Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Phys Eng Express ; 9(2)2023 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-36745910

RESUMO

Purpose: The current prescription and the assessment of the delivered absorbed dose in intraoperative radiation therapy (IORT) with the INTRABEAM system rely mainly on depth-dose measurements in water. The accuracy of this approach is limited because tissue heterogeneity is ignored. It is also difficult to accurately determine the dose delivered to the patient experimentally as the steep dose gradient is highly sensitive to geometric errors. Our goal is to determine the dose to the target volume and the organs at risk of a clinical breast cancer patient from treatment with the system.Methods: A homogeneous water-equivalent CT dataset was derived from the preoperative CT scan of a patient by setting all materials in the patient volume as water-equivalent. This homogeneous CT data represents the current assumption of a homogenous patient, while the original CT data is considered the ground truth. An in-house Monte Carlo algorithm was used to simulate the delivered dose in both setups for a prescribed treatment dose of 20 Gy to the surface of the 3.5 cm diameter spherical applicator.Results: The doses received by 2% (D2%) of the target volume for the homogeneous and heterogeneous geometries are 16.26 Gy and 9.33 Gy, respectively. The D2% for the heart are 0.035 Gy and 0.119 Gy for the homogeneous and heterogeneous geometries, respectively. This trend is also observed for the other organs at risk.Conclusions: The assumption of a homogeneous patient overestimates the dose to the target volume and underestimates the doses to the organs at risk.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Dosagem Radioterapêutica , Neoplasias da Mama/radioterapia , Planejamento da Radioterapia Assistida por Computador , Órgãos em Risco , Método de Monte Carlo
2.
Adv Radiat Oncol ; 6(1): 100593, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33490728

RESUMO

PURPOSE: This study aimed to investigate, in the setting of neoadjuvant gastric irradiation with integrated boost, whether cone beam computed tomography (CBCT)-based adaptive radiation therapy compared with a defined-filling protocol would be beneficial in terms of feasibility and achieving daily reproducible dose volume indexes of the planning target volume (PTV) and organs at risk (OARs) and workflow. METHODS AND MATERIALS: Planning computed tomography (PCT) and 25 CBCT scans of a previously treated patient were used, and neoadjuvant therapy of gastric carcinoma was simulated offline. PTVs and OARs were defined per the TOPGEAR protocol (PTV: 45 Gy/1.8 Gy), and an integrated boost (gross tumor volume [GTV]: 50.4 Gy/2.016 Gy) was added. The patient followed a filling regimen consisting of 12-hour fasting followed by 200 mL of water intake (2 glasses of water) immediately before irradiation. OARs and PTVs were newly contoured on each CBCT. Nonrigid registration of PCT and CBCT scans was performed. Nonadapted plans were recalculated on each CBCT (R-CBCT). Furthermore, an adapted plan was created for the new anatomy (A-CBCT). Dose parameters and comparison of R-CBCT and A-CBCT for the kidneys, liver, and heart were analyzed using a paired t test. RESULTS: A total of 200 plans for R-CBCT and A-CBCT were obtained. Mean gastric volumes were 277.32 cm3 (±54.40 cm3) in CBCT scans and 519.2 cm3 in PCT. Mean doses to the PTV did not differ meaningfully within the CBCT scans, with an average of 1.54%. The D95 improved in GTV coverage by 5.26% compared with the R-CBCT plan. Mean heart, liver, and right kidney doses were reduced with the A-CBCT plan by 35.74%, 10.71% and 29.47%, respectively. The R- and A-CBCT comparison for GTV and OARs was significantly different in all cases (P < .0001). CONCLUSIONS: Adaptive radiation therapy through deformable registration represents an important tool in neoadjuvant gastric irradiation, encompassing daily variability and organ motion, compared with the defined-filling protocol while improving OAR sparing.

3.
Int J Med Robot ; 14(3): e1899, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29484802

RESUMO

OBJECTIVE: Intraoperative radiotherapy (IORT) after surgical resection using a low-kV-X-ray source is a proven method used in cancer treatment. However, the shape and size of the targeted surface area are limited to the size of the available applicators. This can lead to nonconformal and therefore suboptimal treatment for many patients. METHODS: A system is proposed comprising an X-ray source with an applicator for surface irradiation mounted on a robotic arm. This is controlled by an algorithm designed for planning the required continuous path, enabling irradiation of any desired shape with a controlled dose distribution. RESULTS: The system is shown to be capable of irradiating areas composed of rectangles on a flat surface with a homogeneity index of less than 7% inside the targeted area. CONCLUSION: The presented results demonstrate the potential of the proposed setup to eliminate the current limitations, leading to better treatment of patients.


Assuntos
Neoplasias/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Calibragem , Humanos , Robótica , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...