Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Comput Assist Radiol Surg ; 19(1): 119-127, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37418109

RESUMO

PURPOSE: Medical imaging can be used to estimate a patient's biological age, which may provide complementary information to clinicians compared to chronological age. In this study, we aimed to develop a method to estimate a patient's age based on their chest CT scan. Additionally, we investigated whether chest CT estimated age is a more accurate predictor of lung cancer risk compared to chronological age. METHODS: To develop our age prediction model, we utilized composite CT images and Inception-ResNet-v2. The model was trained, validated, and tested on 13,824 chest CT scans from the National Lung Screening Trial, with 91% for training, 5% for validation, and 4% for testing. Additionally, we independently tested the model on 1849 CT scans collected locally. To assess chest CT estimated age as a risk factor for lung cancer, we computed the relative lung cancer risk between two groups. Group 1 consisted of individuals assigned a CT age older than their chronological age, while Group 2 comprised those assigned a CT age younger than their chronological age. RESULTS: Our analysis revealed a mean absolute error of 1.84 years and a Pearson's correlation coefficient of 0.97 for our local data when comparing chronological age with the estimated CT age. The model showed the most activation in the area associated with the lungs during age estimation. The relative risk for lung cancer was 1.82 (95% confidence interval, 1.65-2.02) for individuals assigned a CT age older than their chronological age compared to those assigned a CT age younger than their chronological age. CONCLUSION: Findings suggest that chest CT age captures some aspects of biological aging and may be a more accurate predictor of lung cancer risk than chronological age. Future studies with larger and more diverse patients are required for the generalization of the interpretations.


Assuntos
Aprendizado Profundo , Neoplasias Pulmonares , Humanos , Tomografia Computadorizada por Raios X/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Radiografia , Pulmão/diagnóstico por imagem
2.
Int J Comput Assist Radiol Surg ; 18(10): 1903-1914, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36947337

RESUMO

PURPOSE: The usage of iodinated contrast media (ICM) can improve the sensitivity and specificity of computed tomography (CT) for many clinical indications. However, the adverse effects of ICM administration can include renal injury, life-threatening allergic-like reactions, and environmental contamination. Deep learning (DL) models can generate full-dose ICM CT images from non-contrast or low-dose ICM administration or generate non-contrast CT from full-dose ICM CT. Eliminating the need for both contrast-enhanced and non-enhanced imaging or reducing the amount of required contrast while maintaining diagnostic capability may reduce overall patient risk, improve efficiency and minimize costs. We reviewed the current capabilities of DL to reduce the need for contrast administration in CT. METHODS: We conducted a systematic review of articles utilizing DL to reduce the amount of ICM required in CT, searching MEDLINE, Embase, Compendex, Inspec, and Scopus to identify papers published from 2016 to 2022. We classified the articles based on the DL model and ICM reduction. RESULTS: Eighteen papers met the inclusion criteria for analysis. Of these, ten generated synthetic full-dose (100%) ICM from real non-contrast CT, while four augmented low-dose to full-dose ICM CT. Three used DL to create synthetic non-contrast CT from real 100% ICM CT, while one paper used DL to translate the 100% ICM to non-contrast CT and vice versa. DL models commonly used generative adversarial networks trained and tested by paired contrast-enhanced and non-contrast or low ICM CTs. Image quality metrics such as peak signal-to-noise ratio and structural similarity index were frequently used for comparing synthetic versus real CT image quality. CONCLUSION: DL-generated contrast-enhanced or non-contrast CT may assist in diagnosis and radiation therapy planning; however, further work to optimize protocols to reduce or eliminate ICM for specific pathology is still needed along with a dedicated assessment of the clinical utility of these synthetic images.


Assuntos
Meios de Contraste , Aprendizado Profundo , Humanos , Tomografia Computadorizada por Raios X/métodos
3.
Sci Rep ; 11(1): 13246, 2021 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-34168226

RESUMO

Algae are the main primary producers in aquatic environments and therefore of fundamental importance for the global ecosystem. Mid-infrared (IR) microspectroscopy is a non-invasive tool that allows in principle studying chemical composition on a single-cell level. For a long time, however, mid-infrared (IR) imaging of living algal cells in an aqueous environment has been a challenge due to the strong IR absorption of water. In this study, we employed multi-beam synchrotron radiation to measure time-resolved IR hyperspectral images of individual Thalassiosira weissflogii cells in water in the course of acclimation to an abrupt change of CO2 availability (from 390 to 5000 ppm and vice versa) over 75 min. We used a previously developed algorithm to correct sinusoidal interference fringes from IR hyperspectral imaging data. After preprocessing and fringe correction of the hyperspectral data, principal component analysis (PCA) was performed to assess the spatial distribution of organic pools within the algal cells. Through the analysis of 200,000 spectra, we were able to identify compositional modifications associated with CO2 treatment. PCA revealed changes in the carbohydrate pool (1200-950 cm[Formula: see text]), lipids (1740, 2852, 2922 cm[Formula: see text]), and nucleic acid (1160 and 1201 cm[Formula: see text]) as the major response of exposure to elevated CO2 concentrations. Our results show a local metabolism response to this external perturbation.


Assuntos
Dióxido de Carbono/farmacologia , Diatomáceas/efeitos dos fármacos , Análise de Célula Única/métodos , Aclimatação , Diatomáceas/metabolismo , Espectrofotometria Infravermelho , Síncrotrons , Imagem com Lapso de Tempo
4.
Analyst ; 143(19): 4674-4683, 2018 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-30176033

RESUMO

Short-term acclimation response of individual cells of Thalassiosira weissflogii was monitored by Synchrotron FTIR imaging over the span of 75 minutes. The cells, collected from batch cultures, were maintained in a constant flow of medium, at an irradiance of 120 µmol m-2 s-1 and at 20 °C. Multiple internal reflections due to the micro fluidic channel were modeled, and showed that fringes are additive sinusoids to the pure absorption of the other components of the system. Preprocessing of the hyperspectral cube (x, y, Abs(λ)) included removing spectral fringe using an EMSC approach. Principal component analysis of the time series of hyperspectral cubes showed macromolecular pool variations (carbohydrates, lipids and DNA/RNA) of less than 2% after fringe correction.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...