Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
J Nucl Med ; 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38936975

RESUMO

Internal dosimetry supports safe and effective patient management during radionuclide therapy. Yet, it is associated with high clinical workload, costs, and patient burden, as patient scans at multiple time points (MTPs) must be acquired. Dosimetry based on imaging at a single time point (STP) has continuously gained popularity. However, MTP protocols, used as a reference to judge the validity of STP dosimetry, differ depending on local requirements and deviate from the unknown patient-specific ground truth pharmacokinetics. The aim of this study was to compare the error and optimum time point for different STP approaches using different reference MTP protocols. Methods: Whole-body SPECT/CT scans of 7 patients (7.4-8.9 GBq of [177Lu]Lu-PSMA-I&T) were scheduled at 24, 48, 72, and 168 h after injection. Sixty lesions, 14 kidneys, and 10 submandibular glands were delineated in the SPECT/CT data. Two curve models, that is, a mono- and a biexponential model, were fitted to the MTP data, in accordance with goodness-of-fit analysis (coefficients of variation, sum of squared errors). Three population-based STP approaches were compared: one method published by Hänscheid et al., one by Jackson et al., and one using population-based effective half-lives in the mono- or biexponential curve models. Percentage differences between STP and MTP dosimetry were evaluated. Results: Goodness-of-fit parameters show that a monoexponential function and a biexponential function with shared population-based parameters and physical tail are reasonable reference models. When comparing both reference models, we observed maximum differences of -44%, -19%, and -28% in the estimated absorbed doses for lesions, kidneys, and salivary glands, respectively. STP dosimetry with an average deviation of less than 10% from MTP dosimetry may be feasible; however, this deviation and the optimum imaging time point showed a dependence on the chosen reference protocol. Conclusion: STP dosimetry for [177Lu]Lu-PSMA therapy is promising to boost the integration of dosimetry into clinical routine. According to our patient cohort, 48 h after injection may be regarded as a compromise for STP dosimetry for lesions and at-risk organs. The results from this analysis show that a common gold standard for dosimetry is desirable to allow for reliable and comparable STP dosimetry.

2.
Eur J Nucl Med Mol Imaging ; 51(8): 2504-2514, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38512484

RESUMO

PURPOSE: Although 221Fr and 213Bi have sufficient gamma emission probabilities, quantitative SPECT after [225Ac]Ac-PSMA-I&T therapy remains challenging due to low therapeutic activities. Furthermore, 221Fr and 213Bi may underlie a different pharmacokinetics due to alpha recoil. We conducted a quantitative SPECT study and a urine analysis to investigate the pharmacokinetics of 221Fr and 213Bi and the impact on image-based lesion and kidney dosimetry. METHODS: Five patients (7.7 ± 0.2 MBq [225Ac]Ac-PSMA-I&T) underwent an abdominal SPECT/CT (1 h) at 24 and 48 h (Siemens Symbia T2, high-energy collimator, 440 keV/218 keV (width 20%), 78 keV (width 50%)). Quantitative SPECT was reconstructed using MAP-EM with attenuation and transmission-dependent scatter corrections and resolution modelling. Time-activity curves for kidneys (CT-based) and lesions (80% isocontour 24 h) were fitted mono-exponentially. Urine samples collected along with each SPECT/CT were measured in a gamma counter until secular equilibrium was reached. RESULTS: Mean kidney and lesion effective half-lives were as follows: 213Bi, 27 ± 6/38 ± 10 h; 221Fr, 24 ± 6/38 ± 11 h; 78 keV, 23 ± 7/39 ± 13 h. The 213Bi-to-221Fr kidney SUV ratio increased by an average of 9% from 24 to 48 h. Urine analysis revealed an increasing 213Bi-to-225Ac ratio (24 h, 0.98 ± 0.15; 48 h, 1.08 ± 0.09). Mean kidney and lesion absorbed doses were 0.17 ± 0.06 and 0.36 ± 0.1 Sv RBE = 5 /MBq using 221Fr and 213Bi SPECT images, compared to 0.16 ± 0.05/0.18 ± 0.06 and 0.36 ± 0.1/0.38 ± 0.1 Sv RBE = 5 /MBq considering either the 221Fr or 213Bi SPECT. CONCLUSION: SPECT/CT imaging and urine analysis showed minor differences of up to 10% in the daughter-specific pharmacokinetics. These variances had a minimal impact on the lesion and kidney dosimetry which remained within 8%.


