Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Crit Rev Anal Chem ; 52(2): 231-249, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-32715777

RESUMO

The past three decades has seen significant advancements in instrumental detection techniques for both organic and inorganic analytes, leading to more accurate and precise measurements. The relevance of sample preparation prior to instrumental reading cannot be underestimated, and this area has also seen major improvements, with solid phase extraction (SPE) and its miniaturized version (solid phase microextraction, SPME) serving as an efficient clean-up and preconcentration method for analytes. Magnetic nanoparticles (MNPs) belong to the new generation of sorbents, and their characteristic small size and easy manipulation under magnetic field make them ideal materials for extraction of several analytes. This review presents the basic principles of SPE and SPME, and lays more emphasis on different types of MNPs that have been used as efficient separation and preconcentration tools. In addition, application of MNPs for the determination of trace elements in environmental, biological and food samples are well documented in this review.


Assuntos
Nanopartículas de Magnetita , Oligoelementos , Magnetismo/métodos , Extração em Fase Sólida/métodos , Microextração em Fase Sólida
2.
Environ Monit Assess ; 193(10): 627, 2021 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-34487242

RESUMO

Nickel determination is important because of its use in many industrial areas and its negative effects on human health. In this study, an ultraviolet-based photochemical vapor generation (UV-PVG) setup was combined with a T-shaped zirconium-coated slotted quartz tube-atom trapping (T-SQT-AT) apparatus to boost the sensitivity of a flame atomic absorption spectrophotometer for nickel determination. Nickel was separated from the sample matrix by converting it into its volatile species prior to online preconcentration by trapping on the zirconium-coated T-SQT inner surface. Analytical performance was maximized by optimizing all variable conditions. The limit of detection (LOD) and limit of quantification (LOQ) were found as 10 and 33 µg/L, respectively. Daphne tea and lake water samples were analyzed under optimum conditions, and there was no detectable nickel in the samples. For this purpose, spiking experiments were carried out for the samples in order to evaluate the applicability and accuracy of the method. The percent recovery values calculated for the two samples spiked at three different concentrations ranged between 90 and 112%. To our best knowledge, this is the first study in literature where UV-PVG was combined with T-SQT-AT for the determination of nickel in daphne tea and lake water samples prior to FAAS determination.


Assuntos
Daphne , Quartzo , Monitoramento Ambiental , Humanos , Lagos , Níquel/análise , Extratos Vegetais , Espectrofotometria Atômica , Chá , Água/análise , Zircônio
3.
Anal Biochem ; 629: 114309, 2021 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-34270997

RESUMO

This study presents a Fenton digestion method for milk samples based on UV irradiation for cadmium determination using flame atomic absorption spectrometry. The method was developed as an alternative to microwave digesters, using very basic apparatus and easy to acquire chemicals. Fenton digestion process was performed by the help of citric acid coated magnetic nanoparticles. Optimum conditions of the digestion process were applied to milk samples to evaluate analytical performance of the method. Limit of detection and limit of quantification values calculated for cadmium in milk were 0.53 and 1.8 mg/L, respectively. The method was applied to three different milk samples to validate the method's suitability and accuracy. Percent recovery values calculated for the samples spiked at two different concentrations ranged between 86 and 111%. Due to differences in the content of the spiked and control/standard milk samples, exact matrix matching calibration strategy using the same brand of milk sample in the preparation of calibration standard was employed and the accuracy of cadmium quantification was greatly enhanced (≈100%).


Assuntos
Cádmio/análise , Peróxido de Hidrogênio/química , Ferro/química , Nanopartículas de Magnetita/química , Leite/química , Animais , Digestão , Limite de Detecção , Micro-Ondas , Oxirredução , Espectrofotometria Atômica
4.
J Environ Sci Health B ; 55(12): 1041-1047, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32811300

RESUMO

The objective of this study was to determine bixafen and fipronil residues in domestic and industrial wastewater, soil and mint samples by binary dispersive liquid-liquid microextraction method (BDLLME) prior to gas chromatography-mass spectrometry (GC-MS). Extraction efficiency for the selected analytes was improved by optimizing the parameters such as solvent type, ratio and volume, dispersive solvent type/volume, mixing type and duration to increase overall analytical performance. Under the optimum chromatographic and extraction conditions, limits of detection values for bixafen and fipronil were determined as 7.3 and 6.1 µg L-1, respectively. Spiking experiments were performed for domestic and industrial wastewater, soil and mint samples to evaluate applicability and accuracy of the proposed method. Recovery results for the samples were calculated in the range of 89.4%-112.6% via matrix matching calibration strategy. It was determined that the detection power of GC-MS system was improved 7.8 times for bixafen and 119 times for fipronil over LOD comparisons of conventional GC-MS and B-DLLME-GC-MS systems.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Microextração em Fase Líquida/métodos , Resíduos de Praguicidas/análise , Pirazóis/análise , Calibragem , Limite de Detecção , Mentha/química , Poluentes do Solo/análise , Solventes/química , Águas Residuárias/análise , Águas Residuárias/química , Poluentes Químicos da Água/análise
5.
Food Chem ; 319: 126572, 2020 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-32163838

