Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Orbit ; 43(1): 16-21, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36789974

RESUMO

PURPOSE: To present a simplified technique in management of complete ptosis secondary to neurofibromatosis. METHODS: This prospective, non-comparative, clinical interventional study included 13 patients with complete ptosis secondary to histologically proved plexiform neurofibromas. It was conducted at the Orbital Unit of Assiut University Hospital, the referral center of Upper Egypt in the period between June 2013 and October 2021. In all cases, a simplified technique of 5 surgical steps was applied: (A) Division of the involved eyelid surgically into three parts by drawing 2 curvilinear lines, the superior line 11 mm below and parallel to the lower eyebrow hairline and the inferior one 10 mm above the lid margin, (B) Resection (full-thickness) of the large middle part which involves the main pathology and lies between the 2 lines, (C) Preservation of the upper part with identification, dissection and clamping of the levator muscle, (D) Refinement of the lower part by removal of any tissue between the skin and the debulked tarsus and (E) Re-suturing of the upper and lower parts in layers; conjunctiva to conjunctiva, levator to tarsus (after resection of a part that corrects the ptosis) and skin to skin. RESULTS: Ptosis was completely corrected in 8 cases (61.5%) and residual mild ptosis occurred in 5 patients (38.5%). No exposure keratopathy or tumor growth was reported during the follow-up period of minimum 1 year. CONCLUSIONS: This simplified technique could be considered as a surgical basis for correction of complete ptosis in neurofibromatosis.


Assuntos
Blefaroplastia , Blefaroptose , Neurofibromatoses , Humanos , Blefaroplastia/métodos , Estudos Prospectivos , Blefaroptose/etiologia , Blefaroptose/cirurgia , Pálpebras/cirurgia , Neurofibromatoses/complicações , Neurofibromatoses/cirurgia , Estudos Retrospectivos , Músculos Oculomotores/cirurgia
2.
Adv Mater ; 36(5): e2305002, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37990141

RESUMO

Nano-constriction based spin Hall nano-oscillators (SHNOs) are at the forefront of spintronics research for emerging technological applications, such as oscillator-based neuromorphic computing and Ising Machines. However, their miniaturization to the sub-50 nm width regime results in poor scaling of the threshold current. Here, it shows that current shunting through the Si substrate is the origin of this problem and studies how different seed layers can mitigate it. It finds that an ultra-thin Al2 O3 seed layer and SiN (200 nm) coated p-Si substrates provide the best improvement, enabling us to scale down the SHNO width to a truly nanoscopic dimension of 10 nm, operating at threshold currents below 30 µ $\umu$ A. In addition, the combination of electrical insulation and high thermal conductivity of the Al2 O3 seed will offer the best conditions for large SHNO arrays, avoiding any significant temperature gradients within the array. The state-of-the-art ultra-low operational current SHNOs hence pave an energy-efficient route to scale oscillator-based computing to large dynamical neural networks of linear chains or 2D arrays.

3.
Nano Lett ; 23(14): 6720-6726, 2023 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-37450893

RESUMO

Mutual synchronization of N serially connected spintronic nano-oscillators boosts their coherence by N and peak power by N2. Increasing the number of synchronized nano-oscillators in chains holds significance for improved signal quality and emerging applications such as oscillator based unconventional computing. We successfully fabricate spin Hall nano-oscillator chains with up to 50 serially connected nanoconstrictions using W/NiFe, W/CoFeB/MgO, and NiFe/Pt stacks. Our experiments demonstrate robust and complete mutual synchronization of 21 nanoconstrictions at an operating frequency of 10 GHz, achieving line widths <134 kHz and quality factors >79,000. As the number of mutually synchronized oscillators increases, we observe a quadratic increase in peak power, resulting in 400-fold higher peak power in long chains compared to individual nanoconstrictions. While chains longer than 21 nanoconstrictions also achieve complete mutual synchronization, it is less robust, and their signal quality does not improve significantly, as they tend to break into partially synchronized states.

