Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Talanta ; 273: 125877, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38460420

RESUMO

Pillar[n]arenes (P[n]A, n = 5-10) have attracted much attention because of their highly symmetric pillar-shaped architecture with π-electron rich cavity. Nevertheless, the use of ionic liquid functionalized P[n]A in chromatography has not been reported up to data. This work reports the investigation of the imidazolium ionic liquids functionalized pillar[6]arene (P6A-C10-IM-C8[NTf2]) as the stationary phase for gas chromatography (GC). The statically coated P6A-C10-IM-C8[NTf2] column (0.25 mm i.d.) showed moderate polarity and high column efficiency of 4733 plates/m determined by n-dodecane at 120 °C (k = 2.29). Owing to its unique amphiphilic conformation, the P6A-C10-IM-C8[NTf2] showed good column inertness and resolving capability for a wide range of analytes and isomers. Particularly, the P6A-C10-IM-C8[NTf2] column exhibited distinctly advantageous performance for the challenging isomers of halogenated benzenes, benzaldehydes, phenols and anilines over the common commercial columns, namely 5% phenyl methyl polysiloxane (HP-5) and 35% phenyl methyl polysiloxane (HP-35). In addition, it exhibited good column repeatability and reproducibility with RSD values on the retention times less than 0.05% for run-to-run, 0.38% for day-to-day and 2.94% for column-to-column, respectively. This work demonstrates the promising future of ionic liquid P[n]A stationary phases for chromatographic separations.

2.
Anal Bioanal Chem ; 416(6): 1321-1335, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38231255

RESUMO

This work presents the first example of the utilization of polar ester group functionalized pillar[6]arene (P6A-C10-OAc) as a stationary phase for capillary gas chromatographic (GC) separations. The statically coated P6A-C10-OAc column showed a high column efficiency of 5393 plates/m and moderate polar nature. Its resolving capability and retention behaviors were investigated for a mixture of 20 analytes and more than a dozen isomers from apolar to polar in nature. As evidenced, the P6A-C10-OAc column achieved high-resolution separations of all the analytes and good inertness. Importantly, it exhibited distinctly advantageous performance for high resolution of the challenging isomers of xylenes, diethylbenzenes, ethyltoluenes, and halobenzenes over the commercial HP-5 (5% phenyl dimethyl polysiloxane), HP-35 (25% phenyl dimethyl polysiloxane), and PEG-20M (polyethylene glycol) columns.

3.
Chem Biodivers ; 21(3): e202301795, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38268034

RESUMO

This work reports the first example of employing ester-functionalized pillar[5]arene (P5A-C10-OAc) stationary phase for gas chromatography (GC) separations. The as-fabricated P5A-C10-OAc column achieved improved column efficiency of 4270 plates/m and separation performance in contrast to the P5-C10-Br column. The P5A-C10-OAc column showed good separation performance for a wide range of analytes such as alkanes, bromoalkanes, ketones, fatty acid methyl esters, aldehydes, alcohols, halobenzenes, anilines, phenols, naphthalenes, and showed sharp and symmetrical peak shapes for analytes that are liable to peak-tailing in GC analysis. As testified by the challenging isomer mixtures (bromonitrobenzene, chloronitrobenzene, bromobenzaldehyde, chlorobenzaldehyde, nitrobenzaldehyde), the P5A-C10-OAc column exhibited comprehensively higher separation capability than the P5A-C10-Br, P5A-C10 and commercial HP-35 columns. This work demonstrates the great potential of pillararene-based stationary phases as a new type of stationary phases for GC separations.


Assuntos
Álcoois , Compostos de Anilina , Reprodutibilidade dos Testes , Cromatografia Gasosa/métodos , Compostos de Anilina/química , Isomerismo
4.
Anal Chim Acta ; 1291: 342221, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38280782

RESUMO

BACKGROUND: Gas chromatography is worldwide recognized as one of the most important analytical techniques, due to its high versatility and reliability. The heart of a gas chromatograph is the column, that allows analyte peak separations and, consequently, accurate qualitative and qualitative analyses. New and more efficient columns are always requested to satisfy new and challenging analytical needs. RESULTS: In this work, imidazolium ionic liquids functionalized pillar [5] arenes have been used for the first time as gas chromatographic stationary phases, considering their highly symmetric pillar-shaped architecture with cavities rich in π-electrons. Four imidazolium ionic liquids functionalized pillar [5] arenes have been tested as stationary phases with numerous analytes and isomers. In particular, one of these showed superior performances if compared to commercial columns, enabling challenging isomeric separations of halogenated benzenes, aromatic aldehydes, and aromatic anilines. SIGNIFICANCE AND NOVELTY: To our knowledge, this is the first report on the use of the ionic liquid P[n]A as a stationary phase in chromatography, either in GC or liquid chromatography (LC) separations. This work demonstrates the promising potential of ionic liquid P[n]A stationary phases for chromatographic separations.