RESUMO

In this study, a molybdenum coated T-shaped slotted quartz tube atom trap flame atomic absorption spectrophotometry method (Mo coated-T-SQT-AT-FAAS) was developed for the determination of cadmium with on-line preconcentration. Inner surface of T-SQT was coated with molybdenum to enhance the trapping efficiency. Hydrogen gas was used instead of organic solvents to release trapped atoms. Limit of detection and quantification were found to be 0.057 and 0.082 µg/L, respectively. The developed method has a linear working range between 0.10 and 1.0 µg/L with a low %RSD value (<3.7). About 1202 times enhancement in detection power was recorded over the conventional FAAS system. Recovery experiments were used to determine the applicability of the method developed to real samples (linden, milk powder and mint) and significant results (94.4-100.7%) were obtained for the samples spiked at 0.30, 0.50 and 1.0 µg/L. The method was also applied to Tomato Leaves 1573a SRM to check the accuracy.


Assuntos
Cádmio/análise , Análise de Alimentos , Alimentos , Molibdênio/química , Espectrofotometria Atômica/métodos , Hidrogênio , Limite de Detecção , Quartzo , Solventes/química
6.
Environ Monit Assess ; 192(1): 61, 2019 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-31865447

RESUMO

Tellurium has been widely used in industrial processes and daily life products, and can cause serious health problems upon exposure. Therefore, determination of tellurium in real-life samples is very crucial. In this study, an accurate, environmentally friendly, and inexpensive analytical method was developed to determine trace levels of tellurium in water samples. To lower the detection limits, system parameters including flame type, acetylene flow rate, slotted quartz tube (T-SQT) height, and trapping period were optimized. Under the optimum conditions, the limit of detection (LOD) and quantification (LOQ) were calculated as 14.1 ng/mL and 47.1 ng/mL, respectively. For recovery studies, the optimized T-SQT-AT-FAAS method was applied to tap water samples to determine trace levels of tellurium and recovery results were found between 91.1 and 111.3%. Relative standard deviation value (%RSD) of the developed method was found to be less than 5.0% even for the lowest concentration in calibration plot, specifying good accuracy and high applicability of the method for water samples. Graphical abstract .


Assuntos
Água Potável/química , Monitoramento Ambiental/métodos , Espectrofotometria Atômica/métodos , Telúrio/análise , Poluentes Químicos da Água/análise , Água Potável/normas , Monitoramento Ambiental/instrumentação , Concentração de Íons de Hidrogênio , Limite de Detecção , Microextração em Fase Líquida/métodos
7.
Food Chem ; 297: 124947, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31253290

RESUMO

Newly developed combination of magnetic cobalt particles based dispersive solid-phase microextraction (Co-MP-DSPME) and slotted quartz tube attached flame atomic absorption spectrometry (SQT-FAAS) was utilized to determine lead at trace levels in tea samples. Co-MPs' adsorbent properties were tested and validated for their selectiveness to lead. Only with a few and short extraction steps (i.e. adding MPs, mixing, decanting and eluting) analyte was extracted from sample solution rapidly and efficiently. Limit of detection (LOD) and limit of quantification (LOQ) for the developed method (Co-MP-DSPME-SQT-FAAS) were found to be 7.77 µg/L and 25.9 µg/L, respectively. Matrix matching strategy was performed and outcomes indicated that the developed method is applicable with the high percent recovery values of 110.1 ±â€¯4.5 and %102.9 ±â€¯4.2 for 100 and 300 µg/kg lead standard spiked black tea samples, respectively. The method was also applied to standard reference material to check the accuracy of the method.