4.
Microsyst Nanoeng ; 8: 65, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35721373

RESUMO

Magnetic force microscopy (MFM) is a powerful technique for studying magnetic microstructures and nanostructures that relies on force detection by a cantilever with a magnetic tip. The detected magnetic tip interactions are used to reconstruct the magnetic structure of the sample surface. Here, we demonstrate a new method using MFM for probing the spatial profile of an operational nanoscale spintronic device, the spin Hall nano-oscillator (SHNO), which generates high-intensity spin wave auto-oscillations enabling novel microwave applications in magnonics and neuromorphic computing. We developed an MFM system by adding a microwave probe station to allow electrical and microwave characterization up to 40 GHz during the MFM process. SHNOs-based on NiFe/Pt bilayers with a specific design compatible with the developed system-were fabricated and scanned using a Co magnetic force microscopy tip with 10 nm spatial MFM resolution, while a DC current sufficient to induce auto-oscillation flowed. Our results show that this developed method provides a promising path for the characterization and nanoscale magnetic field imaging of operational nano-oscillators.

5.
Nat Commun ; 13(1): 2462, 2022 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-35513369

RESUMO

Magnetic droplets are non-topological magnetodynamical solitons displaying a wide range of complex dynamic phenomena with potential for microwave signal generation. Bubbles, on the other hand, are internally static cylindrical magnetic domains, stabilized by external fields and magnetostatic interactions. In its original theory, the droplet was described as an imminently collapsing bubble stabilized by spin transfer torque and, in its zero-frequency limit, as equivalent to a bubble. Without nanoscale lateral confinement, pinning, or an external applied field, such a nanobubble is unstable, and should collapse. Here, we show that we can freeze dynamic droplets into static nanobubbles by decreasing the magnetic field. While the bubble has virtually the same resistance as the droplet, all signs of low-frequency microwave noise disappear. The transition is fully reversible and the bubble can be thawed back into a droplet if the magnetic field is increased under current. Whereas the droplet collapses without a sustaining current, the bubble is highly stable and remains intact for days without external drive. Electrical measurements are complemented by direct observation using scanning transmission x-ray microscopy, which corroborates the analysis and confirms that the bubble is stabilized by pinning.

6.
Opt Express ; 28(20): 29540-29552, 2020 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-33114852

RESUMO

Brillouin light scattering (BLS) microscopy is a well established and powerful technique to study acoustic and magnetic excitations in the frequency domain with sub-micron spatial resolution. Many other spectroscopic techniques have benefited from the introduction of femtosecond laser sources to optically pump and stimulate the sample under investigation. In BLS microscopy, the use of femtosecond lasers as the excitation source introduces several challenges, primarily since the measured frequency shift is small and the signal levels are weak due to the low duty cycle of typical femtosecond lasers. Here we present a method to evade these challenges. A strong enhancement of the weak scattering amplitude on selected modes is observed by pumping the sample with a high repetition rate frequency comb laser source. The laser beam can be focused to the diffraction limit, providing a micron pumping area. We can thus preserve the innate high frequency and spatial resolution of BLS microscopy. Furthermore, we are able to induce a point-like source of mode-selected elementary excitations which propagate away from the pumping spot. We conclude that we have demonstrated frequency comb pumped BLS microscopy as an attractive tool for studies of ultrafast induced laser dynamics directly in the frequency domain.

7.
Nat Nanotechnol ; 15(1): 47-52, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31873287

RESUMO

In spin Hall nano-oscillators (SHNOs), pure spin currents drive local regions of magnetic films and nanostructures into auto-oscillating precession. If such regions are placed in close proximity to each other they can interact and may mutually synchronize. Here, we demonstrate robust mutual synchronization of two-dimensional SHNO arrays ranging from 2 × 2 to 8 × 8 nano-constrictions, observed both electrically and using micro-Brillouin light scattering microscopy. On short time scales, where the auto-oscillation linewidth [Formula: see text] is governed by white noise, the signal quality factor, [Formula: see text], increases linearly with the number of mutually synchronized nano-constrictions (N), reaching 170,000 in the largest arrays. We also show that SHNO arrays exposed to two independently tuned microwave frequencies exhibit the same synchronization maps as can be used for neuromorphic vowel recognition. Our demonstrations may hence enable the use of SHNO arrays in two-dimensional oscillator networks for high-quality microwave signal generation and ultra-fast neuromorphic computing.