5.
Analyst ; 149(3): 925-934, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38192226

RESUMO

Here we report the first example of employing hydroxyl-functionalized pillar[5]arene (P5A-C10-OH) as stationary phase for capillary gas chromatographic (GC) separations. The statically coated P5A-C10-OH capillary column possessed moderate polarity and column efficiency of 3233 plates per m determined by n-dodecane. As a result, the P5A-C10-OH column exhibited high-resolution capability for the mixture of 17 analytes from apolar to polar nature. Importantly, it exhibited advantageous performance for high resolution of the challenging isomers of bromonitrobenzene, chloroaniline, bromoaniline, iodoaniline and dimethylaniline with good peak shapes over the P5A-C10 and commercial HP-35 columns. In addition, eight cis-/trans-isomers with diverse types were baseline separated on the P5A-C10-OH column. And the application of detecting isomeric impurities in real samples gave strong evidence of its potential and feasibility for the viable GC analysis.

6.
Chem Biodivers ; 20(8): e202300350, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37377049

RESUMO

This work firstly reported a new polycaprolactone based material functionalized with guanidinium ionic liquid (PCL-GIL) as the stationary phase with high resolution performance for capillary gas chromatography (GC). It is composed of polycaprolactone (PCL) and guanidinium ionic liquid (GIL) with amphiphilic conformation. The PCL-GIL capillary column coated by static method exhibited high column efficiency of 3942 plates/m and moderate polarity. As a result, the PCL-GIL column exhibited high-resolution capability. For a mixture of 27 analytes with a wide ranging polarity and outperformed the PCL-2OH and HP-35 columns, showing its advantageous separation capability for analytes of diverse types. Moreover, the PCL-GIL column showed high resolving capability for various positional isomers and cis-/trans-isomers, including alkylbenzenes, chlorobenzenes, naphthalenes, bromonitrobenzenes, chloronitrobenzenes, benzaldehydes, phenols, alcohols, respectively. In a word, PCL derivatized by GIL units as a new type of stationary phase has a promising future in GC separations.


Assuntos
Líquidos Iônicos , Guanidina , Reprodutibilidade dos Testes , Cromatografia Gasosa/métodos
7.
Anal Chim Acta ; 1251: 340979, 2023 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-36925280

RESUMO

The separation of aromatic isomers, in particular xylene isomers, represents a big issue in chemical and petroleum industries, owing to their similar molecular sizes and boiling points. In this work, the investigation ofpillar[6]arene derivative modified by long alkyl chains (P6A-C10) as a stationary phase for high-resolution gas chromatographic (GC) separations of xylene isomers is presented. Pillar[n]arenes are a new class of macrocyclic hosts that can accommodate specific guests due to their highly symmetrical and rigid pillar architectures with π-electron rich cavities. The P6A-C10 column showed high-resolution performance towards xylene isomers, with peculiar advantages if compared with the commercial HP-5, HP-35, DB-17, and PEG-20Mcolumns.A quantum chemistry calculation has been performed, showing a difference in non-covalent interactions with the P6A-C10 pillar framework, which leads to specific selectivity for xylene isomers.Furthermore, the P6A-C10 column exhibited good repeatability.

8.
ACS Appl Mater Interfaces ; 14(50): 56132-56142, 2022 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-36472861

RESUMO

In this work, the fabrication, synthesis, and characterization of a new stationary phase based on an amphiphilic pillar[6]arene (P6A-C10-2NH2) for gas chromatographic analyses are reported. The gas chromatography (GC) column prepared with P6A-C10-2NH2 stationary phase exhibited a medium polarity, an efficiency of 3219 plates/m, and unmatched resolving capabilities toward chloroaniline, bromoaniline, iodoaniline, and toluidine isomers. Furthermore, the P6A-C10-2NH2 column showed excellent repeatability with maximum relative standard deviations equal to 0.02, 0.07, and 2.56% for run-to-run, day-to-day, and column-to-column, respectively, demonstrating a great potential as a new stationary phase in separation science.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...