Assuntos
Radiometria , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Masculino , Actínio/farmacocinética , Actínio/química , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Pessoa de Meia-Idade , Rim/diagnóstico por imagem , Rim/metabolismo , Idoso , Compostos Radiofarmacêuticos/farmacocinética , Glutamato Carboxipeptidase II/metabolismo , Radioisótopos/farmacocinética , Radioisótopos/uso terapêutico
3.
Eur J Nucl Med Mol Imaging ; 51(2): 395-404, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37796306

RESUMO

PURPOSE: A reliable method for regional in vivo imaging of radiation-induced cellular damage would be of great importance for the detection of therapy-induced injury to healthy tissue and the choice of adequate treatment of radiation emergency patients in both civilian and military events. This study aimed to investigate in a mouse model if positron emission tomography (PET) imaging with proliferation and apoptosis markers is potentially suitable for this purpose. METHODS: Four groups, including twenty mice (wild-type C57BL/6) each, were whole-body irradiated with 0 Gy, 0.5 Gy, 1 Gy, and 3 Gy and examined by PET over a six-month period at defined time points. 3'-[18F]fluoro-3'-deoxythymidine ([18F]FLT) and 2-(5-[18F]fluoropentyl)-2-methyl malonic acid ([18F]ML-10) were used to visualise proliferation and apoptosis. Regional standard uptake values were compared with respect to irradiation dose over time. Histologic data and peripheral blood cell values were correlated with the PET results. RESULTS: The hematopoietic bone marrow showed a significantly increased [18F]FLT signal at early time points after radiation exposure (day 3 and day 7). This correlated with blood parameters, especially leukocytes, and histological data. A significantly increased [18F]FLT signal also occurred in the gastrointestinal tract and thymus at early time points. An increased [18F]ML-10 signal related to irradiation doses was observed in the bone marrow on day 8, but there was a high variability of standard uptake values and no correlation with histological data. CONCLUSION: [18F]FLT showed potential to visualise the extent, regional distribution and recovery from radiation-induced cellular damage in the bone marrow, gastrointestinal tract and thymus. The potential of [18F]FLT imaging to assess the extent of bone marrow affected by irradiation might be especially useful to predict the subsequent severity of hematopoietic impairment and to adapt the therapy of the bone marrow reserve. [18F]ML-10 PET proved to be not sensitive enough for the reliable detection of radiation induced apoptosis.


Assuntos
Tomografia por Emissão de Pósitrons , Irradiação Corporal Total , Humanos , Camundongos , Animais , Irradiação Corporal Total/efeitos adversos , Camundongos Endogâmicos C57BL , Tomografia por Emissão de Pósitrons/métodos , Modelos Animais de Doenças , Proliferação de Células/efeitos da radiação , Apoptose , Didesoxinucleosídeos
4.
EJNMMI Phys ; 10(1): 53, 2023 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-37695374

RESUMO

AIM: Over recent years, [225Ac]Ac-PSMA and [177Lu]Lu-PSMA radiopharmaceutical therapy have evolved as a promising treatment option for advanced prostate cancer. Especially for alpha particle emitter treatments, there is still a need for improving dosimetry, which requires accurate values of relative biological effectiveness (RBE). To achieve that, consideration of DNA damages in the cell nucleus and knowledge of the energy deposition in the location of the DNA at the nanometer scale are required. Monte Carlo particle track structure simulations provide access to interactions at this level. The aim of this study was to estimate the RBE of 225Ac compared to 177Lu. The initial damage distribution after radionuclide decay and the residual damage after DNA repair were considered. METHODS: This study employed the TOol for PArtcile Simulation (TOPAS) based on the Geant4 simulation toolkit. Simulation of the nuclear DNA and damage scoring were performed using the TOPAS-nBio extension of TOPAS. DNA repair was modeled utilizing the Python-based program MEDRAS (Mechanistic DNA Repair and Survival). Five different cell geometries of equal volume and two radionuclide internalization assumptions as well as two cell arrangement scenarios were investigated. The radionuclide activity (number of source points) was adopted based on SPECT images of patients undergoing the above-mentioned therapies. RESULTS: Based on the simulated dose-effect curves, the RBE of 225Ac compared to 177Lu was determined in a wide range of absorbed doses to the nucleus. In the case of spherical geometry, 3D cell arrangement and full radionuclide internalization, the RBE based on the initial damage had a constant value of approximately 2.14. Accounting for damage repair resulted in RBE values ranging between 9.38 and 1.46 for 225Ac absorbed doses to the nucleus between 0 and 50 Gy, respectively. CONCLUSION: In this work, the consideration of DNA repair of the damage from [225Ac]Ac-PSMA and [177Lu]Lu-PSMA revealed a dose dependency of the RBE. Hence, this work suggested that DNA repair is an important aspect to understand response to different radiation qualities.

