Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Control Release ; 285: 96-105, 2018 09 10.
Artigo em Inglês | MEDLINE | ID: mdl-29964137

RESUMO

A 2-dimensional high-throughput screening method is presented to select peptide sequences from large peptide libraries for precision formulation additives, having a high capacity to specifically host a drug of interest and provide tailored drug release properties. The identified sequences are conjugated with poly(ethylene glycol) (PEG) to obtain peptide-PEG conjugates that proved to be valuable as solubilizers for small organic molecule drugs to overcome limitations of poor water-solubility and low bio-availability. The 2D-screening method selects peptide sequences on both (i) high loading capacities and (ii) preferred drug-release capabilities as demonstrated on an experimental Tau-protein aggregation inhibitor/Tau- deaggregator with potentials for an anti-Alzheimer disease drug (BB17). To enable 2D-screening, a one-bead one-compound (OBOC) peptide library was immobilized on a glass slide, allocating individual beads to permanent positions. While the first screening step involved incubation of the supported OBOC library with BB17 to identify beads with high drug binding capacities by fluorescence scanner readouts, the second step reveals release properties of the high capacity binders by incubation with blood plasma protein model solutions. Efficiently peptides with high BB17 capacities and either keeper or medium or fast releaser properties can be identified by direct sequence readouts from the glass slide supported resin beads via matrix-assisted laser desorption/ionization time-of-flight tandem mass spectrometry. Four peptides are synthesized as peptide-PEG solubilizers representing strong, medium, weak releasers and non-binders. Loading capacities reached up to 1:3.4 (mol drug per mol carrier) and release kinetics (fast/medium/slow) are in agreement with the selection process as investigated by fluorescence anisotropy and fluorescence correlation spectroscopy. The ability of BB17/conjugate complexes to inhibit the aggregation of Tau4RDΔK (four repeat Tau ((M)Q244-E372 with deletion of K280), 129 residues) in N2a cells is studied by a Tau-pelleting assay showing the modulation of cellular Tau aggregation. Promising effects such as the reduction of 55% of total Tau load are observed for the strong releaser additive. Studies of in vitro Thioflavin S Tau-aggregation assays show half-maximal inhibitory activities (IC50 values) of BB17/conjugates in the low micro-molar range.


Assuntos
Portadores de Fármacos/química , Peptídeos/química , Composição de Medicamentos , Liberação Controlada de Fármacos , Humanos , Modelos Moleculares , Biblioteca de Peptídeos , Preparações Farmacêuticas/administração & dosagem , Polietilenoglicóis/química , Solubilidade , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
2.
Soft Matter ; 14(11): 1992-1995, 2018 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-29493687

RESUMO

Peptide-polymer conjugates are applied as interface stabilizers that are precisely tuned to recognize the surfaces of inorganic constituents in composites. A set of peptide sequences is usually selected through phage-display and a strategy is presented for the identification of the most effective sequences through the evaluation of secondary interactions, including not only surface binding but also solubility and self-aggregation tendency.

3.
Chem Commun (Camb) ; 53(3): 593-596, 2017 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-27981331

RESUMO

An efficient and easy route towards triazolinedione (TAD) endcapped peptides is described, in which a TAD-precursor was coupled to N-terminal amines on a solid support. Modified peptides readily reacted with diene end-functionalized poly(ε-caprolactone) of different molecular weights. The ligation proved to be orthogonal to a variety of functional groups present in natural amino acids.


Assuntos
Peptídeos/química , Triazóis/química , Peso Molecular , Poliésteres/química
4.
Eur Phys J E Soft Matter ; 29(1): 73-85, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19418079

RESUMO

We prepared dense films of adsorbed brush-like macromolecules on mica substrate by transfer of compressed Langmuir monolayers from water subphase. The main macromolecular contours in the dense films were clearly resolved by SFM. The films were subjected to successive treatments by ethanol and water vapours. In accordance with previous results for isolated macromolecules, the films underwent collapse and subsequent decollapse morphological transformations in the changing vapour environment. Statistical analysis of the macromolecular dimensions in the films allowed us to measure the values of the scaling exponent nu determining the correlation between mean lateral and linear dimensions of the macromolecules. The analysis showed that the macromolecular conformations in the film as transferred were similar to the previously described conformations of the same macromolecules deposited directly on mica as isolated chains at much lower surface densities. The determined nu was close to the 0.75 value corresponding to the 2D SAW statistics. We assumed that the molecules retained the high degree of extension during the compression step due to suppressed reorganisation of the side chains. Differently from previous observations for isolated macromolecules, the restored conformations in the dense films after collapse-decollapse cycle were more extended with the nu of about 0.73 value. A theoretical explanation of the high degree of re-extension is proposed.


