations of the source-coil current and sensor gain. The coil unit moves toward and away from the patient at 1 Hz, cancelling drifts due to thermal expansion of the coils. Measurements on a water phantom indicated instrumental errors less than 30 microg of iron per gram of wet liver tissue, which is small compared with other errors due to the response of the patient's body. Liver-iron measurements on eight thalassemia patients yielded a correlation coefficient r = 0.98 between the room-temperature susceptometer and an existing SQUID. These results indicate that the fundamental accuracy limits of the room-temperature susceptometer are similar to those of the SQUID.


Assuntos
Ferro/análise , Fígado/metabolismo , Magnetismo/instrumentação , Talassemia/diagnóstico , Talassemia/metabolismo , Adolescente , Adulto , Biomarcadores/análise , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Temperatura , Transdutores