5.
EJNMMI Res ; 13(1): 78, 2023 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-37665396

RESUMO

BACKGROUND: Following resection and standard adjuvant radio- and chemotherapy, approved maintenance therapies for glioblastoma are lacking. Intracavitary radioimmunotherapy (iRIT) with 177Lu-labeled 6A10-Fab fragments targeting tumor-associated carbonic anhydrase XII and injected into the resection cavity offers a novel and promising strategy for improved tumor control. METHODS: Three glioblastoma patients underwent tumor resection followed by standard radio- and chemotherapy. These patients with stable disease following completion of standard therapy underwent iRIT on compassionate grounds. After surgical implantation of a subcutaneous injection reservoir with a catheter into the resection cavity, a leakage test with [99mTc]Tc-DTPA was performed to rule out leakage into other cerebral compartments. IRIT comprised three consecutive applications over three months for each patient, with 25%, 50%, 25% of the total activity injected. A dosimetry protocol was included with blood sampling and SPECT/CT of the abdomen to calculate doses for the bone marrow and kidneys as potential organs at risk. RESULTS: All three patients presented without relevant leakage after application of [99mTc]Tc-DTPA. Two patients underwent three full cycles of iRIT (592 MBq and 1228 MBq total activity). One patient showed histologically proven tumor progression after the second cycle (526 MBq total activity). No relevant therapy-associated toxicities or adverse events were observed. Dosimetry did not reveal absorbed doses above upper dose limits for organs at risk. CONCLUSIONS: In first individual cases, iRIT with [177Lu]Lu-6A10-Fab appears to be feasible and safe, without therapy-related side effects. A confirmatory multicenter phase-I-trial was recently opened and is currently recruiting.

6.
EJNMMI Phys ; 10(1): 11, 2023 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-36757516

RESUMO

BACKGROUND: 177Lu-PSMA therapy has been successfully used to prolong the survival of patients with metastatic castration-resistant prostate cancer. Patient-specific dosimetry based on serial quantitative SPECT/CT imaging can support the understanding of dose-effect relationships. However, multiple SPECT/CT measurements can be challenging for patients, which motivates the investigation of efficient sampling schedules and their impact on dosimetry. In this study, different time samplings with respect to the number and timing of SPECT/CT acquisitions with and without a late measurement were investigated. MATERIALS AND METHODS: In total, 43 lesions and 10 kidneys of 5 patients receiving 177Lu-PSMA-I&T therapy were investigated. Whole-body SPECT/CT measurements were performed at 1, 2, 3 and 7 days post-injection. For both lesions (isocontour-based segmentation) and kidneys (CT-based segmentation), a reference model was employed including all four time points. To identify the best-matching fit function out of a pre-defined set of models, visual inspection, coefficients of variation and sum of squared errors were considered as goodness-of-fit criteria. Biologically effective doses (BEDs) calculated with different time samplings (days 1, 2, 3/1, 2, 7/1, 3, 7/2, 3, 7 and 1, 2/1, 3/1, 7) were compared to the reference. RESULTS: The best-fit function was found to be a mono-exponential model for lesions and a bi-exponential model with a population-based parameter and two free parameters for kidneys. The BEDs calculated with the time sampling 1, 3, 7 days showed the lowest deviations from the reference for lesions with 4 ± 5%. Without day 7, still 86% of all lesions showed deviations from the reference < 10%. The outlier deviations showed a positive correlation with the effective half-life of the respective lesions. For kidneys, including days 1, 2, 3 achieved the best results with 0 ± 1%. Generally, deviations for kidneys were found to be small for all time samplings (max. 13%). CONCLUSIONS: For combined optimization of the SPECT/CT time sampling for kidney and lesion dosimetry during 177Lu-PSMA-I&T therapy, the sampling with days 1, 3, 7 showed the smallest deviation from the reference. Without a late acquisition, using the schedule with days 1, 2, 3 is likewise feasible.

7.
Eur J Nucl Med Mol Imaging ; 50(5): 1280-1290, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36629878

RESUMO

PURPOSE: Quantitative SPECT for patient-specific dosimetry is a valuable tool in the scope of radionuclide therapy, although its clinical application for 225Ac-based treatments may be limited due to low therapeutic activities. Therefore, the aim of this study was to demonstrate the feasibility of clinical quantitative low-count SPECT imaging during [177Lu]Lu-PSMA-I&T/[225Ac]Ac-PSMA-I&T treatment. METHODS: Eight prostate cancer patients (1000 MBq/8 MBq [177Lu]Lu-PSMA-I&T/[225Ac]Ac-PSMA-I&T) received a single-bed quantitative 177Lu/225Ac SPECT/CT acquisition (1 h) at 24 h post treatment (high-energy collimator, 16 projections p. head à 3.5 min, 128 × 128 pixel). The gamma peak at 440 keV (width: 10%) of the progeny 213Bi was imaged along with the peak at 208 keV (width: 15%) of 177Lu. Quantification included CT-based attenuation and window-based scatter correction plus resolution modelling. Gaussian post-filtering with a full-width-half-maximum of 30 mm and 40-45 mm was employed to match the signal-to-noise ratio of 225Ac and 177Lu, respectively. RESULTS: Kidney (r = 0.96, p < 0.01) and lesion (r = 0.94, p < 0.01) SUV for [177Lu]Lu-PSMA-I&T and [225Ac]Ac-PSMA-I&T showed a strong and significant correlation. Kidney SUV were significantly higher (p < 0.01) for [225Ac]Ac-PSMA-I&T (2.5 ± 0.8 vs. 2.1 ± 0.9), while for [177Lu]Lu-PSMA-I&T lesion SUV were significantly higher (p = 0.03; 1.8 ± 1.1 vs. 2.1 ± 1.5). For absorbed dose estimates, significant differences regarding the kidneys remained, while no significant differences for lesion dosimetry were found. CONCLUSION: Quantitative low-count SPECT imaging of the peak at 440 keV during [225Ac]Ac-PSMA-I&T therapy is feasible. Multi-isotope imaging for [177Lu]Lu-PSMA-I&T/[225Ac]Ac-PSMA-I&T therapy indicates accumulation of free 213Bi in the kidneys.