Assuntos
Substâncias Macromoleculares/química , Acrilatos/química , Adsorção , Microscopia de Força Atômica , Modelos Moleculares , Ácidos Polimetacrílicos/química , Volatilização
6.
J Res Natl Inst Stand Technol ; 110(3): 263-7, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308133

RESUMO

We studied the neutron quantum states in the potential well formed by the Earth's gravitational field and a horizontal mirror. The estimated characteristic sizes of the neutron wave functions in two lowest quantum states correspond to their expectations with an accuracy of ≈25 %. The spatial density distribution in a standing neutron wave above a mirror was measured for a set of a few lowest quantum states. A position-sensitive neutron detector with an extra high spatial resolution of 1 µm to 2 µm was developed and tested for this particular task. Although this experiment was not designed or optimized to search for an additional short-range force, nevertheless it allowed us to slightly improve the published boundary in the nanometer range of characteristic distances. We studied systematical uncertainties in the chosen "flow-through" method as well as the feasibility to improve further the accuracy in this experiment.

7.
J Microsc ; 215(Pt 3): 245-56, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15312190

RESUMO

We describe a technique to visualize and effect in real time motion and conformational transitions of single macromolecules. Two steps are involved. First, scanning force microscopy (SFM) was applied to detect in situ conformational transitions of single polymer molecules adsorbed on a substrate surface. Secondly, these changes were induced by controlled variations of environmental conditions in a microscope environmental chamber. In particular, we have revealed that exposure of a substrate with adsorbed macromolecules to vapours of different nature was able to increase molecular mobility and to stimulate conformational transitions of the polymer chains on the surface. Realization of SFM observation in a variable vapour environment was not as difficult as in liquid media. Variations of the vapour composition affected the oscillation dynamics of the cantilever with the scanning probe only to a small extent, and did not impede continuation of the scanning procedure. In fact, the characteristic times of the observed conformational changes were large enough (minutes to dozens of minutes) for sampling images repeatedly. Although recording of an SFM image was slow and required several minutes, we were able to visualize step-by-step the successive stages of the slow conformational transformation of the macromolecules adhering to the substrate, i.e. to investigate a molecular response to the environment changes in real time. Here, we studied the reversible collapse-decollapse transitions of cylindrical poly(methacrylate)-graft-poly(n-butyl acrylate) brush-like macromolecules exposed to different vapours. Single macromolecules on mica tended to assume a compacted globular conformation when exposed to the vapour of compounds, which due to their amphiphilic nature adsorb on mica and lower the surface energy of the substrate (e.g. alcohols). By contrast, the macromolecules adopted extended two-dimensional worm-like conformations in the vapours of compounds having high values of surface tension (such as water). In our opinion, the reason for the observed tendency was a competition in spreading on the substrate surface between the macromolecules and the co-adsorbed vapour molecules. If the brush-like macromolecules succeeded in the spreading, they acquired an extended conformation. Otherwise they collapsed to globuli in order to reduce the surface area per macromolecule. Thus, the enhanced mobility of synthetic macromolecules on a substrate observed in a vapour environment in combination with the possibility to manipulate the macromolecular conformation via changes in a vapour phase and the ability to visualize the transitions of the macromolecules individually, provides challenging prospects for SFM studies on the dynamics of single molecules under applied external stimuli.

8.
J Res Natl Inst Stand Technol ; 105(1): 25-32, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-27551584

RESUMO

In the GRID technique one measures Doppler-broadened line profiles of γ transitions using the high resolution crystal spectrometers GAMS, which are installed at the high flux reactor of the ILL Grenoble. One of the essential applications of this technique is the measurement of nuclear state lifetimes. In the present contribution the precision and the principal limits of the technique are discussed.

9.
J Res Natl Inst Stand Technol ; 105(1): 81-7, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-27551590

RESUMO

Crystal-GRID measurements have been performed with ZnS single crystals. For the first time, an asymmetric Crystal-GRID line shape could be observed. The preliminary data evaluation indicates that the reported lifetime of the 3221 keV level in (33)S is too short. A value of about 60 fs has been found. Due to this "long" lifetime the line shape is much less structured than calculated with the reported lifetime.

10.
J Res Natl Inst Stand Technol ; 105(1): 71-80, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-27551589

RESUMO

The Crystal-GRID method is used to study interatomic collisions at low energy in metals and such to probe the repulsive interatomic potential. Line shapes of gamma rays, emitted by the recoiling (59)Ni isotope after thermal neutron capture in Ni single crystals, were measured and compared to results obtained by molecular dynamics simulations of the slowing down. The same procedure is also used for recoiling (57)Fe and (54)Cr atoms in Fe and Cr single crystals, respectively. Different potentials (including several from the embedded atom method) are investigated using the observed fine structure of the line shape which depends on the crystal orientations. From the detailed study of the lineshapes measured in two different orientations, a new potential is then derived for each element. Nuclear state lifetimes for the excited isotopes are also deduced with a higher precision than obtained with standard nuclear techniques.