Assuntos
Contaminação de Alimentos/análise , Chumbo/análise , Microextração em Fase Sólida/métodos , Espectrofotometria Atômica/métodos , Chá/química , Cobalto/química , Análise de Alimentos/métodos , Limite de Detecção , Quartzo/química , Sensibilidade e Especificidade , Microextração em Fase Sólida/instrumentação , Espectrofotometria Atômica/instrumentação
8.
Environ Monit Assess ; 191(5): 313, 2019 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-31037521

RESUMO

Determination of cobalt at low concentrations is an important issue because of its potential harmful effects on human health. Although flame atomic absorbance spectrometry (FAAS) is a fast and cheap method, it has high detection limits compared to other methods due to low nebulizer efficiency. In this study, the sensitivity, accuracy, and precision of the conventional FAAS were tried to be improved for cobalt determination using a photochemical vapor generation (PVG) system equipped with a batch type gas-liquid separator (BTGLS). The system parameters including organic acid type and concentration, UV irradiation period, mixing type, atomizer temperature, carrier gas flow rate, and sample volume were optimized to improve the detection power. The limits of detection and quantification were found to be 8.7 and 28.9 µg L-1, respectively. The low relative standard deviation results indicated high precision. Applicability and accuracy of the method to soil samples was determined by recovery studies and percent recoveries were obtained between 98.9-107.0%. Graphical abstract Please provide caption for the graphical abstract.PVG-BT-GLS-AAS system .


Assuntos
Cobalto/análise , Monitoramento Ambiental/métodos , Poluentes do Solo/análise , Solo/química , Espectrofotometria Atômica/métodos , Gases/análise , Humanos , Limite de Detecção
9.
Bull Environ Contam Toxicol ; 102(1): 122-127, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30470949

RESUMO

Antimony is known to have some adverse health effects on human health. Flame atomic absorption spectrometry (FAAS) is a widely used instrumental for the determination of antimony and other metals. However, it lacks the sensitivity to determine these metals at trace levels. This study was aimed at overcoming this setback by using hydrogen assisted T-shaped slotted quartz tube technique to preconcentrate and determine antimony by FAAS. All the system parameters were optimized to enhance the detection power of the system. Under the optimum experimental conditions, the limits of detection and quantification were found to be 0.75 and 2.49 µg L-1, respectively with R2 value of 0.9999. Accuracy of the developed method was validated by experimental results agreeing to the certified value of a standard reference material. Recovery studies were also carried out to determine the method's applicability to tap and mineral water samples, and the results obtained were appreciable.


Assuntos
Antimônio/análise , Quartzo/química , Espectrofotometria Atômica , Hidrogênio/química , Limite de Detecção , Sensibilidade e Especificidade
10.
Bull Environ Contam Toxicol ; 100(5): 715-719, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29411047

RESUMO

In this study, dispersive liquid-liquid microextraction was systematically optimized for the preconcentration of nickel after forming a complex with diphenylcarbazone. The measurement output of the flame atomic absorption spectrometer was further enhanced by fitting a custom-cut slotted quartz tube to the flame burner head. The extraction method increased the amount of nickel reaching the flame and the slotted quartz tube increased the residence time of nickel atoms in the flame to record higher absorbance. Two methods combined to give about 90 fold enhancement in sensitivity over the conventional flame atomic absorption spectrometry. The optimized method was applicable over a wide linear concentration range, and it gave a detection limit of 2.1 µg L-1. Low relative standard deviations at the lowest concentration in the linear calibration plot indicated high precision for both extraction process and instrumental measurements. A coal fly ash standard reference material (SRM 1633c) was used to determine the accuracy of the method, and experimented results were compatible with the certified value. Spiked recovery tests were also used to validate the applicability of the method.


Assuntos
Poluentes Ambientais/análise , Níquel/análise , Espectrofotometria Atômica/métodos , Poluentes Ambientais/química , Concentração de Íons de Hidrogênio , Microextração em Fase Líquida/métodos , Níquel/química , Quartzo/química
11.
Environ Monit Assess ; 189(6): 277, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28527034

RESUMO

The need to enhance food safety has led to major advancements in pesticide productions, and though many benefits have been gained, environmental contamination has also risen from these chemicals that tend to persist in the environment. Some pesticides, together with other chemicals commonly called endocrine disruptor compounds, block the receptor sites of hormones or mimic displaced hormones, leading to imbalanced hormonal levels that result in health disorders and diseases. These chemicals occur at trace levels and are not directly detected by conventional analytical methods. A dispersive liquid-liquid microextraction method was therefore developed for preconcentration of 12 analytes including hormones, endocrine disruptor compounds, and pesticides, to be analyzed by gas chromatography mass spectrometry. This was achieved by optimizing parameters such as extractor solvent type and amount, dispersive solvent type and amount, pH, and salt effect that affect extraction output. The limits of detection and quantification of the developed method were between 0.09 and 3.36 and 0.31 and 11.19 ng mL-1, respectively. The calibration plots of the analytes also showed good linearity and low percent relative standard deviations. Recovery studies were performed for tap water and wastewater samples, and the percent recoveries recorded were between 84 and 109%.


Assuntos
Disruptores Endócrinos/análise , Monitoramento Ambiental/métodos , Poluentes Químicos da Água/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Microextração em Fase Líquida/métodos , Praguicidas/análise , Solventes/química , Águas Residuárias/química , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...