Assuntos
Neoplasias de Próstata Resistentes à Castração , Compostos Radiofarmacêuticos , Humanos , Masculino , Dipeptídeos/uso terapêutico , Compostos Heterocíclicos com 1 Anel/uso terapêutico , Isótopos , Antígeno Prostático Específico , Neoplasias de Próstata Resistentes à Castração/diagnóstico por imagem , Neoplasias de Próstata Resistentes à Castração/radioterapia , Neoplasias de Próstata Resistentes à Castração/tratamento farmacológico , Compostos Radiofarmacêuticos/uso terapêutico , Distribuição Tecidual , Tomografia Computadorizada de Emissão de Fóton Único
8.
J Nucl Med ; 64(5): 767-774, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36657980

RESUMO

Radiopharmaceutical therapies (RPTs) with 177Lu-prostate-specific membrane antigen (PSMA) ligands have demonstrated promising results for the treatment of metastatic castration-resistant prostate cancer. The lack of absorbed-dose-effect relationships currently prevents patient-specific activity personalization. To ease the implementation of dosimetry in the routine clinical workflow for RPT, simplified methods such as single-time-point (STP) instead of multiple-time-point (MTP) imaging protocols are required. This work aimed at assessing differences in the time-integrated activity (TIA) of STP versus MTP image-based dosimetry for 177Lu-PSMA-617 therapy. Methods: Twenty metastatic castration-resistant prostate cancer patients with MTP quantitative 177Lu-SPECT imaging data (∼24, 48, and 72 h post injection (p.i.)) available on first and second 177Lu-PSMA-617 therapy cycles were included in this study. Time-activity curves were fitted for kidneys and lesions to derive effective half-lives and yield a reference TIA. STP approaches involved the formula by Hänscheid (STPH) and a prior-information method (STPprior) that uses the effective half-lives from the first therapy cycle. All time points were considered for the STP approaches. Percentage differences (PDs) in TIA between STP and MTP were compared for the second therapy cycle. Results: Using STPH at 48 h p.i. for kidneys showed a -1.3% ± 5.6% PD from MTP, whereas STPprior showed a PD of 4.6% ± 6.2%. The smallest average PDs for the 56 investigated individual lesions were found using STPprior at 48 h p.i., at only 0.4% ± 14.9%, whereas STPH at 72 h p.i. had a smallest PD of -1.9% ± 14.8%. Conclusion: STP dosimetry for 177Lu-PSMA-617 therapy using a single SPECT/CT scan at 48 or 72 h p.i. is feasible, with a PD of less than ±20% compared with MTP. The validity of both STPH and STPprior has been demonstrated. We believe this finding can increase the adoption of dosimetry and facilitate implementation in routine clinical RPT workflows. Doing so will ultimately enable the finding of dose-effect relationships based on fixed therapy activities that may, in future, allow for absorbed-dose-based RPT activity personalization.


Assuntos
Neoplasias de Próstata Resistentes à Castração , Masculino , Humanos , Neoplasias de Próstata Resistentes à Castração/patologia , Dipeptídeos/uso terapêutico , Antígeno Prostático Específico , Compostos Heterocíclicos com 1 Anel/uso terapêutico , Compostos Radiofarmacêuticos/uso terapêutico , Lutécio/uso terapêutico
9.
Q J Nucl Med Mol Imaging ; 67(2): 174-179, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34477347

RESUMO

BACKGROUND: The most important cause of heart transplant loss is early acute allograft rejection, caused by the infiltration of lymphocytes, development of edema and myocardial necrosis. It has been propagated that [68Ga]DOTA-TATE PET might be suitable to quantify the presence of SSTR over-expressing lymphocytes. With heterotopic allogenic heart transplant models in the rat readily available, we aimed to investigate, if monitoring and quantification of acute allograft rejection after heterotopic allogenic heart transplantation was feasible by non-invasive serial [68Ga]DOTA-TATE PET. METHODS: Seventeen Lewis rats (9 for serial PET imaging, 8 for histological correlation) received allogenic heterotopic heart transplants from 17 Brown-Norway rats. On days 4, 6 and 7 a [68Ga]DOTA-TATE PET scan was performed. RESULTS: Imaging of acute transplant rejection until 7 days after allogenic heart transplantation in the rat is feasible. Heterotopic allografts showed significantly increased tracer uptake on day 4 until day 7 after transplantation, reflecting the process of histologically detected myocardial lymphocytic infiltration. Both the area of infarction and the amount of necrosis increased over the course of 7 days, with necrosis reaching statistical significance. CONCLUSIONS: We purport that the detected PET signal is primarily a specific marker of lymphocyte infiltration and only to a lesser extent an unspecific marker of infarction and necrosis. Thus, [68Ga]DOTA-TATE PET might be a suitable tool for serial imaging and quantification of lymphocyte infiltration as a direct mediator of acute allograft rejection at an early stage after heart transplantation.