11.
J Res Natl Inst Stand Technol ; 105(1): 125-31, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-27551596

RESUMO

Lifetimes of levels from K(π) = 2(+), K(π) = 4(+) and several K(π) = 0(+) bands have been measured in the (178)Hf nucleus using the GRID technique. Lifetimes of the 2(+) and 3(+) levels were measured within the K(π) = 2(+) γ band. A lower limit was established for the lifetime of the 4(+) level of the K(π) = 4(+) band. The resulting upper limits for the absolute B(E2) values exclude collective transitions from the K(π) = 4(+) to the ground state band but not to the K(π)= 2(+) band. Level lifetimes were also measured for several states within three separate K(π)= 0(+) bands. Evidence is presented for a previously unobserved case of two excited K(π)= 0(+) bands being connected via collective E2 transitions.

12.
J Res Natl Inst Stand Technol ; 105(1): 167-71, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-27551603

RESUMO

The construction of the double-crystal γ-spectrometer GAMS5 was finished recently and the instrument is now operational. Measurements with double flat crystals were carried out and we will report here on the progress concerning the characteristics of the spectrometer.

13.
J Res Natl Inst Stand Technol ; 105(1): 177-82, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-27551605

RESUMO

The application of GRID (Gamma Ray Induced Doppler broadening) spectroscopy to the localization of foreign atoms in single crystals is demonstrated on erbium in YAP. By the investigation of the Doppler broadened secondary γ line for two crystalline directions, the Er was determined to be localized on the Y site. Conditions for the nuclear parameters of the impurity atoms used for the application of GRID spectroscopy are discussed.

14.
Z Kardiol ; 88(12): 1028-33, 1999 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-10654395

RESUMO

An echinococcal cyst of the heart is a rare cause of acute cardiac tamponade. We report on a 24 year old male from the Kosovo who was brought in an emergency state from a provincial hospital complaining of severe dyspnea, thoracic pain, dizziness, and a short period of unconsciousness. Surgical decompression had to be performed urgently, because the pericardium could not be punctuated due to the position of the hydatid cyst. The differential diagnosis was cardiac tumor or echinococcal cyst. Because of a negative result of a test for anti-echinococcal antibodies (indirect haemagglutination) and no eosinophilia (5%), the diagnosis of hydatid cyst was at first discarded. Later on, the test for anti-echinococcal antibodies became positive and a marked eosinophilia (59%) was manifest. In combination with a typical appearance in the echocardiograph and NMR, the diagnosis of a cardiac hydatid cyst was made. After preoperative treatment with albendazole, the cyst was sterilized with a 20% NaCl solution and the contents evacuated. The therapy with albendazole was continued. When last seen eight months after the first incidence, the patient was well except some degree of dyspnea on exertion. As a differential diagnosis of a cardiac tumor, a hydatid cyst should be taken into account in patients from an area where Echinococcus granulosus is endemic. A negative test on antiechinococcal antibodies and the absence of eosinophilia do not rule out echinococcosis.


Assuntos
Tamponamento Cardíaco/etiologia , Cardiomiopatias/diagnóstico , Equinococose/diagnóstico , Adulto , Albendazol/administração & dosagem , Anti-Helmínticos/administração & dosagem , Tamponamento Cardíaco/terapia , Cardiomiopatias/terapia , Terapia Combinada , Diagnóstico Diferencial , Diagnóstico por Imagem , Equinococose/terapia , Ventrículos do Coração , Humanos , Masculino
15.
Clin Exp Immunol ; 106(2): 344-50, 1996 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-8918583

RESUMO

Components were isolated from rat liver, sheep lung, rhesus and orang-utan intestine. In enzyme immunoassay, these components detected 57%, 72%, 84% and 88% of human sera containing endomysium and reticulin antibodies (EmA and ARA). At most, 7% of EmA/ARA-negative sera reacted with the antigens. The spectrum of EmA/ARA-positive sera reactive with the various components was different but overlapping. When the antigens of sheep lung and orang-utan intestine were used as a cocktail, 98% of EmA/ARA-positive sera (45/46), but only 2% of control sera (1/46) were detected. The isolated antigens from sheep lung and monkey intestines were able to absorb EmA and ARA from human sera and thus should be suspected to contain the epitopes recognized by EmA and ARA, whereas the rat liver component did not bind. Therefore, the spectrum of autoantibodies in coeliac disease might comprise more than that covered by the terms EmA and ARA. The N-terminal amino acid sequence of some of the antigens was homologous with casein, gliadin, fibrinogen, and collagen.