8.
Nat Commun ; 10(1): 2362, 2019 05 29.
Artigo em Inglês | MEDLINE | ID: mdl-31142758

RESUMO

Spin torque and spin Hall effect nano-oscillators generate high intensity spin wave auto-oscillations on the nanoscale enabling novel microwave applications in spintronics, magnonics, and neuromorphic computing. For their operation, these devices require externally generated spin currents either from an additional ferromagnetic layer or a material with a high spin Hall angle. Here we demonstrate highly coherent field and current tunable microwave signals from nano-constrictions in single 15-20 nm thick permalloy layers with oxide interfaces. Using a combination of spin torque ferromagnetic resonance measurements, scanning micro-Brillouin light scattering microscopy, and micromagnetic simulations, we identify the auto-oscillations as emanating from a localized edge mode of the nano-constriction driven by spin-orbit torques. Our results pave the way for greatly simplified designs of auto-oscillating nano-magnetic systems only requiring single ferromagnetic layers with oxide interfaces.

9.
Phys Rev Lett ; 120(21): 217204, 2018 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-29883139

RESUMO

Magnetic droplets are nontopological dynamical solitons that can be nucleated in nanocontact based spin torque nano-oscillators (STNOs) with perpendicular magnetic anisotropy free layers. While theory predicts that the droplet should be of the same size as the nanocontact, its inherent drift instability has thwarted attempts at observing it directly using microscopy techniques. Here, we demonstrate highly stable magnetic droplets in all-perpendicular STNOs and present the first detailed droplet images using scanning transmission X-ray microscopy. In contrast to theoretical predictions, we find that the droplet diameter is about twice as large as the nanocontact. By extending the original droplet theory to properly account for the lateral current spread underneath the nanocontact, we show that the large discrepancy primarily arises from current-in-plane Zhang-Li torque adding an outward pressure on the droplet perimeter. Electrical measurements on droplets nucleated using a reversed current in the antiparallel state corroborate this picture.

10.
Sci Rep ; 7(1): 13422, 2017 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-29044190

RESUMO

An important property of spin-torque nano-oscillators (STNOs) is their ability to produce a frequency modulated (FM) signal, which is very critical for communication applications. We here demonstrate a novel single sideband (SSB) modulation phenomenon using a magnetic tunnel junction (MTJ)-based STNO, which saves transmission bandwidth and in principle should minimize attenuation for wireless communication. Experimentally, lower single sidebands (LSSBs) have been successfully demonstrated over a wide range of modulation frequency, f m = 150 MHz-1 GHz. The observed LSSBs are determined by the intrinsic properties of the device, which can be modeled well by a nonlinear frequency and amplitude modulation formulation and reproduced in macrospin simulations. Moreover, our macrospin simulation results show that the range of modulation current and modulation frequency for generating SSBs can be controlled by the field-like torque and biasing conditions.

11.
Nanoscale ; 9(3): 1285-1291, 2017 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-28054694

RESUMO

Spin Hall nano-oscillators (SHNOs) are an emerging class of pure spin current driven microwave signal generators. Through the fabrication of 20 nm nano-constrictions in Pt/NiFe bilayers, we demonstrate that SHNOs can be scaled down to truly nanoscopic dimensions, with the added benefit of ultra-low operating currents and improved power conversion efficiency. The lateral confinement leads to a strong shape anisotropy field as well as an additional demagnetizing field whose reduction with increasing auto-oscillation amplitude can yield a positive current tunability contrary to the negative tunability commonly observed for localized excitations in extended magnetic layers. Micromagnetic simulations corroborate the experimental findings and suggest that the active magnetodynamic area resides up to 100 nm outside of the nano-constriction.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...