Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Environ Monit Assess ; 189(9): 444, 2017 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-28795304

RESUMO

Liquid phase microextraction (LPME) has been widely used in extraction and preconcentration systems as an excellent alternative to conventional liquid phase extraction. In this work, a critical review is presented on liquid phase microextraction techniques used in the determination of cadmium in environmental samples. LPME techniques are classified into three main groups: single-drop liquid phase microextraction (SDME), hollow fiber liquid phase microextraction (HF-LPME), and dispersive liquid-liquid microextraction (DLLME). Methods involving these liquid phase microextraction techniques are described, addressing advantages and disadvantages, samples, figures of merit, and trends.


Assuntos
Cádmio/análise , Monitoramento Ambiental/métodos , Poluentes Ambientais/análise , Microextração em Fase Líquida/métodos , Meio Ambiente
2.
Talanta ; 61(5): 675-82, 2003 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-18969232

RESUMO

An on-line system for preconcentration and determination of copper at mug l(-1) level by flame atomic absorption spectrometry (FAAS) is proposed. Amberlite XAD-2 functionalized with 3,4-dihydroxybenzoic acid packed in a minicolumn was used as sorbent. Copper(II) ions were sorbed in the minicolumn, from which it could be eluted by hydrochloric acid solution directly to the nebulizer-burner system of the FAAS. Eluent solution was carried by water at a flow rate of 5.00 ml min(-1). Signals were measured as peak height by using an instrument software. Achieved sampling rate was 27 samples per hour. Analytical parameters were evaluated and the results demonstrated that copper can be determined, with acetate buffer to adjust the sample pH at 6.0, preconcentration time of 120 s and a sample flow rate of 6.50 ml min(-1). The desorption was carried out with 30 mul of a 1.0 mol l(-1) hydrochloric acid solution. An enrichment factor of 33 in 13.00 ml of sample (120 s preconcentration time) was achieved by using the time-based technique. The detection limit (DL) (3 s) was 0.27 mug l(-1) and the precision (assessed as the relative standard deviation) reached values of 5.7-1.1% in copper solutions of 5.00 to 50.00 mug l(-1) concentration, respectively. The accuracy of procedure was confirmed by copper determination in certified reference materials. Recoveries of spike additions (1.0 or 2.0 mug g(-1)) to food samples were quantitative (90.0-110.0%). These results proved also that the procedure is not affected by matrix interference and can be applied satisfactorily for copper determination in rice flour and starch samples.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...