Assuntos
Autoanticorpos/imunologia , Autoantígenos/imunologia , Autoantígenos/isolamento & purificação , Doença Celíaca/imunologia , Músculo Liso/imunologia , Reticulina/imunologia , Sequência de Aminoácidos , Animais , Autoantígenos/química , Eletroforese em Gel de Poliacrilamida , Ensaio de Imunoadsorção Enzimática/métodos , Esôfago , Gliadina/química , Gliadina/imunologia , Humanos , Imunoglobulina A/análise , Imunoglobulina G/análise , Intestinos/química , Fígado/química , Pulmão/química , Macaca mulatta , Músculo Liso/química , Pongo pygmaeus , Coelhos , Ratos , Reticulina/química , Ovinos
16.
Phys Rev B Condens Matter ; 52(17): 12640-12643, 1995 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-9980424
17.
Z Gerontol ; 26(4): 238-42, 1993.
Artigo em Alemão | MEDLINE | ID: mdl-8212792

RESUMO

The nuclei binding of activated glucocorticoid receptor complexes (GRC) was significantly diminished in old, unstressed rats compared with young ones. In animals killed at different times after physiological stress there were no significant age-dependent differences in nuclei binding of GRC, which recurred in the cytoplasm after 60, 120 and 180 min, resp. Addition of Ca2+ and ATP, resp., to the incubation system increased the nuclei bound part of GRC, especially in young animals. ATP-stimulated translocation promoter (ASTP), isolated from rat liver cytosol, raised the nuclei binding of GRC in both age groups, whereby the increase was only significant in young animals. In cytosol of old rats ASTP were found in a lower concentration; moreover, the reaction between ASTP, GRC, and the template seems to be impaired.


Assuntos
Envelhecimento/genética , Núcleo Celular/fisiologia , Senescência Celular/genética , Citoplasma/fisiologia , Receptores de Glucocorticoides/genética , Trifosfato de Adenosina/fisiologia , Animais , Cálcio/fisiologia , Citosol/fisiologia , Feminino , Expressão Gênica/fisiologia , Regiões Promotoras Genéticas/fisiologia , Ratos , Ratos Wistar , Translocação Genética/fisiologia
19.
Z Gesamte Inn Med ; 46(14): 518-21, 1991 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-1767557

RESUMO

Out of the blood calcium fractions know only the ionized calcium is biologically active. From the height of the total calcium level despite significant dependence no secure conclusion to the Ca++ concentration can be drawn. The level of the total calcium spreads further than that one of the ionized calcium. The up to now used mathematical approaches for the estimation of the blood Ca++ concentration also proved unsuitable; none of them provides a really better statement than the total calcium level. Thus even they represent no acceptable alternative to the Ca++ determination by means of ion-selective electrodes. The investigation by means of ion-selective electrodes. The investigation of various paraclinical sizes (total calcium, total protein, albumin, creatinine, alkaline phosphatase) in a group of patients and a control group in quality and quantity resulted in a different influence on the Ca++ level by the influential factors tested. Only by measurement of the ionized calcium the real actual condition of the calcium homoeostasis can be reflected. Therefore it is no more justified to draw diagnostically and therapeutically relevant consequences from the exclusive determination of the total calcium level.


Assuntos
Proteínas Sanguíneas/metabolismo , Cálcio/sangue , Homeostase/fisiologia , Adulto , Fosfatase Alcalina/sangue , Creatinina/sangue , Feminino , Humanos , Linfoma/sangue , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Transtornos Mieloproliferativos/sangue , Neoplasias/sangue , Paraproteinemias/sangue , Valores de Referência , Albumina Sérica/metabolismo
20.
Ugeskr Laeger ; 153(13): 926-8, 1991 Mar 25.
Artigo em Dinamarquês | MEDLINE | ID: mdl-2024299

RESUMO

A multiaxial diagnostic system (MAS-81) was employed for children referred to the day and inpatient departments for child psychiatry in The University Hospital in Copenhagen during a period of four years (117 children) and from the day and inpatient clinics for child psychiatry in Odense during a period of two years. The total number of children was 145. Clinical aspects are described and compared according to a definite system. A consumer investigation was carried out and this was compared with previous consumer investigations. The consumers expressed satisfaction with work with the multiaxial system. MAS is an employable diagnostic system which is in good agreement with the holistic approach employed by child psychiatrists. Attempts must still be made to improve the system, particularly the axes which register social factors. The system appears to be of value in the choice of correct therapeutic measures.


Assuntos
Psiquiatria Infantil , Transtornos Mentais/diagnóstico , Unidade Hospitalar de Psiquiatria , Psicoterapia/métodos , Criança , Dinamarca , Humanos , Transtornos Mentais/classificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...