Assuntos
Rejeição de Enxerto , Transplante de Coração , Ratos , Humanos , Animais , Projetos Piloto , Rejeição de Enxerto/diagnóstico por imagem , Rejeição de Enxerto/patologia , Ratos Endogâmicos Lew , Transplante de Coração/efeitos adversos , Tomografia por Emissão de Pósitrons , Aloenxertos , Infarto , Necrose
10.
Biomedicines ; 10(12)2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36551858

RESUMO

Therapy options for advanced pancreatic neuroendocrine tumors (pNETs) include the mTOR inhibitor everolimus and peptide receptor radionuclide therapy (PRRT) with [177Lu]Lu-DOTA-TATE, however further optimization in the therapeutic landscape is required as response rates are still low. In this study, we investigated the synergistic and potentially enhanced efficacy of a combined treatment with everolimus and [177Lu]Lu-DOTA-TATE in a mouse model. Baseline [68Ga]Ga-DOTA-TATE PET scans were obtained five days after athymic CD1 mice were inoculated with AR42J tumor cells, before separating the animals into four groups. Group 1 received a placebo, group 2 everolimus, group 3 a placebo and PRRT, and group 4 everolimus and PRRT. The treatment response was monitored by manually measuring the tumor volumes (manual tumor volume, MTV) and conducting sequential [68Ga]Ga-DOTA-TATE PET scans at one, two, and four weeks after treatment induction. The biological tumor volume (BTV) was derived from PET scans using threshold-based volume of interest (VOI) measurements. Tracer uptake was measured semi-quantitatively as a tumor to background ratio (TBR). Mice were euthanized due to excessive tumor growth according to the ethics protocol; blood samples were drawn for the preparation of full blood counts and kidneys were obtained for histological analysis. For the histological assessment, a standardized score (renal damage score, RDS) was used. Full blood counts showed significantly increased numbers of neutrophils and lymphocytes in the groups receiving PRRT. All other parameters did not differ relevantly. In the histological analysis, groups receiving PRRT had a significantly higher RDS, whereas everolimus only tended to cause an increase in the RDS. Mice in groups 1 and 2 had to be euthanized due to excessive tumor growth two weeks after the start of the therapy, whereas follow-up in groups 3 and 4 comprised four weeks. PRRT significantly inhibited tumor growth; the administration of everolimus did not induce an additional effect. A good correlation existed between MTV and BTV. PRRT significantly reduced the TBR. [68Ga]Ga-DOTA-TATE PET is suitable for monitoring tumor growth in the applied model. The high efficacy of [177Lu]Lu-DOTA-TATE is not enhanced by the combination with everolimus.

11.
Diagnostics (Basel) ; 11(3)2021 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-33802417

RESUMO

BACKGROUND: Dosimetry can tailor prostate-specific membrane-antigen-targeted radioligand therapy (PSMA-RLT) for metastatic castration-resistant prostate cancer (mCRPC). However, whole-body tumor dosimetry is challenging in patients with a high tumor burden. We evaluate a simplified index-lesion-based single-photon emission computed tomography (SPECT) dosimetry method in correlation with clinical outcome. METHODS: 30 mCRPC patients were included (median 71 years). The dosimetry was performed for the first cycle using quantitative 177Lu-SPECT. The response was evaluated using RECIST 1.1 and PERCIST criteria, as well as changes in PSMA-positive tumor volume (PSMA-TV) in post-therapy PSMA-PET and biochemical response according to PSA changes after two RLT cycles. RESULTS: Mean tumor doses as well as index-lesion doses were significantly higher in PERCIST responders compared to non-responders (10.2 ± 12.0 Gy/GBq vs. 4.0 ± 2.9 Gy/GBq, p = 0.03 and 13.7 ± 14.2 Gy/GBq vs. 5.9 ± 4.4 Gy/GBq, p = 0.04, respectively). No significant differences in mean tumor and index lesion doses were observed between responders and non-responders according to RECIST 1.1, PSMA-TV, and biochemical response criteria. CONCLUSION: Compared to mean tumor doses on a patient level, single index-lesion-based SPECT dosimetry correlates equally well with the response to PSMA-RLT according to PERCIST criteria and may represent a fast and feasible dosimetry approach for clinical routine.

13.
Eur J Nucl Med Mol Imaging ; 48(11): 3571-3581, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33928401

RESUMO

PURPOSE: Radiolabelled somatostatin analogues targeting somatostatin receptors (SSR) are well established for combined positron emission tomography/computer tomography (PET/CT) imaging of neuroendocrine tumours (NET). [18F]SiTATE has recently been introduced showing high image quality, promising clinical performance and improved logistics compared to the clinical reference standard 68Ga-DOTA-TOC. Here we present the first dosimetry and optimal scan time analysis. METHODS: Eight NET patients received a [18F]SiTATE-PET/CT (250 ± 66 MBq) with repeated emission scans (10, 30, 60, 120, 180 min after injection). Biodistribution in normal organs and SSR-positive tumour uptake were assessed. Dosimetry estimates for risk organs were determined using a combined linear-monoexponential model, and by applying 18F S-values and reference target masses for the ICRP89 adult male or female (OLINDA 2.0). Tumour-to-background ratios were compared quantitatively and visually between different scan times. RESULTS: After 1 h, normal organs showed similar tracer uptake with only negligible changes until 3 h post-injection. In contrast, tracer uptake by tumours increased progressively for almost all types of metastases, thus increasing tumour-to-background ratios over time. Dosimetry resulted in a total effective dose of 0.015 ± 0.004 mSv/MBq. Visual evaluation revealed no clinically relevant discrepancies between later scan times, but image quality was rated highest in 60 and 120 min images. CONCLUSION: [18F]SiTATE-PET/CT in NET shows overall high tumour-to-background ratios from 60 to 180 min after injection and an effective dose comparable to 68Ga-labelled alternatives. For clinical use of [18F]SiTATE, the best compromise between image quality and tumour-to-background contrast is reached at 120 min, followed by 60 min after injection.


Assuntos
Tumores Neuroendócrinos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adulto , Computadores , Feminino , Humanos , Masculino , Tumores Neuroendócrinos/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Radiometria , Distribuição Tecidual
14.
EJNMMI Phys ; 8(1): 26, 2021 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-33709253

RESUMO

BACKGROUND: Patients with metastatic, castration-resistant prostate cancer (mCRPC) present with an increased tumor burden in the skeleton. For these patients, Lutetium-177 (Lu-177) radioligand therapy targeting the prostate-specific membrane antigen (PSMA) has gained increasing interest with promising outcome data. Patient-individualized dosimetry enables improvement of therapy success with the aim of minimizing absorbed dose to organs at risk while maximizing absorbed dose to tumors. Different dosimetric approaches with varying complexity and accuracy exist for this purpose. The Medical Internal Radiation Dose (MIRD) formalism applied to tumors assumes a homogeneous activity distribution in a sphere with unit density for derivation of tumor S values (TSV). Voxel S value (VSV) approaches can account for heterogeneous activities but are simulated for a specific tissue. Full patient-individual Monte Carlo (MC) absorbed dose simulation addresses both, heterogeneous activity and density distributions. Subsequent CT-based density weighting has the potential to overcome the assumption of homogeneous density in the MIRD formalism with TSV and VSV methods, which could be a major limitation for the application in bone metastases with heterogeneous density. The aim of this investigation is a comparison of these methods for bone lesion dosimetry in mCRPC patients receiving Lu-177-PSMA therapy. RESULTS: In total, 289 bone lesions in 15 mCRPC patients were analyzed. Percentage difference (PD) of average absorbed dose per lesion compared to MC, averaged over all lesions, was + 14 ± 10% (min: - 21%; max: + 56%) for TSVs. With lesion-individual density weighting using Hounsfield Unit (HU)-to-density conversion on the patient's CT image, PD was reduced to - 8 ± 1% (min: - 10%; max: - 3%). PD on a voxel level for three-dimensional (3D) voxel-wise dosimetry methods, averaged per lesion, revealed large PDs of + 18 ± 11% (min: - 27%; max: + 58%) for a soft tissue VSV approach compared to MC; after voxel-wise density correction, this was reduced to - 5 ± 1% (min: - 12%; max: - 2%). CONCLUSION: Patient-individual MC absorbed dose simulation is capable to account for heterogeneous densities in bone lesions. Since the computational effort prevents its routine clinical application, TSV or VSV dosimetry approaches are used. This study showed the necessity of lesion-individual density weighting for TSV or VSV in Lu-177-PSMA therapy bone lesion dosimetry.

15.
J Nucl Med ; 62(7): 1006-1011, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33127625

RESUMO

Because of challenges in performing routine personalized dosimetry in radiopharmaceutical therapies, interest in single-time-point (STP) dosimetry, particularly using only a single SPECT scan, is on the rise. Meanwhile, there are questions about the reliability of STP dosimetry, with limited independent validations. In the present work, we analyzed 2 STP dosimetry methods and evaluated dose errors for several radiopharmaceuticals based on effective half-life distributions. Methods: We first challenged the common assumption that radiopharmaceutical effective half-lives across the population are gaussian-distributed (i.e., follow a normal distribution). Then, dose accuracy was estimated using 2 STP dosimetry methods for a wide range of potential post injection (p.i.) scan time points for different radiopharmaceuticals applied to neuroendocrine tumors and prostate cancer. The accuracy and limitations of each of the STP methods were discussed. Results: A lognormal distribution was more appropriate for capturing effective half-life distributions. The STP framework was promising for dosimetry of 177Lu-DOTATATE and for kidney dosimetry of different radiopharmaceuticals (errors < 30%). Meanwhile, for some radiopharmaceuticals, STP accuracy was compromised (e.g., in bone marrow and tumors for 177-labeled prostate-specific membrane antigen [PSMA])). The optimal SPECT scanning time for 177Lu-DOTATATE was approximately 72 h p.i., whereas 48 h p.i. was better for 177Lu-PSMA. Conclusion: Simplified STP dosimetry methods may compromise the accuracy of dose estimates, with some exceptions, such as for 177Lu-DOTATATE and for kidney dosimetry in different radiopharmaceuticals. Simplified personalized dosimetry in the clinic continues to be challenging. On the basis of our results, we make suggestions and recommendations for improved personalized dosimetry using simplified imaging schemes.


Assuntos
Compostos Radiofarmacêuticos , Estudos de Viabilidade , Humanos , Tomografia por Emissão de Pósitrons , Cintilografia
17.
Cancers (Basel) ; 14(1)2021 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-35008218

RESUMO

In this study, dual PET and contrast enhanced MRI were combined to investigate their correlation per voxel in patients at initial diagnosis with suspected glioblastoma. Correlation with contrast enhancement (CE) as an indicator of BBB leakage was further used to evaluate whether PET signal is likely caused by BBB disruption alone, or rather attributable to specific binding after BBB passage. PET images with [18F]GE180 and the amino acid [18F]FET were acquired and normalized to healthy background (tumor-to-background ratio, TBR). Contrast enhanced images were normalized voxel by voxel with the pre-contrast T1-weighted MRI to generate relative CE values (rCE). Voxel-wise analysis revealed a high PET signal even within the sub-volumes without detectable CE. No to moderate correlation of rCE with TBR voxel-values and a small overlap as well as a larger distance of the hotspots delineated in rCE and TBR-PET images were detected. In contrast, voxel-wise correlation between both PET modalities was strong for most patients and hotspots showed a moderate overlap and distance. The high PET signal in tumor sub-volumes without CE observed in voxel-wise analysis as well as the discordant hotspots emphasize the specificity of the PET signals and the relevance of combined differential information from dual PET and MRI images.

18.
J Nucl Med ; 62(5): 669-674, 2021 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-33008928

RESUMO

Treatment of advanced metastatic castration-resistant prostate cancer after failure of approved therapy options remains challenging. Prostate-specific membrane antigen (PSMA)-targeting ß- and α-emitters have been introduced, with promising response rates. Here, we present the first-to our knowledge-clinical data for PSMA-targeted α-therapy (TAT) using 225Ac-PSMA imaging and therapy (I&T). Methods: Fourteen patients receiving 225Ac-PSMA-I&T were included in this retrospective analysis. Eleven of the 14 had prior second-line antiandrogen treatment with abiraterone or enzalutamide, prior chemotherapy, and prior 177Lu-PSMA treatment. Patients were treated at bimonthly intervals until progression or intolerable side effects. Prostate-specific antigen (PSA) was measured for response assessment. Hematologic and nonhematologic side effects were recorded according to the Common Terminology Criteria for Adverse Events, version 5.0. Results: Thirty-four cycles of 225Ac-PSMA-I&T were applied (median dose, 7.8 MBq; range, 6.0-8.5), with 1 cycle in 3 patients, 2 cycles in 7 patients, 4 cycles in 3 patients, and 5 cycles in 1 patient. No acute toxicity was observed during hospitalization. Baseline PSA was 112 ng/mL (range, 20.5-818 ng/mL). The best PSA response after TAT (a PSA decline ≥ 50%) was observed in 7 patients, and a PSA decline of any amount was observed in 11 patients. Three patients had no PSA decline at any time. A subgroup analysis of 11 patients with prior 177Lu-PSMA treatment showed any PSA decline in 8 patients and a decline of at least 50% in 5 patients. After TAT, grade 3 anemia was observed in 3 of the 14 patients, with 2 of them presenting with grade 2 anemia already at baseline. Grade 3 leukopenia was observed in 1 patient. Eight patients with preexisting xerostomia after 177Lu-PSMA showed no worsening after TAT. Newly diagnosed grade 1 or 2 xerostomia after TAT was observed in 5 patients. One patient reported no xerostomia at all. Conclusion: Our first clinical data for TAT using 225Ac-PSMA-I&T showed a promising antitumor effect in advanced metastatic castration-resistant prostate cancer. These results are highly comparable to data on 225Ac-PSMA-617 TAT.


Assuntos
Actínio/uso terapêutico , Antígenos de Superfície/metabolismo , Partículas beta/uso terapêutico , Glutamato Carboxipeptidase II/metabolismo , Neoplasias de Próstata Resistentes à Castração/diagnóstico por imagem , Neoplasias de Próstata Resistentes à Castração/radioterapia , Humanos , Masculino , Pessoa de Meia-Idade , Terapia de Alvo Molecular , Metástase Neoplásica , Neoplasias de Próstata Resistentes à Castração/patologia , Estudos Retrospectivos , Resultado do Tratamento
19.
Phys Med ; 80: 317-326, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33248338

RESUMO

BACKGROUND: To improve therapy outcome of Yttrium-90 selective internal radiation therapy (90Y SIRT), patient-specific post-therapeutic dosimetry is required. For this purpose, various dosimetric approaches based on different available imaging data have been reported. The aim of this work was to compare post-therapeutic 3D absorbed dose images using Technetium-99m (99mTc) MAA SPECT/CT, Yttrium-90 (90Y) bremsstrahlung (BRS) SPECT/CT, and 90Y PET/CT. METHODS: Ten SIRTs of nine patients with unresectable hepatocellular carcinoma (HCC) were investigated. The 99mTc SPECT/CT data, obtained from 99mTc-MAA-based treatment simulation prior to 90Y SIRT, were scaled with the administered 90Y therapy activity. 3D absorbed dose images were generated by dose kernel convolution with scaled 99mTc/90Y SPECT/CT, 90Y BRS SPECT/CT, and 90Y PET/CT data of each patient. Absorbed dose estimates in tumor and healthy liver tissue obtained using the two SPECT/CT methods were compared against 90Y PET/CT. RESULTS: The percentage deviation of tumor absorbed dose estimates from 90Y PET/CT values was on average -2 ± 18% for scaled 99mTc/90Y SPECT/CT, whereas estimates from 90Y BRS SPECT/CT differed on average by -50 ± 13%. For healthy liver absorbed dose estimates, all three imaging methods revealed comparable values. CONCLUSION: The quantification capabilities of the imaging data influence 90Y SIRT tumor dosimetry, while healthy liver absorbed dose values were comparable for all investigated imaging data. When no 90Y PET/CT image data are available, the proposed scaled 99mTc/90Y SPECT/CT dosimetry method was found to be more appropriate for HCC tumor dosimetry than 90Y BRS SPECT/CT based dosimetry.


Assuntos
Carcinoma Hepatocelular , Embolização Terapêutica , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/radioterapia , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Microesferas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Agregado de Albumina Marcado com Tecnécio Tc 99m , Tomografia Computadorizada de Emissão de Fóton Único , Radioisótopos de Ítrio/uso terapêutico
20.
EJNMMI Res ; 10(1): 41, 2020 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-32335736

RESUMO

PURPOSE: Peptide receptor radionuclide therapy (PRRT) with [177Lu]Lu-DOTA0,TYR3-octreotate ([177Lu]Lu-DOTA-TATE) and the mechanistic target of rapamycin (mTOR) inhibitor everolimus are both approved for the treatment of neuroendocrine tumours (NET). However, tumour progression is still frequent, and treatment strategies need further improvement. One possible approach could be to combine different therapy options. In this study, we investigated the toxicity of a combined treatment with everolimus and [177Lu]Lu-DOTA-TATE in female Lewis rats. METHODS: Animals received 200 MBq of [177Lu]Lu-DOTA-TATE once and/or 5 mg/kg body weight everolimus or placebo weekly for 16 weeks and were divided into four groups (group 1, placebo; group 2, everolimus; group 3, placebo + [177Lu]Lu-DOTA-TATE; group 4, everolimus + [177Lu]Lu-DOTA-TATE). Blood levels of creatinine and blood urea nitrogen (BUN) were assessed weekly to monitor nephrotoxicity, and a full blood count was performed at the time of euthanasia to monitor myelotoxicity. Additionally, renal function was analysed by sequential [99mTc]Tc-mercaptoacetyltriglycine ([99mTc]Tc-MAG3) scintigraphies. Histopathological examination was performed in all the kidneys using a standardized renal damage score (RDS). RESULTS: Rats receiving everolimus showed a significantly lower increase in creatinine levels than those receiving placebo. Everolimus therapy reduced white blood count significantly, which was not observed for [177Lu]Lu-DOTA-TATE. Functional renal scintigraphies using [99mTc]Tc-MAG3 showed a compromised initial tracer uptake after PRRT and slower but still preserved excretion after everolimus. Histology showed no significant RDS differences between groups. CONCLUSION: Renal scintigraphy is a highly sensitive tool for the detection of renal function impairment after a combination of everolimus and PRRT. Additional treatment with everolimus does not increase renal and haematological toxicity of PRRT with [177Lu]Lu-DOTA-TATE.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...